Chapter 6 Wiring
6–2
DANGER
1. Wiring work must be done by a qualified technician.
2. Wait at least 10 minutes after turning the power OFF and check the voltage
with a tester, etc., before starting wiring. Failure to observe this could lead
to electric shocks.
3. Securely ground the servo amplifier and servomotor with Class 3 grounding
or higher.
4. Wire the servo amplifier and servomotor after installation. Failure to
observe this could lead to electric shocks.
5. Do not damage, apply forcible stress, place heavy items or engage the
cable. Failure to observe this could lead to electric shocks.
CAUTION
1. Correctly and securely perform the wiring. Failure to do so could lead to
runaway of the servomotor.
2. Do not mistake the terminal connections.
Failure to observe this item could lead to ruptures or damage, etc.
3. Do not mistake the polarity ( + , – ). Failure to observe this item could lead
to ruptures or damage, etc.
4. Electronic devices used near the servo amplifier may receive magnetic
obstruction. Reduce the effect of magnetic obstacles by installing a noise
filter, etc.
5. Do not modify this unit.