background image

13

Advanced Functions

Reference page

ENGLISH

Series Recording 1

Series recording is possible if two or more of these units are
connected.  When the first VCR’s tape reaches its end or an
error occurs on VCR, the second VCR automatically begins
recording.

1. Press MENU button.

<MAIN MENU> appears.

2. Turn JOG to select REAR TERMINAL

and turn SHUTTLE to the right.

<REAR TERMINAL> menu
appears.

Step 3 and 4 on 1st VCR only:

3. When the cursor (

) is next to CALL

OUT, turn SHUTTLE to the right.

4. Turn JOG to select WRNG•TAPE

END and turn SHUTTLE to the right.

Step 5 and 6 on 2nd VCR only:

5. Turn JOG to select REC IN and turn

SHUTTLE to the right.

6. Turn JOG to select SERIES and turn

SHUTTLE to the right.

7. Press MENU button.

The day and present time display appears on screen.

Series Recording 2

Series Recording 2 provides a function: when the first VCR’s
tape reaches its end, the second VCR automatically begins
recording.  When the tape in second VCR finishes, the first VCR
starts recording again.  (The two VCRs keep recording one after
another.)  Setup both 1st and 2nd VCRs as in the steps below.

1. Repeat step 1 to 6 of 

Series Recording 1.

Steps 3 to 6 must be set to both 1st and 2nd VCRs.

2. Turn SHUTTLE to the left.

<MAIN MENU> appears.

3. Turn JOG to select CLOCK/FIRST

TIME SET UP and turn SHUTTLE to
the right.

<FIRST TIME SET UP> menu
appears.

4. Turn JOG to select TAPE END and

turn SHUTTLE to the right.

5. Turn JOG to select REWIND and turn

SHUTTLE to the right.

6. Press MENU button.

The day and present time display appears on screen.

  page 20 for series recording connection

Note

Timer or emergency recording function cannot be used with
series recording at the same time.

<MAIN MENU>

DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE

<REAR TERMINAL>

CALL OUT

WRNG

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<REAR TERMINAL>

CALL OUT

WRNG

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<REAR TERMINAL>

CALL OUT

WRNG•TAPE END

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<REAR TERMINAL>

CALL OUT

WRNG

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<REAR TERMINAL>

CALL OUT

WRNG

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

SERIES

<MAIN MENU>

DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL

MAINTENANCE
CLOCK/FIRST TIME SET UP

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

REWIND

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

Remote Recording

This function permits you to control the start/end of recording
from the remote place.  The VCR starts recording when the
REC IN terminal is grounded. (

 page 20 for remote recording

connection)

1. Display <REAR TERMINAL> menu.

2. Set REC IN to REC-START/STOP.

3. Press MENU button.

The day and present time display
appears on screen.

Note

An index signal will not be recorded during remote recording.

Series or timer recording function cannot be used with
remote recording at the same time.

Repeat Recording

With this function, when the tape reaches its end during
recording, the VCR rewinds the tape and starts recording again.

1. Press MENU button.

<MAIN MENU> appears.

2. Turn JOG to select CLOCK/FIRST

TIME SET UP and turn SHUTTLE to
the right.

<FIRST TIME SET UP> menu
appears.

3. Turn JOG to select TAPE END and

turn SHUTTLE to the right.

4. Turn JOG to select REPEAT or

ALARM•PROT and turn SHUTTLE to
the right.

Repeat indicator (

) illuminates

on the fluorescent display.
Refer to the table below for
REPEAT and ALARM•PROT.

5. Press MENU button.

The day and present time display appears on screen.

When the tape reaches its end during recording

The following functions are automatically engaged when the
tape ends during recording.

*

To repeat recording on the same tape again, eject the tape
once and reinsert.

<REAR TERMINAL>

CALL OUT

WRNG•TAPE END

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<MAIN MENU>

DISPLAY

TIMER PROGRAM

RECORDING SET UP

REAR TERMINAL

MAINTENANCE

CLOCK/FIRST TIME SET UP

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

BUZZER

WRNG

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

BUZZER

WRNG

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

REPEAT

QUASI V-SYNC

ON

VIDEO MODE

COLOUR

TAPE LENGTH

E-180

BUZZER

WRNG

TAPE END

setting

REPEAT

REWIND

ALARM•

PROT

STOP

The tape stops.

When there are alarm
recordings on tape

When there is NO alarm
recording on tape

The tape stops.(*)

The tape is rewound
automatically to the
beginning and then
recording is resumed.

The tape is rewound automatically to the
beginning (except in timer recording) and
then stops.

The tape is rewound automatically to the
beginning and then recording is resumed
(also recording over existing alarms).

Содержание HS-1096E

Страница 1: ...RDER MODEL HS 1096E INSTALLATION AND OPERATION MANUAL Only video cassette tapes with the mark may be used with this model This instruction manual is important to you Please read it before using your v...

Страница 2: ...68 EEC The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas business light indu...

Страница 3: ...f the cabinet or inserting foreign objects of any kind not only creates a safety hazard but can also cause extensive damage PROTECT THE POWER CORD Damage to the power cord may cause fire or shock haza...

Страница 4: ...Recording 12 Series Recording 13 Remote Recording 13 Repeat Recording 13 Synchronous Recording 14 Additional Features 14 Memory Backup in Case of Power Failure 14 After a Power Failure 14 Displaying C...

Страница 5: ...AY MODE buttons Press to select the recording or playback speed TRACKING buttons Press to reduce eliminate the noise during playback slow playback etc POSITION VERTICAL ADJUST buttons When the day and...

