![Mitsubishi PD-5030 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/mitsubishi/pd-5030/pd-5030_service-manual_1809393006.webp)
2-4
does not get any shock or stress.
(7)
If one touches the connector of the flexible cable exposed to the rear side of the PDP module, there is
danger of causing a poor contact. As such, it must be handled with utmost care. In addition, the flexible
cable is very weak in mechanical strength. Therefore, this cable must not be touched during handling.
(8)
The panel surface of the filter and the PDP module is easy to be hurt. These components should be
handled very carefully not to press or rub them with a hard thing. Never put them on a hard thing with the
panel surface faced downwards.
(9)
When the panel surface of the PDP module is contaminated, gently wipe off the contaminant with a piece
of soft dry cloth. Liquid-state contamination can be removed by lightly pressing it, without rubbing it. If it is
difficult to remove the contamination, use a piece of cloth soaked with a neutral detergent. The cloth for
wiping off should be clean. Never use the same cloth repeatedly. If a cleansing detergent or water drops
should enter the module interior or be attached to the module surface other than the display plane at the
time of cleaning, this will give rise to the destruction of the product when the product is energized.
(10) Refer to the “Instruction Manual” in regard to contamination in the filter and the cabinet.
(11) When transporting this product, use the packing materials specified in the list of parts. Once used, such
packing materials should not be used again.
(12) This product is composed of a variety of parts, such as those made of materials like glass, metal, plastics,
etc., and those like a lithium battery (circuit symbol of the MAIN PWB: BA9501), etc. Therefore, when
abandoning this product, this should be done in accordance with the relevant law of the nation or an
autonomous body.
Содержание PD-5030
Страница 19: ...3 13 The PDP is fault Block defect All white signal All white signal All white signal All white signal...
Страница 24: ...3 18...
Страница 25: ...AUDIO PWB 3 19...
Страница 26: ...232C PWB CTL PWB PWR PWB LED PWB SENB PWB SENC PWB SEND PWB M2003 pin 3 M2003 pin 2 M2004 pin 3 3 20...
Страница 31: ...2 STAND 1 SCREW M6 50 4p 2 STAND 5 2...
Страница 33: ...2 M50 BACK COVER 1 M36 BARRIER PS 5 4 Adhesion should be based on the position of heat radiator holes...
Страница 40: ...10 STAND modification 1 SCREW M6 50 4p 5 11...
Страница 49: ...18 POWER UNIT 1 SRW14 PL CPIMS 4 12 15KF 6p 2 PSU POWER UNIT 3S110171 5 20...
Страница 53: ...22 WIRE CLAMP M06 CLAMP MWC 2S 19p P CLAMP WS 2W V0 16p 5 24...