Parameter settings for a motor with encoder
59
2
Parameter settings for the motor under vector control
• Values in
indicate initial values.
Offline auto tuning is required (Refer to the FR-A800 Instruction Manual (Detailed).)
Set this parameter according to the motor.
Use the thermal protector input provided with the motor.
• When using the inverter with the SF-V5RU (1500 r/min series), refer to the table below to set
Pr.83 Rated motor voltage
and
Pr.84 Rated motor frequency
.
• When using the inverter with the SF-V5RU1, SF-V5RU3, or SF-V5RU4, refer to the table below to set
Pr.83 Rated motor
voltage
and
Pr.84 Rated motor frequency
.
Motor name
Pr.9
Electronic
thermal O/L
relay
Pr.71
Applied
motor
Pr.80
Motor
capacity
Pr.81
Number
of motor
poles
Pr.359/
Pr.852
Encoder
rotation
direction
Pr.369/
Pr.851
Number of
encoder
pulses
Mitsubishi
standard motor
SF-JR
Rated motor
current
0
Motor capacity
Number of
motor poles
1
1024
SF-JR 4P 1.5 kW or
lower
Rated motor
current
20
Motor capacity
4
1
1024
SF-HR
Rated motor
current
40
Motor capacity
Number of
motor poles
1
1024
Others
Rated motor
current
Motor capacity
Number of
motor poles
Mitsubishi
constant-torque
motor
SF-JRCA 4P
Rated motor
current
1
Motor capacity
4
1
1024
SF-HRCA
Rated motor
current
50
Motor capacity
Number of
motor poles
1
1024
Others
Rated motor
current
1(13)
Motor capacity
Number of
motor poles
Vector control
dedicated motor
SF-V5RU
(1500 r/min series)
0
30
Motor capacity
4
1
2048
SF-V5RU
(except for
1500 r/min series)
0
1(13)
Motor capacity
4
1
2048
SF-THY
0
30(33)
Motor capacity
4
1
2048
Other
manufacturer's
standard motor
―
Rated motor
current
Motor capacity
Number of
motor poles
Other
manufacturer's
constant-torque
motor
―
Rated motor
current
1(13)
Motor capacity
Number of
motor poles
PM motor
Refer to the instruction manual of the FR-A8APR.
Motor
capacity
SF-V5RU
Motor
capacity
SF-V5RU
Pr.83 (V)
Pr.84 (Hz)
Pr.83 (V)
Pr.84 (Hz)
1.5 kW
345
52
18.5 kW
346
51
2.2 kW
360
52
22 kW
336
51
3.7 kW
363
52
30 kW
328
51
5.5 kW
322
51
37 kW
332
51
7.5 kW
331
51
45 kW
342
51
11 kW
320
51
55 kW
317
51
15 kW
330
51
Motor model
Pr.83 setting
Pr.84 setting
SF-V5RU1-30kW or lower
320 V
33.33 Hz
SF-V5RU1-37kW
340 V
SF-V5RU3-22kW or lower
320 V
SF-V5RU3-30kW
340 V
SF-V5RU4-3.7kW and 7.5kW
300 V
16.67 Hz
SF-V5RU4 and motors other than
described above
320 V
Содержание FR-A846-00023