Chapter 6 Wiring
6–4
6-2 Connector
CAUTION
Never connect the power wire to the signal terminal or the signal wire to the
power terminal. There is a risk of electric shock. Failure to observe this can
also cause damage or faults with the NC unit or devices connected to the NC.
DANGER
Apply only the designated voltage to each terminal. Failure to observe this
could lead to damage or faults.
6-2-1 Connector signal layout
(1) HS-RFxxE, HS-SFxxE
A
TXD
B
RXD
C
EMG
D
ALM
F
RXD
*
G
EMG
*
H
ALM
*
I
BAT
E
TXD
*
K
L2
J
L1
L
L3
M
PE
R
RG
S
Open
T
GND
N
L11
U
L12
W
BR
X
MON
V
Open
P
Open
(Japan Aviation)
Applicable connector: JL04V-28A28-11PE
(2) HS-MF23E
B1
L2
B2
PE
B3
L12
A1
L1
A2
Open
A3
L11
A1
TXD
A2
RXD
A3
EMG
B4
ALM
*
B6
GND
B6
FG
A4
ALM
A5
BAT
A6
MON
B4
EMG
*
B4
RXD
*
B1
TXD
*
Applicable connector:
Power connector : 178964-3 (AMP)
Signal connector : 178964-6 (AMP)