background image

PLFY-4

PLFY-P-NCMU-ER4, -NBMU-E2 (November 2015)

© 2015 Mitsubishi Electric US, Inc.

Model

PLFY-P08NBMU-E2 *3

PLFY-P12NBMU-E2

PLFY-P15NBMU-E2

PLFY-P18NBMU-E2

Power source

1-phase 208-230 V 60Hz

Cooling capacity *1

 

(Nominal)

Btu/h

8,000 

12,000 

15,000 

18,000 

kW 

2.4

3.5 

4.4 

5.3 

Power input

kW 

0.03 

0.03 

0.03 

0.04 

Current input

0.31 

0.31 

0.31 

0.33 

Heating capacity *2

 

(Nominal)

Btu/h

9,000 

13,500 

17,000 

20,000 

kW 

2.7

4.0 

5.0 

5.9 

Power input

kW 

0.02 

0.02 

0.02 

0.03 

Current input

0.24 

0.24 

0.24 

0.26 

External finish

Galvanized steel sheet

External dimension H x W x D

in.

10-3/16 x 33-3/32 x 33-3/32

mm

258 x 840 x 840

Net weight

lbs (kg)

51 (23)

Decoration 

panel

Model

PLP-40BAU

External finish

Munsell No. (6.4Y 8.9/0.4)

Dimension 

H x W x D

in.

1-3/8 x 37-13/32 x 37-13/32

mm

35 x 950 x 950

Net Weight

lbs (kg)

13 (6)

Heat exchanger

Cross fin

FAN

Type x Quantity

Turbo fan x 1

External static 

pressure

in.WG

 0.000 (208V)

Pa

0

in.WG

0.000 (230V)

Pa

0

Motor type

DC motor

Driving mechanism

Direct-driven

Airflow rate (Low-

Mid2-Mid1-High)

CFM

494 - 530 - 547 - 565

494 - 530 - 547 - 565

494 - 530 - 547 - 565

494 - 530 - 565 - 636

m3 / min

14.0 - 15.0 - 15.5 - 16.0 14.0 - 15.0 - 15.5 - 16.0 14.0 - 15.0 - 15.5 - 16.0 14.0 - 15.0 - 16.0 - 18.0

L / s

233 - 250 - 259 - 267

233 - 250 - 259 - 267

233 - 250 - 259 - 267

233 - 250 - 267 - 300

Sound pressure level  (Low-Mid2-Mid1-High)

 

(measured in anechoic room)

dB <A>

27 - 29 - 30 - 31(208-

230V)

27 - 29 - 30 - 31(208-

230V)

28 - 29 - 30 - 31(208-

230V)

28 - 29 - 30- 32(208-

230V)

Insulation material

PS

Air filter 

PP honeycomb (long life filter, anti-bacterial type)

Protection device 

Fuse

Refrigerant control device 

LEV

Connectable outdoor unit 

R410A CITY MULTI

Diameter of 

refrigerant pipe 

(O.D.) 

Liquid (R410A)

in. (mm) 

1/4 (6.35) Flare

Gas (R410A)

 

        

in. (mm)

1/2 (12.7) Flare

Field drain pipe size

in. (mm)  

O.D. 1-1/4(32)

Drain lift mechanism

in. (mm)

33-7/16 (850)

Standard 

attachment

Document  

Accessory 

Installation Manual, Instruction Book

Optional parts

External heater adapter

CN24RELAY-KIT-CM3

Air outlet shutter plate

PAC-SH51SP-E

High efficiency filter element 

 

(MERV 10)

PAC-SH59KF-E

Multi-function casement

PAC-SH53TM-E

i-see sensor corner panel

PAC-SA1ME-E

Flange for fresh air intake

PAC-SH65OF-E

Wireless signal receiver

PAR-SA9FA-E

Remark

Installation

Details on foundation work, duct work, insulation work, electrical wiring, 

power source switch, and other items shall be referred to the Installation 

Manual.

Ventilation Air: Providing sufficient ventilation air is an important part of every building design.

ASHRAE standard 62 provides the minimum ventilation air requirements. Also check local 

codes.

1. SPECIFICATIONS

Note:

*1 Nominal cooling conditions 

*2 Nominal heating conditions 

Unit converter

Indoor: 

80degF D.B. / 67degF W.B. 

(26.7degC D.B. / 19.4degC W.B.)

70degF D.B. (21.1degC D.B.)

kcal/h = kW x 860 

BTU/h = kW x 3,412 

Outdoor: 

95degF D.B. (35degC D.B.)

