![Mitsubishi FR-A846-00023 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/mitsubishi/fr-a846-00023/fr-a846-00023_instruction-manual_1809256022.webp)
Terminal connection diagrams
21
2
2.4
Terminal connection diagrams
FM type
Three-phase
AC power
supply
MCCB
R/L1
S/L2
T/L3
PC
24VDC power supply
(Common for external power supply transistor)
Forward rotation start
Reverse rotation start
Start self-holding selection
Middle speed
High speed
Low speed
Jog operation
Second function selection
Output stop
Reset
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous
power failure
Frequency setting signals (Analog)
10E(+10V)
10(+5V)
2
(Analog common)
2
3
1
Auxiliary
input
Terminal 4 input
(Current input)
1
4
Frequency setting
potentiometer
1/2W1kΩ
∗4
Running
Up to frequency
Instantaneous
power failure
Overload
Frequency detection
Open collector output common
Sink/source
common
F/C
(FM)
SD
Control input signals
(No voltage input allowed)
∗1
Motor
Relay output 1
(Fault output)
C1
B1
A1
U
V
W
P1
Indicator
(Frequency meter, etc.)
+
-
(-)
(+)
Analog signal output
(0 to ±10VDC)
Earth
(Ground)
AM
5
DC0 to ±5V selectable
DC0 to ±10V
Multi-speed
selection
Open collector output
∗6
Moving-coil type
1mA full-scale
Contact input common
Calibration
resistor
∗8
Main circuit terminal
Control circuit terminal
DC0 to 5V
DC0 to 10V selectable
MC
Main circuit
C2
B2
A2
Relay output 2
Relay output
∗5
M
DC0 to 20mA
DC0 to 5V
DC0 to 10V
selectable
DC4 to 20mA
TXD+
Terminating
resistor
TXD-
RXD+
RXD-
GND
(SG)
Data
transmission
GND
RS-485 terminals
PU
connector
USB A
connector
USB
mini B
connector
SINK
SOURCE
∗2
∗3
∗3
∗7
∗3
∗3
Connector for plug-in option connection
STF
STR
STP(STOP)
RH
RM
RL
JOG
RT
MRS
RES
AU
CS
SD
RUN
SU
IPF
OL
FU
SE
Data
reception
(+)
(-)
5
EMC filter
ON/OFF
connecter
ON
OFF
+24
24V external power
supply input
SD
Common terminal
VCC
(+)
(-)
5V
(Permissible load current 100mA)
Sink logic
Earth (Ground)
connector 1 connector 2
connector 3
N/-
P/+
Control circuit
Initial value
Initial value
Initial value
ON
4
2
OFF
Voltage/current
input switch
Brake unit
(Option)
Safety monitor output
Safety monitor output common
So
SOC
S1
S2
PC
SD
SIC
Safety stop signal
Safety stop input (Channel 1)
Shorting
wire
Safety stop input common
Safety stop input (Channel 2)
Jumper
∗9
24V
Inrush current
limit circuit
24V
Output shutoff
circuit
Reactor