– Heater Control Assembly and A/C Switch
HEATER AND MANUAL
AIR CONDITIONER
55-17
5.
Follow the steps below to install the inside/outside air
changeover damper lever cable.
(1) Set the inside/outside air changeover damper link
on the blower unit to the INSIDE position.
(2) Set the inside/outside air changeover damper knob
of the heater control assembly to the INSIDE position.
(3) After inserting the inner cable into the link, pull the
outer cable to the heater control assembly side and
then fasten the outer cable to the clip of the blower
unit.
(4) After installation, ensure that inside/outside air
changeover damper operates smoothly by operating
the heater control assembly knob.
INSPECTION
A/C SWITCH CONTINUITY CHECK
Switch
iti
Terminal No.
position
1
ILL
2
IND
4
5
7
OFF
ON
BLOWER SWITCH CONTINUITY CHECK
Switch position
Terminal No.
1
2
3
5
6
7
8
OFF
D
(LO)
D
(ML)
D
(MH)
D
(HI)
INSIDE position
Push
OFF
ON