47degF D.B. / 43degF W.B. 

(8.3degC D.B. / 6.1degC W.B.)

cfm = m3/min x 35.31 

lbs = kg / 0.4536

Pipe length: 

25 ft. (7.6 m)

25 ft. (7.6 m)

*Above specification data is subject to 

rounding variation. 

Level difference: 

0 ft. (0 m)

0 ft. (0 m)

*Due to continuing improvement, above specification may be subject to change without notice. 

 

*3 PLFY-P08NBMU-E2 is not compatible with PUMY-P**NHMU/NKMU outdoor units.

PLFY-P08NBMU-E2, PLFY-P12NBMU-E2, PLFY-P15NBMU-E2, PLFY-P18NBMU-E2

Содержание PLFY-P08NCMU-ER4

Страница 1: ...S PLFY 12 6 1 Temperature Distributions PLFY 12 6 2 Airflow Distributions PLFY 15 6 3 Branch Duct Capacities PLFY 18 7 VENTILATION AIR INTAKE AMOUNT AND STATIC PRESSURE PLFY 25 7 1 PLFY P08 12 15NCMU...

Страница 2: ...hment Allowing long piping and versatility The PLFY not only brings outside air into your space but the PLFY P NBMU E2 can also branch over to air condition an adjacent room Drain water lifted to 33 7...

Страница 3: ...Air filter Polypropylene honeycomb fabric Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A R22 CITY MULTI Diameter of refrigerant pipe O D Liquid R410A in mm 1 4 6...

Страница 4: ...n device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Diameter of refrigerant pipe O D Liquid R410A in mm 1 4 6 35 Flare Gas R410A in mm 1 2 12 7 Flare Field drain pip...

Страница 5: ...erant control device LEV Connectable outdoor unit R410A CITY MULTI Diameter of refrigerant pipe O D Liquid R410A in mm 3 8 9 52 Flare Gas R410A in mm 5 8 15 88 Flare Field drain pipe size in mm O D 1...

Страница 6: ...ls Air intake grille 2 5 32 55 1 3 8 35 1 3 8 35 2 5 32 55 Auto vane Grille Air intake hole Air intake hole Air outlet hole Air outlet hole 11 27 32 301 11 27 32 301 14 27 32 377 14 27 32 377 25 19 32...

Страница 7: ...e attached flexible pipe or socket I D 1 26 Integrated lift pump outlet PVC pipe O D 1 26 Suspension bolt M10 or W3 8 Branch duct hole Fresh air intake hole Branch duct hole Ceiling hole Suspension bo...

Страница 8: ...LFY P36NBMU E2 X Y Z mm in Model name Refrigerant pipe side Refrigerant pipe Refrigerant pipe side Refrigerant pipe Refrigerant pipe side Refrigerant pipe PLFY P08 12 15NCMU ER4 PLFY P12 15 18 24 30 3...

Страница 9: ...VANE MOTOR FAN MOTOR WITH THERMAL FUSE CAPACITOR FAN MOTOR C1 PIPE TEMPERATURE DETECTION LIQUID MA REMOTE CONTROLLER LED2 LED1 3 1 1 3 CND POWER YLW 2 1 YLW1 3 BLU D U M CNC D HEATER RED ORN FUSE ZNR...

Страница 10: ...ON HEAT DOWN EMERGENCY OPERATION COOL UP SYMBOL NAME NAME LED on indoor board for service CN24 SYMBOL NAME MT I SEE SENSOR MOTOR CN105 IT TERMINAL 32 F 15k 77 F 5 4k 32 F 15k 77 F 5 4k 32 F 15k 77 F 5...

Страница 11: ...125 250 500 1k 2k 4k 8k Octave band center frequencies Hz PLFY P08 12NBMU E2 External Static Pressure 0Pa 0 00 in WG Power Source 208 230V 60Hz 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 0 50 0 55 0 60 0 6...

Страница 12: ...TRIBUTIONS Ref PLFY NCMU E_TPD_USDB_70 PLFY P08 12 15 NCMU ER4 2 7 8 8 Height m ft Floor distance m ft 2 6 6 1 3 3 3 9 8 2 6 6 1 3 3 0 0 21 70 23 73 25 77 25 77 Floor distance m ft 0 0 35 95 27 81 23...

