![Mitsubishi PD-5030 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/mitsubishi/pd-5030/pd-5030_service-manual_1809393014.webp)
3-8
2. Image errors
(Caution) Typical abnormal images are shown below. All errors do not always fall on these error samples.
(1) Image burn and deterioration in brightness
This is not a fault.
Residual images are seen with-
out signal entry.
This is not a fault.
Deterioration in brightness
(2) Failure in writing
The PDP is fault.
Failure in writing
A
Dot errors change
with no continuity.
All-white signal
All-white signal
All-white signal
No signal
Содержание PD-5030
Страница 19: ...3 13 The PDP is fault Block defect All white signal All white signal All white signal All white signal...
Страница 24: ...3 18...
Страница 25: ...AUDIO PWB 3 19...
Страница 26: ...232C PWB CTL PWB PWR PWB LED PWB SENB PWB SENC PWB SEND PWB M2003 pin 3 M2003 pin 2 M2004 pin 3 3 20...
Страница 31: ...2 STAND 1 SCREW M6 50 4p 2 STAND 5 2...
Страница 33: ...2 M50 BACK COVER 1 M36 BARRIER PS 5 4 Adhesion should be based on the position of heat radiator holes...
Страница 40: ...10 STAND modification 1 SCREW M6 50 4p 5 11...
Страница 49: ...18 POWER UNIT 1 SRW14 PL CPIMS 4 12 15KF 6p 2 PSU POWER UNIT 3S110171 5 20...
Страница 53: ...22 WIRE CLAMP M06 CLAMP MWC 2S 19p P CLAMP WS 2W V0 16p 5 24...