This manual only describes the specifications for Display Module FX
1N
-5DM.
For complete operation, wiring, mounting and programming instructions please refer to the FX
1S
, FX
1N
HARDWARE MANUAL and PROGRAMMING MANUAL.
These manuals should be read and understood before attempting to install or use the unit.
Related Manuals
1. Outline of Product
1.1 Features
The micro display module FX
1N
-5DM (hereafter referred to as "5DM") is
mounted on the top face of the FX
1S
/FX
1N
Series PLC basic unit and
can monitor/update internal PLC data.
PLCs installed to: FX
1S
and FX
1N
Series
1.2 Product configuration
Main unit
: FX
1N
-5DM
Accessories : Top cover for DM 1,
M3 screw to mount top cover 1
1.3 Outside dimensions
1.4 Name of each part
➀
ESC key: Cancels the last key operation or returns to the previous screen.
➁
"-" key: Scrolls the device No. to a smaller one or decrements a numeric
value by.
➂
"+" key: Scrolls the device No. to a larger one or increments a numeric
value.
➃
OK key: Determines the display device, executes write of a numeric value,
or changes over forced setting and forced resetting.
➄
Display area: Displays the current time and the monitored device status.
➅
Connector for PLC
➆
5DM mounting hook
Manual name
Manual No.
Description
FX
1S
Series Hardware
Manual
JY992D83901
Describes contents related to hardware of FX
1S
Series
PLC such as specifications, wiring and installation.
(It is offered with FX
1S
Series PLC basic unit.)
FX
1N
Series Hardware
Manual
JY992D88201
Describes contents related to hardware of FX
1N
Series
PLC such as specifications, wiring and installation.
(It is offered with FX
1N
Series PLC basic unit.)
FX Series
Programming Manual
II
JY992D88101
Describes instructions in FX
1S
/FX
1N
/FX
2N
/FX
2NC
Series.
X4
L
N
X0
X2
COM
X5
X1
X3
COM
Y3
Y0
Y2
Y1
COM2
COM1
24+
COM3
COM0
POWER
ERROR
FX
1S
-10MR
OUT
0 1 2 3
RUN
0 1 2 3
5
4
10MR
- 264V
AC85
OK
+
-
ESC
IN
FX
1N
-5DM
ESC
-
+
OK
40(1.57)
32(1.26)
11(0.43)
17(0.67)
36
(1.41)
32
(1.25)
22
(0.86)
28
(1.1)
14
(0.55)
7.5
(0.29)
2.6(0.1)
4.6
(0.18)
2
(0.07)
40
(1.57)
26
(1.03)
9
(0.35)
10
(0.39)
8
(0.31)
8
(0.31)
8
(0.31)
FX
1S
Series
FX
1N
Series
When installed to a PLC
Note: These dimensions
measured
from the left side
are common
to the FX
1S
and
FX
1N
Series.
Unit: mm (inches)
Outer painting color: Munsell 0.08GY/7.64/0.81
Mass: 20 g (0.05 lbs)
ESC
-
+
OK
➀ ➁ ➂ ➃
➄
➅
➆
2. Installation
Install the 5DM to the PLC using the following procedure.
A) Top cover for DM (offered as an accessory of 5DM)
B) Connector for optional equipment
C) M3 screw to fix top cover
•
Remove the top cover of the basic unit, and attach the top cover for DM
A) instead.
Plug the 5DM in to the connector B).
•
If the 5DM is always used, the top cover can be fixed with the M3 screw
C). (Tightening torque: 0.3 to 0.6 N
x
m)
If the 5DM is used together with a function expansion board, remove and
attach the 5DM by pressing the 5DM mounting hook provided at the bottom
of the 5DM.
3. Specifications
3.1 Environmental specifications
The environmental specifications are equivalent to those of the PLC main unit. (Refer to the handy manual
offered with the FX
1S
/FX
1N
Series PLC main unit.)
3.2 Power supply specifications
The power is supplied from the PLC main unit.
5V DC, 110 mA
4. Outline of Performance
This section describes the function list of the 5DM.
The operator functions available with the operation keys of the 5DM are described on the back of this manual.
For the 5DM control functions available from the PLC, refer to the FX
1S
/FX
1N
/FX
2N
/FX
2NC
Series Program-
ming Manual.
4.1 Function list
Symbols stand for the following.
X: Input Y: Output M: Auxiliary relay S: State T: Timer C: Counter D: Data register
BFM: Butter memory of special units and special blocks
Operator functions: The operator can use these functions by using only the operation keys of the 5DM.
Refer to the simplified chart of operations shown on the back face of this manual.
5DM control functions: The 5DM is controlled by sequence programs.
For use of these functions, refer to the FX Series Programming Manual
ΙΙ
Function
Description
Clock function
Display
Displays current time of clock function (built in FX
1S
/FX
1N
Series).
Setting
Allows to set time (year, month, day, hour and minute).
