background image

17

Advanced Functions

Reference page

ENGLISH

Picture quality adjustment

This control allows you to adjust the playback picture so that the
outline is sharper or softer.

1. During playback, turn PICTURE control to the right or left.

Turning to the right makes the picture sharper.

Turning to the left makes the picture softer.

Vertical adjustment (picture vibration at the top and
bottom)

The picture vibration during still picture, fast playback or
playback at L18H-128H mode can be reduced or eliminated by
the following steps.

How to adjust

1. Press PAUSE button during playback.
2

Press  VERTICAL ADJUST button (+) or (–) to reduce or
eliminate the picture vibration.

Initialising the vertical adjustment

The vertical adjustment will be reset to its initial setting by
pressing both VERTICAL ADJUST buttons (+) and (–) together
during still picture or playback at L18H-128H mode.

Note

Horizontal vibration cannot be corrected with VERTICAL
ADJUST 
buttons.

VERTICAL ADJUST buttons will not work when QUASI V-
SYNC of FIRST TIME SET UP menu is set to OFF.

The picture vibration during still picture, frame or field playback
may not be adjusted with the VERTICAL ADJUST buttons.

SOFT

SHARP

Searching Techniques

The various search functions help you to find pictures you wish
to view.

Counter memory stop

Rewinds a tape until the counter on the fluorescent display
reaches “00000” and stops.

1. Press SEARCH button once.

<SEARCH FUNCTION> menu
appears and COUNTER
MEMORY STOP
 is highlighted.

The Counter Memory Stop indicator
( ) illuminates on the fluorescent
display.

2. Turn SHUTTLE to the right.

The VCR starts rewinding the tape.
To quit while rewinding, press STOP button.
To exit the <SEARCH FUNCTION> menu without
rewinding, press STOP button.

<SEARCH FUNCTION>

COUNTER MEMORY STOP

SKIP SEARCH

INDEX SEARCH

TIME DATE SEARCH

Turn the SHUTTLE RING

     or      to execute.

Press STOP to exit.

Note

When the counter on the fluorescent display indicates
“00000”, COUNTER MEMORY STOP on the SEARCH
FUNCTION menu cannot be selected.

Skip search

During fast forwarding or rewinding, the VCR plays back a tape
(at 3H, 4H, 6H or 8H mode) for about 4 seconds where an index
signal is recorded.  This process is repeated until the end or
beginning of the tape is reached.

1. Press SEARCH button until SKIP

SEARCH is highlighted.

The Skip Search indicator (

)

illuminates on the fluorescent
display.

2. Turn SHUTTLE to the right or left.

Turning to the right proceeds the search in the forward
direction.

Turning to the left proceeds the search in the reverse
direction.
To quit while searching, press STOP button.
To exit the <SEARCH FUNCTION> menu without
searching, press STOP button.

3. When you find a picture you wish to view, press PLAY

button.

Note

The index signal may be difficult to locate in some recording
conditions.

Audio output is muted during the skip search.

Info.

Skip search or index search may not function if the interval
between two alarm recording start-times is too short.  The
table below indicates the minimum interval between two
alarm recording start-times for the skip or index search to
work correctly.

Minimum interval

between two alarm

recording start-times

Alarm

recording

mode

3H(4H)
6H(8H)

L18H(L24H)
L30H(L40H)

approx. 15 sec.
approx. 15 sec.

approx. 2 min.
approx. 2 min.

(  ) appears when TAPE LENGTH is set to E-240.

ALARM
RECORDING

ALARM
RECORDING

Present position

Index

Fast forward

Fast forward

Index

Approx. 4 sec.
playback

Approx. 4 sec.
playback

Fast forward

<SEARCH FUNCTION>

COUNTER MEMORY STOP

SKIP SEARCH

INDEX SEARCH

TIME DATE SEARCH

Turn the SHUTTLE RING

to execute.

Press STOP to exit.

When the picture is vibrating

Содержание HS-1096E

Страница 1: ...RDER MODEL HS 1096E INSTALLATION AND OPERATION MANUAL Only video cassette tapes with the mark may be used with this model This instruction manual is important to you Please read it before using your v...

Страница 2: ...68 EEC The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas business light indu...

Страница 3: ...f the cabinet or inserting foreign objects of any kind not only creates a safety hazard but can also cause extensive damage PROTECT THE POWER CORD Damage to the power cord may cause fire or shock haza...

Страница 4: ...Recording 12 Series Recording 13 Remote Recording 13 Repeat Recording 13 Synchronous Recording 14 Additional Features 14 Memory Backup in Case of Power Failure 14 After a Power Failure 14 Displaying C...

Страница 5: ...AY MODE buttons Press to select the recording or playback speed TRACKING buttons Press to reduce eliminate the noise during playback slow playback etc POSITION VERTICAL ADJUST buttons When the day and...

Страница 6: ...cator Illuminates when TAPE END in FIRST TIME SET UP menu is set to REPEAT or ALARM PROT Cassette Status indicator Illuminates when a tape is inserted The light advances stops or flashes corresponding...

Страница 7: ...ERMINAL menu is set to CLOCK ADJ the clock of all connected VCR s can be adjusted page 21 CLK OUT Use to control an external camera switcher CALL OUT Use to indicate when a tape reaches its end during...