Страница 6: ...cator Illuminates when TAPE END in FIRST TIME SET UP menu is set to REPEAT or ALARM PROT Cassette Status indicator Illuminates when a tape is inserted The light advances stops or flashes corresponding...

Страница 7: ...ERMINAL menu is set to CLOCK ADJ the clock of all connected VCR s can be adjusted page 21 CLK OUT Use to control an external camera switcher CALL OUT Use to indicate when a tape reaches its end during...

Страница 8: ...R has a protection circuit which will eject the tape if it is loaded improperly If the VCR ejects the tape remove it completely and check that the long narrow edge with the contents label is facing to...

Страница 9: ...ear track Note Audio will not be recorded if peripherals for audio are not connected to the AUDIO IN connector The longer the recording mode is set the worse the sound quality gets In L30H or L40H mod...

Страница 10: ...minutes ahead of the reference time being used After the step 7 above when reference time reaches 00 second of the minute you have chosen turn SHUTTLE to the right The VCR s clock now corresponds to t...

Страница 11: ...RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 TUE 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L30LP 2 TUE 12 00 3 PROGRAM TO...

Страница 12: ...d during timer recording even if the timer recording end time reaches An alarm recording will be cancelled if the tape reaches its end If the interval between two alarm recording start times is too sh...

Страница 13: ...OUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END STOP QUASI V SYNC ON VIDEO MODE COLOUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END REWIND QUASI V SYNC ON VIDEO MODE...

Страница 14: ...EC 1 MODE OUT REC REC IN SERIES REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT T L REC F MODE OUT REC REC IN SERIES REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SYNC REC No...

Страница 15: ...ding start times will be displayed If more than 8 alarm recordings have occurred the first start time and the last 7 start times will be displayed on the list Clearing the alarm list 1 Select ALARM LI...

Страница 16: ...ck speed varies by the angle of SHUTTLE ring When SHUTTLE ring is released it comes back to the centre position and the playback picture stays at still Note If a tape recorded in LP mode is played bac...

Страница 17: ...rewinding press STOP button SEARCH FUNCTION COUNTER MEMORY STOP SKIP SEARCH INDEX SEARCH TIME DATE SEARCH Turn the SHUTTLE RING or to execute Press STOP to exit Note When the counter on the fluoresce...

Страница 18: ...the fluorescent display during search 2 Turn SHUTTLE to the right TIME DATE SEARCH menu appears 3 Turn JOG to set hour digits of TIME you wish to find and turn SHUTTLE to the right To exit the TIME D...

Страница 19: ...UT IN REMOTE IN RESET RST IN REC GND ALM ALM MODE CLK OUT CALL MIC VIDEO OUT AUDIO OUT AUDIO IN VIDEO IN AUDIO IN SENSOR CCTV CAMERA ALM IN GND VIDEO IN VIDEO OUT MONITOR MICROPHONE AMPLIFIER MICROPHO...

Страница 20: ...Recording Connection Connect VCRs to be used as shown below page 13 for the menu setting Remote Recording Connection Connect the VCR with a remote switch as shown below page 13 for the menu setting 1...

Страница 21: ...TH 01 DAY 31 YEAR 2001 TIME 00 00 00 TIME DATE ADJUST DAYLIGHT SAVINGS AUTO MONTH 07 DAY 09 YEAR 2002 TIME 20 25 00 Accurately set the day and present time before timer programming Day Month Year Hour...

Страница 22: ...3H ALARM REC DURATION 1M EMERGENCY REC OFF CLOG DETECT OFF REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SERIES MAINTENANCE POWER LOSS LIST ALARM LIST ALL MENU INITIALISE P...

Страница 23: ...AM Sets the timer recording RECORDING SET UP Sets the alarm recording mode alarm recording duration and emergency recording etc REAR TERMINAL Sets the frequency division ratio of CLOCK OUT output sign...

Страница 24: ...e clock pulse output When JOG is turned the display will be switched in the order of 1 2 3 4 5 10 15 20 25 30 50 60 F field 1 The numbers 1 to 60 indicate the number of frames at 3H 4H 6H or 8H record...

Страница 25: ...uasi V sync signal is not inserted Note Some multiplexers may require QUASI V SYNC to be OFF in order to work properly Setting the playback recording colour mode VIDEO MODE AUTO The VCR automatically...

Страница 26: ...connector MJ 3 Environmental temperature 5 40 C common with VCR 4 Relative temperature Max 80 common with VCR Remote control switch functions PLAY EJECT SP EP STOP REC PAUSE STILL FR ADV REV FR ADV F...

Страница 27: ...cted to the outlet for approximately 40 or more hours per week when using it everyday Make sure the power cord is connected to the outlet for approximately 40 or more hours per week when using it ever...

Страница 28: ...tons on the front panel Adjust the picture by pressing VERTICAL ADJUST buttons on the front panel The video heads may be clogged Clean the video heads by using the video head cleaning cassette availab...

Страница 29: ...lly remove any particles that may accumulate on the heads during time lapse recording mode If it cannot be entirely removed CLOg flashes on the fluorescent display If so follow the remedy of CLOg in t...

Страница 30: ...L OUT Interface circuit inside the VCR ALM RST REC IN terminals screw Active When input terminals are short circuited to GND or L level voltage 0 to 1 6 V applied Time for active 0 1 sec or over Non a...

Страница 31: ...e Ratio Better than 43 dB Frequency Response 70 Hz 7 kHz 3H mode General Power Source AC 100 230 V 10 50 60 Hz Power Consumption Approx 18 watts Television System CCIR standard 625 lines 50 field PAL...

Страница 32: ...872C270A9 PRINTED IN JAPAN...

Отзывы: