Installation of Installation boa
rd
Fixing on concr
ete wall
Use of nut anchor
Installation
boar
d
Bolt
(M6 12)
Standa
rd
hole
Fixing of indoor unit
Floor installation
W
all installation
Tapping sc
re
w
(860
)
10
3.5
156.5
72
6
585
5
585
595
(600)
30.
5
83.
5
(238)
CAUTION
• During the installation, do not lean on the control box or the display, as they may be damaged.
• Install the indoor unit on flat wall. If improperly installed, it may cause abnormal noise and vibration. (Distortion on the
wall shall be no larger than 3 mm.)
Secure using upper 2 screws for floor installations.
If possible, also attach two lower screws.
At first secure the installation board using 5
screws
and th
ei
ndoo
ru
ni
tu
sin
g2s
crews
.
Look for the inside wall structures (Intersediats
support or pillar and finally install the unit after
level surface has been checked.)
When practicing the half-console, make su
re
to fix the unit secur
ely.
Otherwise, it could fall.
Adjustment of the installation boa
rd
in the
horizontal dir
ection is to be conducted with five
scr
ews in a temporary tightened state.
Adjust so the boa
rd
will be level by tur
ning the
boar
d with the standa
rd
hole as the center
.
If ther
e is an obstacle such as a
cable cove
r, cut of
f the hatched
part befor
e installation.
Refrigerant pipe
Slit
Refrigerant pipe
Slit
Tape
Refrigerant pipe
155
45
105
130
140
CONNECTION OF REFRIGERANT PIPINGS
Pr
eparation
Indoor
(Do not tur
n)
Pr
ess
Remove
90
±
0.5˚
Dimension A (mm)
Liquid side ø6.35 : 9.1
Gas side
ø9.52 : 13.2
ø12.7 : 16.6
Measur
ement
B
Flaring block
Copper pipe
Connection
Finishing work and fixing
Insulation of the connection portion
Indoor
Liquid side
Gas side
(Do not tu
rn
)
Connection wiring, Earth wiring
Outer tape
Refrigerant piping
Drain hose
W
ood scr
ew
Clamp
Install the removed flared nuts to the pipes to
be connected, then flared the pipes.
Remove the flared nuts. (on both liquid and
gas sides)
CAUTION
Do not apply refrigerating machine oil to the flared surface.
CAUTION
• Flaring work
Copper pipe
diameter
Clutch type flare
tool for R410A
Conventional (R22) flare tool
ø6.35
ø9.52
ø12.7
0.0 - 0.5
0.0 - 0.5
0.0 - 0.5
1.0 - 1.5
1.0 - 1.5
1.0 - 1.5
1.5 - 2.0
1.5 - 2.0
2.0 - 2.5
Measurement B (mm)
Clutch type
Wing nut type
Use a flare tool designed for R410A or a conventional flare tool. Please note that measurement B (protrusion from the flaring block) will vary depending on the type of a flare tool in use. If a conventional flare tool is used, please use a copper pipe gauge or a similar instrument to check protrusion so that you can keep measurement B to a correct value.
Keep the openings of the pipes cover
ed with tapes etc.
to pr
event dust, sand, etc. fr
om entering them.
Connect the pipes on both liquid and gas sides.
Tighten the nuts to the following tor
que.
Liquid side (ø6.35) : 14.0 - 18.0 N·m (1.4 - 1.8 kgf·m)
Gas side (ø9.52)
: 34.0 - 42.0 N·m (3.4 - 4.2 kgf·m)
(ø12.7)
: 49.0 - 61.0 N·m (4.9 - 6.1 kgf·m)
CAUTION
Do not apply excess tor
que to the flar
ed nuts.
Otherwise, the flar
ed nuts may check depending.
CAUTION
Be car
eful not to str
ess the connecting
re
frigerant
pipes. (Do not pull with a for
ce of larger than 5 kgf.)
Cover the exterior portion with
outer tape and shape the piping
so it will match the contours of
the route that the piping to take.
Also fix the wiring and pipings to
the wall with clamps.
ELECTRICAL WIRING WORK
Pr
eparation of indoor unit
Terminal block
Sensor
Fixing sc
re
w
Clamp
Wiring holder
Remove the fixing screw of clamp.
Connect the connecting wire securely to the terminal block.
1) Connect the connection wire securely to the terminal
block. If the wire is not affixed completely, contact will be
poor, and it is dangerous as the terminal block may heat
up and catch fire.
2) Take care not to confuse the terminal numbers for indoor
and outdoor connections.
Fix the connecting wire by wiring clamp.
Pass the connecting wire through the wiring holder.
1
2
3
4
H05RNR4G1.5 (example) or 245IEC57
H
05
R
N
R
4 or
5
G
1.5
Harmonized cable type
300/500 volts
Natural-and/or synth, rubber wire insulation
Polychloroprene rubber conductors insulation
Stranded core
Number of conductors
One conductor of the cable is the earth conductor
(yellow/green)
Section of copper wire (mm
2
)
Mounting of connecting wires
In case of faulty wiring connection, the indoor unit stops, and then
the run lamp tur
ns on and the timer lamp blinks.
CAUTION
• During installation, do not lean on the control box or the
display, as they may be damaged.
• Pass the connecting wire securely through the wiring holder.
If it passeson the sensor, it may not detect suction
temperature and/or humidity.
• Earth wi
re
shall be Y
ellow/Gr
een (Y/G)
in color and longer than other AC wi
re
s
for safety r
eason.
• Cover the indoor unit’s flare-connected joints, after
they are checked for a gas leak, with an indoor unit
heat insulating material and then wrap them with a
tape with an attached pipe cover placed over the
heat insulating material’s slit area.
Use cables for interconnection wiring to avoid loosening of the wires.
CENELEC code for cables Required field cables.
Pass the r
efrigerant pipe
thr
ough the piping hole to
indoor side. Arrange the pipes accor
ding
to the dir
ection of piping.
Cover the coupling with insulator and then cover it with tapes
.
Use an attached pipe cover for heat insulation.
Position it so that the slit ar
ea faces upwa
rd
.
Add
band
10
Pipe cover
9
CAUTION
If heat insulation is insu
ff
icient, water leakage may
occu
r. In addition, the r
oom temperatu
re
sensor
may give a false alert due to heat radiation fr
om
the pipes.
• Forced cooling operatio
n
Turn on a power source again after a while after turn off a power source.
Then press continually the ON/OFF button 5 seconds or more.
Conventionally,
operate
the
wireless
remote
control
by
holding
in
your
hand.
Avoid
installing
it
on
a
clay
wall
etc.
INSTALLATION OF WIRELESS REMOTE CONTROL
Mounting method of battery
Fixing to pillar or wall
CAUTION
Do not use new and
old batteries together.
Wood screws
ø3.5 X 16
Wireless remote control
2
5
Cover
Battery
6
INSTALLATION TEST CHECK POINTS
After installation
Power source voltage is correct as the rating.
No gas leaks from the joints of the service valve.
Power cables and crossover wires are securely fixed to the terminal board.
The screw of the lid is tightened securely.
Test run
Air-conditioning operation is normal.
No abnormal noise.
Water drains smoothly.
Protective functions are not working
.
The wireless remote control is normal.
Operation of the unit has been explained to the customer. (Three-minutes restart preventive timer)
When the air-conditioner is restarted or when changing the operation, the unit will not start operating
for approximately 3 minutes. This is to protect the unit and it is not a malfunction.
Service valve is fully open.
The pipe joints for indoor and outdoor pipes have been insulated.
Check the following points again after completion of the installation, and before turning on the power. Conduct a test run aga
in and ensure that the unit operates properly.
At the same time, explain to the customer how to use the unit and how to take care of the unit following the user’s manual.
Connect charge hose to service port of outdoor unit
.
Liquid side : Close the service valve with hexagon wr
ench key
.
Gas side : Fully open the service valve
Carry out cooling operation. (If indoor temperatur
e is lo
w,
operate for
ced cooling operation.)
After low pr
essu
re
gauge become 0.01MPa, stop cooling
operation and close the service valve (gas side).
1
2
3
<How to pump down>
HOW TO RELOCATE OR DISPOSE OF THE UNIT
Unit ON/OFF button
In or
der to pr
otect the envi
ro
nment, be su
re
to pump down
(r
ecovery of
re
frigerant).
Pump down is the method of
re
covering
re
frigerant fr
om the
indoor unit to the outdoor unit when the pipes ar
er
emoved
fr
om the unit
.