Device monitor function
Bit device monitor
Displays ON/OFF status of X, Y, M and S.
Word device (16-bit) monitor
Displays current and set values of T and C and current value of D.
Word device (32-bit) monitor
Displays current and set values of 32-bit C and current value of D.
Buffer memory monitor function
Displays buffer memory of special units and special blocks
(offered only in FX
1N
Series).
Error display function
Displays error code and error occurrence step No. when a PLC
error has occurred.
Forced set/reset function
Forces ON and OFF bit devices Y, M and S.
T/C reset function
Clears current value of T and C (current value: 0, contact: OFF).
Data change function
Current value change
Change current value of T, C and D.
Set value change
Change set value of T and C.
Function
Description
Protect function
Enables full use of all operator functions, enables only monitor
function or enables only clock time display function.
Specified device monitor function
Allows to specify device type and device No. to be displayed in
5DM.
Error display enable/disable
function
Enables or disables error display function (operator function).
Automatic backlight OFF function
Allows to set automatic backlight OFF time (initial value: 10 min).
Operation key status recognition
function
Recognizes ON/OFF status of four operation keys.
B)
A)
C)
Cautions:
1) If a keyword to prohibit read, write or read and write of programs is registered in the PLC, only the
clock time display function is available. Any other function shown above is not available.
If any operation is performed in the 5DM when a keyword is registered in the PLC, the error display
flickers for 5 seconds.
2) The automatic backlight OFF function is set to 10 minutes as the initial value. As far as the OFF time
is not changed by a sequence program, the backlight turns off 10 minutes later.
If any key is pressed after the backlight turns off, the contents displayed just before the backlight turns
off appear again. A key pressed for the first time after the backlight turns off is regarded as a trigger to
turn on the backlight, and is not regarded as a key operation.
4.2 Control devices for 5DM
When using the 5DM control function, specify data registers (D) and auxiliary relays (M) used to control
the 5DM to special data registers D8158 and D8159.
Five data registers and 15 auxiliary relays are occupied for control of the 5DM.
For the control device use procedure, refer to the FX
1S
/FX
1N
/FX
2N
/FX
2NC
Series Programming Manual.
*1 Input numeric values correspond to the devices as follows.
1: Input (X) 2: Output (Y) 3: Auxiliary relay (M) 4: State (S) 5: Timer (T)
6: Counter (C), 16-bit (current value/set value) and 32-bit (set value)
7: Data register (D), 16-bit8: Data register (D), 32-bit 9: Time display
10: Counter (C), 16-bit (current value/set value) and 32-bit (current value)
*2 0: Enables all operations. 1: Enables only the time display function.
2: Enables only the monitor function.
*3 PC hardware errors, parameter errors, grammatical errors and circuit errors are unconditionally displayed.
While this bit is ON, I/O configuration errors, parallel link errors and operation errors are also displayed.
*4 Every operation key is the momentary type, and functions as follows:
While a key is pressed and held: ON
While key is not pressed: OFF
4.3 Description on display area
The display area of the 5DM shows the following.
➀
"RUN": Displayed while the PLC is running, and not displayed while
the PLC is stopped.
➁
"BFM": Displays the contents of the buffer memory when a special
block is connected (only in the FX
1N
Series).
➂
"ON/OFF": Displayed while T or C is ON in the word device monitor
function, and not displayed while T or C is OFF.
➃
"R" (reset): Displayed while T or C is reset.
➄
"D" (32-bit): Displayed when a 32-bit D is specified.
➅
Device type: Displays the device type (T, C, D, X, Y, M or S) currently
being displayed.
➆
Device No.: Displays the device No. currently being displayed.
➇
Current value: Displays the current value of T, C or D.
➈
Set value: Displays the set value of T or C.
* In the case of 32-bit C or D, upper 5 digits are displayed in
➇
and the
lower 5 digits are displayed in
➈
.
Special D
Control device
Description
Application
D8158
K
{
D
{
Device type to be displayed *1
For specified device
monitor function
D
{
+1
Device No. to be displayed
D
{
+2
Backlight OFF time (min)
For automatic backlight
OFF function
D
{
+3
Protects display screen. *2
For protect function
D
{
+4
Not available.
D8159
K
M
Requests edition of displayed device data.
For specified device
monitor function
M
+1
Edition completion response
M
+2
Disables backlight OFF function.
(Turns on backlight forcedly.)
For automatic backlight
OFF function
M
+3
Displays or hides operation errors, etc. *3
Others
M
+4
ESC key status *4
For specified device
monitor function
M
+5
"-" key status *4
M
+6
"+" key status *4
M
+7
OK key status *4
M
+8
Not available.
M
+9
Not available.
M
+10
Not available.
M
+11
Not available.
M
+12
Not available.
M
+13
Not available.
M
+14
Not available.
RUN BFM
ON R D
TCD
-
XYMS
➀ ➁
➂ ➃ ➄
➇
➈
➅
➆