Страница 13: ...2 6 6 1 3 3 1 3 3 0 Height m ft Floor distance m ft Floor distance m ft Height m ft C F C F PLFY P12 15NBMU E2 Cooling mode Standard Flow angle 30 4 way flow ceiling height 2 7 m 8 9ft Heating mode S...

Страница 14: ...2 m 10 4ft 4 13 1 4 13 1 3 9 8 3 9 8 1 3 3 2 6 6 2 6 6 1 3 3 0 0 2 7 8 9 2 0 6 6 1 0 3 3 0 2 7 8 9 2 0 6 6 1 0 3 3 4 13 1 3 9 8 4 13 1 3 9 8 2 6 6 2 6 6 1 3 3 1 3 3 0 Height m ft Floor distance m ft...

Страница 15: ...Ref PLFY NCMU E_AFD_USDB Fan mode Flow angle 30 Fan mode Flow angle 70 Height m ft Floor distance m ft Floor distance m ft 0 0 m s ft s m s ft s Height m ft 0 0 PLFY P08 12 15 NCMU ER4 2 7 2 1 2 7 8...

Страница 16: ...2 6 6 2 6 6 1 3 3 1 3 3 0 Height m ft Floor distance m ft Floor distance m ft Height m ft m s ft s m s ft s PLFY P12 15NBMU E2 Cooling mode Flow angle 30 Heating mode Flow angle 60 0 2 7 8 9 2 0 6 6 1...

Страница 17: ...s ft s PLFY P24 30NBMU E2 Cooling mode Flow angle 30 Heating mode Flow angle 60 5 16 4 4 13 1 4 13 1 3 9 8 3 9 8 5 16 4 2 6 6 2 6 6 1 3 3 1 3 3 0 5 16 4 4 13 1 4 13 1 3 9 8 3 9 8 5 16 4 2 6 6 2 6 6 1...

Страница 18: ...PLFY 18 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 3 Branch Duct Capacities 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 19: ...PLFY 19 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 20: ...PLFY 20 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 21: ...PLFY 21 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 22: ...PLFY 22 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 23: ...PLFY 23 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 24: ...PLFY 24 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc 6 TEMPERATURE AIRFLOW DISTRIBUTIONS...

Страница 25: ...t characteristics at site Q A E C 2 Q Qa A D 3 CFM in W G 10 2 in W G 10 2 in W G 10 2 in W G 10 2 in W G 10 2 NOTE Fresh air intake amount should be 20 or less of How to read curves Refrigerant pipe...

Страница 26: ...ic pressure Pa in W G 10 2 200 80 150 60 100 40 50 20 50 20 0 2 50 100 150 200 250 CFM 4 8 CMM 6 Airflow rate Static pressure Pa in W G 10 2 Q 0 B A C 1 Curve in the graphs Duct characteristics at sit...

Страница 27: ...nal heater adapter PLFY P NBMU E2 CN24RELAY KIT CM3 PAC SA9FA E PAC SH65OF E Air outlet shutter plate Multi function casement High efficiency filter element PLFY P NBMU E2 PAC SH51SP E PAC SH53TM E PA...

Страница 28: ...r outlet to modify the air way from 4 to 3 or 2 With 1 PAC SH51SP E 4 air ways can be changed to 3 With 2 PAC SH51SP E 4 air ways can be changed to 2 Changing to 1 way is not allowed Material Foamed p...

Страница 29: ...n Manual 8 2 High Efficiency Filter Element PAC SH59KF E MERV 10 for PLFY P NBMU E2 8 OPTIONAL PARTS 8 3 Multi function Casement PAC SH53TM E for PLFY P NBMU E2 Multi function casement is used for Hig...

Страница 30: ...nsor corner panel Quantity 1 Shape 2 Plastic fastener 2 Detailed installation information should be referred to its Installation Manual 8 4 i see Sensor Corner Panel PAC SA1ME E for PLFY P NBMU E2 8 O...

Страница 31: ...inch duct The flange for fresh air intake is installed in the Multi function casement PAC SH53TM E or indoor unit Item 1 Duct flange Quantity 1 Shape 2 Insulator 1 3 Screw 3 M4x10 Detailed installati...

Страница 32: ...nsumption 0 9W or less The length of the electrical wiring for the CN24RELAY KIT CM3 is 2 meters 6 1 2 ft To extend this length use sheathed 2 core cable Control cable type CVV CVS CPEV or equivalent...

Страница 33: ...PLFY 33 PLFY P NCMU ER4 NBMU E2 November 2015 2015 Mitsubishi Electric US Inc...

Отзывы: