ENGINE –
Water Pump and Water Hose
11-36
INSTALLATION SERVICE POINTS
"
A
A
WATER PIPE / O-RING INSTALLATION
Wet the O-ring (with water) to facilitate assembly.
Caution
Keep the O-ring free of oil or grease.
"
B
A
THERMOSTAT HOUSING INSTALLATION
Apply 3 mm diameter of form-in-place gasket (FIPG) to the
location shown in the illustration.
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equivalent
"
C
A
WATER OUTLET FITTING INSTALLATION
Apply 3 mm diameter of form-in-place gasket (FIPG) to the
location shown in the illustration.
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equivalent
"
D
A
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE GAUGE UNIT
(1) When reusing the gauge unit, clean its thread.
(2) Apply the specified sealant to the thread.
Specified sealant:
3M
TM
AAD Part No. 8672 or equivalent
"
E
A
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE SENSOR
(1) When reusing the sensor, clean its thread.
(2) Apply the specified sealant to the thread.
Specified sealant:
3M
TM
AAD Part No. 8731 or equivalent
6EN0594
Water pipe
O-ring
9EN0092
9EN0091