background image

15

9.4. Installing the grille

9.4.1. Preparations (Fig. 9-5)

• Install the two enclosed screws with washer 

2

 in the main unit (at the corner drain

pipe area and at the opposite corner) as shown in the diagram.

Fig. 9-5

19/32 to 25/32

A

B

9.3. Selection of the air outlets

For this grille the discharge direction is available in 11 patterns. Also, by setting the
Remote controller to the appropriate settings, you can adjust the air-flow and speed.
Select the required settings from the Table according to the location in which you
want to install the unit.
1) Decide on the discharge direction pattern.
2) Be sure to set the remote contoller to the appropriate settings, according to the

number of air outlets and the height of the ceiling on which the unit will be in-
stalled.

Note:
For 3 and 2-directional, please use the air outlet shutter plate (option).

4-directional

3-directional

One pattern:

4 patterns:

Factory setting

One air outlet fully closed

2-directional

6 patterns:
Two air outlet fully closed

Blowout

direction

patterns

Blowout

direction

patterns

9.1. Checking the contents (Fig. 9-1)

• This kit contains this manual and the following parts.

Accessory name

Q’ty

Remark

1

Grille

1

950 

×

 950 (mm), 37 - 3/8 

×

 37 - 3/8 inch

2

Screw with captive washer

4

M5 

×

 0.8 

×

 25

3

Gauge

1

(Divided into four parts)

4

Fastener

2

5

Screw

4

×

 8

6

Wired remote controller

1

for PLP-42AAMD

9. Installing the grille

1

4

5

6

ø

20

2

3

Fig. 9-1

Fig. 9-2

A

D

C

B

A=11/16

+3/16

  0

Fig. 9-3

B

A

C

1

1

D

E

2

F

G

F

B

1

9.2. Preparing to attach the grille (Fig. 9-2)

• With the gauge 

3

 supplied with this kit, adjust and check the positioning of the unit

relative to the ceiling. If the unit is not properly positioned relative to the ceiling, it
may allow air leaks or cause condensation to collect.

• Make sure that the opening in the ceiling is within the following tolerances:

860 

×

 860 - 910 

×

 910 mm, 33 - 7/8 

×

 33 - 7/8 to 35 - 13/16  

×

  35 - 13/16 inch.

• Make sure that step A is performed within 17-22 mm, 11/16-7/8 inch. Damage

could result by failing to adhere to this range.

A

Main unit

B

Ceiling

C

Gauge 

3

 (inserted into the unit)

D

Ceiling opening dimensions

9.2.1. Removing the intake grille (Fig. 9-3)

• Slide the levers in the direction indicated by the arrow 

1

 to open the intake grille.

• Unlatch the hook that secures the grille.

* Do not unlatch the hook for the intake grille.

• With the intake grille in the “open” position, remove the hinge of the intake grille

from the grille as indicated by the arrow 

2

.

9.2.2. Removing the corner panel (Fig. 9-4)

• Remove the screw from the corner of the corner panel. Slide the corner panel as

indicated by the arrow 

1

 to remove the corner panel.

A

Intake grille

B

Grille

C

Intake grille levers

D

Grille hook

E

Hole for the grille’s hook

F

Corner panel

G

Screw

Fig. 9-4

8. System control

Refer to the outdoor unit installation manual.

A

Main unit

B

Screw with
captive washer

 BG79U795H01_en.pm6

05.12.1, 9:48 AM

15

Содержание Mr.Slim PLA-A

Страница 1: ...rrect use read this manual and the outdoor unit installation manual thoroughly before installing the air conditioner unit MANUAL DE INSTALACI N Para un uso correcto y seguro lea detalladamente este ma...

Страница 2: ...edical equipment and radio communications equipment can cause the air conditioner to malfunction or breakdown The air conditioner may also affect medical equipment disturbing medical care and communic...

Страница 3: ...the field Install securely ensuring that there is no clearance between the ceiling panel grille and between the main unit grille A Outer side of main unit B Bolt pitch C Ceiling opening D Outer side o...

Страница 4: ...mm 11 16 7 8 inch Damage could result by failing to adhere to this range Fig 3 7 Caution Use the top half of the box as a protective cover to prevent dust or debris from getting inside the unit prior...

Страница 5: ...Connecting pipes Fig 4 1 When commercially available copper pipes are used wrap liquid and gas pipes with commercially available insulation materials heat resistant to 100 C 212 F or more thickness o...

Страница 6: ...adhesive Observe the figure for piping work Use the included drain hose to change the extraction direction Max 65ft 5 to 7ft A B C B M L K D E D H I G D F F F Max 6inch J F Fig 5 1 Fig 5 2 1 Correct p...

Страница 7: ...uded with the manuals near each wiring diagram for the indoor and outdoor units 1 Max 50 m 165 ft 2 The 10 m 30 ft wire is attached in the remote controller accessory Max 500 m 1500 ft 3 The figures a...

Страница 8: ...troller accessory Max 500 m 1500 ft 3 The figures are NOT always against the ground Notes 1 Wiring size must comply with the applicable local and national code 2 Use copper supply wires 3 Use wires ra...

Страница 9: ...V DC12V DC12V DC12V DC12V DC12V DC12V Circuit rating Wiring Wire No size For heat pump models For heat pump models S1 S2 L1 L2 GR GR 1 2 L1 L2 S1 S2 S3 S3 A B C H D B E F S1 S2 L1 L2 GR GR 1 2 L1 L2 S...

Страница 10: ...ntrollers are connected set one to Main and the other to Sub For setting procedures refer to Function selection of remote controller in the operation manual for the indoor unit 6 2 2 For wireless remo...

Страница 11: ...1 to 04 7 Press the G button and the current set setting number 2 will flash Use the F button to switch the setting number in response to the power supply voltage to be used Power supply voltage 230...

Страница 12: ...on the power at least 12 hours before the test run 2 Press the TEST button twice TEST RUN liquid crystal display 3 Press the Mode selection button Make sure that wind is blown out 4 Press the Mode sel...

Страница 13: ...1 P1 Intake sensor error 2 P2 P9 Pipe Liquid or 2 phase pipe sensor error 3 E6 E7 Indoor outdoor unit communication error 4 P4 Drain sensor error 5 P5 Drain pump error 6 P6 Freezing Overheating safegu...

Страница 14: ...or voltage shortage and abnormal synchronous signal to main circuit Current sensor error 12 13 14 Others Other errors Refer to the technical manual for the outdoor unit 1 If the beeper does not sound...

Страница 15: ...d remote controller 1 for PLP 42AAMD 9 Installing the grille 1 4 5 6 2 0 2 3 Fig 9 1 Fig 9 2 A D C B A 11 16 3 16 0 Fig 9 3 B A C 1 1 D E 2 F G F B 1 9 2 Preparing to attach the grille Fig 9 2 With th...

Страница 16: ...the connector is not covered with the glass tube tracking resulting in fire may occur 9 Installing the grille C B A D B A D Fig 9 9 A Button B Vane motor C Up down vanes D Connector A Clamp B Cable C...

Страница 17: ...on procedures while waiting for the stable operation 10 Easy maintenance function This function only for A control By using the maintenance mode you can display many types of maintenance data on the r...

Страница 18: ...on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CH...

Отзывы: