Common specifications
124
Available when a vector control compatible option is mounted.
Temperature applicable for a short time, e.g. in transit.
For the installation at an altitude above 1,000 m up to 2,500 m, derate the rated current 3% per 500 m.
This protective function is not available in the initial status.
In the initial setting for the the FR-A846-00170(5.5K) or higher, it is limited to 150% by the torque limit level.
2.9 m/s
2
or less for the FR-A846-01800(55K) or higher.
Protective/
warning function
Protective
function
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or
stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed,
Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat,
Instantaneous power failure, Undervoltage, Input phase loss
, Stall prevention stop, Loss of synchronism detection
Brake transistor alarm detection, Output side earth (ground) fault overcurrent, Output short circuit, Output phase loss,
External thermal relay operation
, PTC thermistor operation
, Option fault, Communication option fault, Parameter
storage device fault, PU disconnection, Retry count excess
, Parameter storage device fault, CPU fault, Operation
panel power supply short circuit, 24 VDC power fault, Abnormal output current detection
, Inrush current limit circuit
fault, Communication fault (inverter), Analog input fault, USB communication fault, Safety circuit fault, Overspeed
occurrence
, Speed deviation excess detection
, Signal loss detection
, Brake
sequence fault
, Encoder phase fault
, 4 mA input fault
, Option fault,
Opposite rotation deceleration fault
, Internal circuit fault, User definition error by the PLC function, Abnormal internal
temperature, Magnetic pole position unknown
Warning
function
Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU
stop, Speed limit indication
, Safety stop, Maintenance signal output
, USB host error, Home position return setting
error
, Home position return uncompleted
, Home position return parameter setting error
, Operation panel lock
Password locked
, Parameter write error, Copy operation error, Internal-circulation fan alarm, Continuous operation
during communication fault
Env
ir
o
n
m
ent
Ambient temperature
-10°C to +40°C (non-freezing)
Surrounding air humidity
95% RH or less (non-condensing),
Storage temperature
-20°C to +65°C
Atmosphere
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude/vibration
Maximum 1000 m above sea level
, 5.9 m/s
2
or less at 10 to 55 Hz (directions of X, Y, Z axes)