![Mitsubishi PD-5030 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/mitsubishi/pd-5030/pd-5030_service-manual_1809393020.webp)
3-14
Make the setting of OFF
→
ON for
the main power supply.
Does the priming glimpse?
When the AD connector is dis-
connected, is the LVDS signal
normally output to each pin of the
AD connector? (For more details
of the signal, refer to the descrip-
tions about the connector pins.)
The PDP is fault.
YES
No picture is displayed.
NO
(8) No pictures
[(Caution) The voltage outputs of Vs = 170V and Vd = 64V, 5Vdc are always generated, but the LED is
not flashing or lighting for alarming. However, the voltage values can differ according to the PDP.]
The AD connector or the PDP is
fault.
YES
The MAIN PWB is fault.
NO