Страница 8: ...R has a protection circuit which will eject the tape if it is loaded improperly If the VCR ejects the tape remove it completely and check that the long narrow edge with the contents label is facing to...

Страница 9: ...ear track Note Audio will not be recorded if peripherals for audio are not connected to the AUDIO IN connector The longer the recording mode is set the worse the sound quality gets In L30H or L40H mod...

Страница 10: ...minutes ahead of the reference time being used After the step 7 above when reference time reaches 00 second of the minute you have chosen turn SHUTTLE to the right The VCR s clock now corresponds to t...

Страница 11: ...RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 TUE 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 TUE 12 00 3 PROGRAM TO...

Страница 12: ...d during timer recording even if the timer recording end time reaches An alarm recording will be cancelled if the tape reaches its end If the interval between two alarm recording start times is too sh...

Страница 13: ...OUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END STOP QUASI V SYNC ON VIDEO MODE COLOUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END REWIND QUASI V SYNC ON VIDEO MODE...

Страница 14: ...EC 1 MODE OUT REC REC IN SERIES REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT T L REC F MODE OUT REC REC IN SERIES REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SYNC REC No...

Страница 15: ...ding start times will be displayed If more than 8 alarm recordings have occurred the first start time and the last 7 start times will be displayed on the list Clearing the alarm list 1 Select ALARM LI...

Страница 16: ...ck speed varies by the angle of SHUTTLE ring When SHUTTLE ring is released it comes back to the centre position and the playback picture stays at still Note If a tape recorded in LP mode is played bac...

Страница 17: ...rewinding press STOP button SEARCH FUNCTION COUNTER MEMORY STOP SKIP SEARCH INDEX SEARCH TIME DATE SEARCH Turn the SHUTTLE RING or to execute Press STOP to exit Note When the counter on the fluoresce...

Страница 18: ...the fluorescent display during search 2 Turn SHUTTLE to the right TIME DATE SEARCH menu appears 3 Turn JOG to set hour digits of TIME you wish to find and turn SHUTTLE to the right To exit the TIME D...

Страница 19: ...UT IN REMOTE IN RESET RST IN REC GND ALM ALM MODE CLK OUT CALL MIC VIDEO OUT AUDIO OUT AUDIO IN VIDEO IN AUDIO IN SENSOR CCTV CAMERA ALM IN GND VIDEO IN VIDEO OUT MONITOR MICROPHONE AMPLIFIER MICROPHO...

Страница 20: ...Recording Connection Connect VCRs to be used as shown below page 13 for the menu setting Remote Recording Connection Connect the VCR with a remote switch as shown below page 13 for the menu setting 1...

Страница 21: ...TH 01 DAY 31 YEAR 2001 TIME 00 00 00 TIME DATE ADJUST DAYLIGHT SAVINGS AUTO MONTH 07 DAY 09 YEAR 2002 TIME 20 25 00 Accurately set the day and present time before timer programming Day Month Year Hour...

Страница 22: ...3H ALARM REC DURATION 1M EMERGENCY REC OFF CLOG DETECT OFF REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SERIES MAINTENANCE POWER LOSS LIST ALARM LIST ALL MENU INITIALISE P...

Страница 23: ...AM Sets the timer recording RECORDING SET UP Sets the alarm recording mode alarm recording duration and emergency recording etc REAR TERMINAL Sets the frequency division ratio of CLOCK OUT output sign...

Страница 24: ...e clock pulse output When JOG is turned the display will be switched in the order of 1 2 3 4 5 10 15 20 25 30 50 60 F field 1 The numbers 1 to 60 indicate the number of frames at 3H 4H 6H or 8H record...

Страница 25: ...uasi V sync signal is not inserted Note Some multiplexers may require QUASI V SYNC to be OFF in order to work properly Setting the playback recording colour mode VIDEO MODE AUTO The VCR automatically...

Страница 26: ...connector MJ 3 Environmental temperature 5 40 C common with VCR 4 Relative temperature Max 80 common with VCR Remote control switch functions PLAY EJECT SP EP STOP REC PAUSE STILL FR ADV REV FR ADV F...

Страница 27: ...cted to the outlet for approximately 40 or more hours per week when using it everyday Make sure the power cord is connected to the outlet for approximately 40 or more hours per week when using it ever...

Страница 28: ...tons on the front panel Adjust the picture by pressing VERTICAL ADJUST buttons on the front panel The video heads may be clogged Clean the video heads by using the video head cleaning cassette availab...

Страница 29: ...lly remove any particles that may accumulate on the heads during time lapse recording mode If it cannot be entirely removed CLOg flashes on the fluorescent display If so follow the remedy of CLOg in t...

Страница 30: ...L OUT Interface circuit inside the VCR ALM RST REC IN terminals screw Active When input terminals are short circuited to GND or L level voltage 0 to 1 6 V applied Time for active 0 1 sec or over Non a...

Страница 31: ...e Ratio Better than 43 dB Frequency Response 70 Hz 7 kHz 3H mode General Power Source AC 100 230 V 10 50 60 Hz Power Consumption Approx 18 watts Television System CCIR standard 625 lines 50 field PAL...

Страница 32: ...872C270A9 PRINTED IN JAPAN...