Uncover
the
wireless
remote
control,
and
mount
the
batteries
[R03
(AAA,
Micro),
×
2
pieces]
in
the
body
regularly.
(Fit
the
poles
with
the
indication
marks,
+
&
−
without
fail)
CONCERNING TERMINAL
CONNECTION FOR AN INTERFACE
Remove the front panel and lid of control.
There is a terminal (respectively marked with CNS) for the indoor control
board.
In connecting an interface, connect to the respective terminal securely with
the connection harness supplied with an option
“Interface connection kit
SC-BIKN2-
E”
and fasten the connection harness onto the indoor control box
with the clamp supplied with the kit
.
For more details, please refer to the user’s manual of your “
Interface
connection kit SC-BIKN-
E”
.
1
2
Install the indoor unit according to the following instructions.
Secure the upper, right, and left spaces according to the
right figure.
Do not let the horizontal bar obstruct wind from blowing out
upward/downward or reception from the wirelee remote control.
The lattice size should be 70 % or greater of the open rate.
Cut the jumper cable (JP173) on the indoor circuit board to
control the blow-out angle.
1
2
3
4
Incorr
ect installation may cause pr
oblems such as non-cooling,
non-warming, and condensation water leaking into the r
oom.
CAUTION
Concealed installation
5cm or mo
re
5cm or mo
re
7cm
or
mo
re
2 - 3cm
JP171
JP170
JP172
JP173
COO
LO
NL
Y
AIR FLOW
SWITCH
CUS
TO
M
AU
TO
REST
AR
T
REMO
TE
/
Cu
t
Disconnect
When
two
air-conditioners
are
installed
in
the
same
room,
use
this
setting
when
the
two
air-
conditioners are not operated with one wireless remote control. Set the wireless remote control
INSTALLING TWO AIR-CONDITIONERS IN THE SAME ROOM
Setting the wireless remote control
Pull out the cover and take out batteries.
Disconnect the switching line next to the battery
with wire cutters.
Insert batteries. Close the cover.
1
2
3
Setting an indoor unit
1
2
Turn off the power source, and turn it on after 1 minute.
Point the wireless remote control that was set according to the
procedure described on the left side at the indoor unit and send
a signal by pressing the ACL switch on the wireless remote cont
rol.
Since the signal is sent in about 6 seconds after the ACL switch
is pressed, point the wireless remote control at the indoor unit for
some time.
3
Check that the reception buzzer sound “pip” is emitted from the
indoor unit.
At completion of the setting, the indoor unit emits a buzzer
sound “pip”. (If no reception tone is emitted, start the setting
from the beginning again.)
Fitting
Do remove the air filter.
Cover the body with the front panel.
Fit the 6 latches in the lower section,
then 3 latches in the upper section.
Tighten the 5 set screws.
Fit the air filter.
Fit the air inlet panel.
1
2
3
4
5
6
To
close, attach the panel after pulling
the strings, hold the panel at both ends
of upper part to lower downwa
rd
and
push it slightly until the latch works.
How to fit the fr
ont panel
Close and attachment of the air inler panel
Latch
Latch
1. Open the air inlet panel and remove
the air filters
.
2. Install the air-cleaning filter in the filter
holders, and then install the filter
holders in the air-conditioner
.
• Each air-cleaning filter can be
installed in the upper or lower filter
holder
.
3. Install the air filters and close the inlet
panel.
When installing an ai
r-
cleaning filter in the
indoor unit, be ca
re
fu
l
not to inju
re
your hand
with the heat exchange
r.
CAUTION
Air-cleaning filter
7
Filter holder
8
Installing the air
-cleaning filters
Reception
pip
TIM
E
SE
TU
P
AC
L
A
and indoor unit.
Содержание SRK60ZSX-S
Страница 52: ... 51 17 SCM T 225 C 2 C 1 C 2 C 1 C 2 C 1 A B G E F D B A PFA004Z025 Model FDE50VG ...
Страница 107: ... 106 17 SCM T 225 source PJA012D783 ...
Страница 349: ... 348 17 SCM T 225 l l l l l l er l l K K 12 5 Superlink E board SC ADNA E ...
Страница 350: ... 349 17 SCM T 225 l l l l l l l l ...