3-17
Is there a 0Vdc output at Pin 12 of the RS con-
nector?
Is there a signal output specified below at Pin
6 of the PW connector?
When the RS connector is disconnected, is
there a 0Vdc output at Pin 12 of the RS con-
nector in the MAIN PWB?
YES
The wireless remote control is not
effective.
NO
NO
Is there a signal output specified below at Pin
1 of the LD connector?
(2) The wireless remote control is not effective.
(Caution) Since the detection of “wired” or “wireless” is conducted for the remote control through the remote terminal,
it is necessary to pull out the remote control cable from the remote terminal, without fail. Troubleshooting
should be carried out after confirming that “IR REMOTE” is set at ON and that “ID NUMBER” is at ALL
according to the user’s menu.
The LED connector or the LED PWB is fault.
YES
The 232C PWB or the RS con-
nector is fault.
YES
The MAIN PWB is fault.
YES
5Vp-p
5Vp-p
The PW connector or the PWR
PWB is fault.
YES
NO
3-19
Содержание PD-5030
Страница 19: ...3 13 The PDP is fault Block defect All white signal All white signal All white signal All white signal...
Страница 24: ...3 18...
Страница 25: ...AUDIO PWB 3 19...
Страница 26: ...232C PWB CTL PWB PWR PWB LED PWB SENB PWB SENC PWB SEND PWB M2003 pin 3 M2003 pin 2 M2004 pin 3 3 20...
Страница 31: ...2 STAND 1 SCREW M6 50 4p 2 STAND 5 2...
Страница 33: ...2 M50 BACK COVER 1 M36 BARRIER PS 5 4 Adhesion should be based on the position of heat radiator holes...
Страница 40: ...10 STAND modification 1 SCREW M6 50 4p 5 11...
Страница 49: ...18 POWER UNIT 1 SRW14 PL CPIMS 4 12 15KF 6p 2 PSU POWER UNIT 3S110171 5 20...
Страница 53: ...22 WIRE CLAMP M06 CLAMP MWC 2S 19p P CLAMP WS 2W V0 16p 5 24...