– 31 –
Contact your dealer
■
Turn off the power switch immediately and inform your dealer in any of the following situations:
•
The fuse or switch blows continuously.
•
The cable becomes extremely hot.
The covering of the cable is cracked.
•
The TV, radio or other equipment starts to malfunction.
•
A switch does not activate properly.
•
A strange noise is heard during operation.
•
When abnormalities occur, turn off the power source immediately and turn it on after 3 minutes. Restart the operation with ON/OFF
button of the remote control and the abnormalities still continue.
•
The RUN and TIMER lights on the unit display section blink quickly (0.5 seconds ON; 0.5 seconds OFF) or the lights do not work.
Auto restart function
■
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then
automatically resumes operations after the power has been restored.
■
The following settings will be canceled:
1
Timer settings
2
HIGH POWER operations
•
Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs
to be switched off.
•
When power failure occurs, the timer setting is canceled. Once power is resumed, set the timer again.
NOTE
DRED
■
This air-conditioner complies with the DRED (Demand Response Enabling Devices) standard AS/NZS4755.3.1 and supports demand
response modes 1, 2 and 3 (DRM1, 2 and 3). Since the air-conditioner limits the electric power or energy by receiving the DRED input
signal, the sense of cooling operation may deteriorate over time. The outdoor unit of this air-conditioner is equipped with a terminal block
for DRED input and supports ELV (Extra-Low Voltage) complying with AS/NZS60335.1.
Under DRED mode, RUN light and TIMER light blink alternately as shown.
RUN light
ON
OFF
2 seconds
2 seconds
2 seconds
2 seconds
ON
OFF
TIMER light
Display in DRED mode
RLF012A104B_EN.indd 31
RLF012A104B_EN.indd 31
9/12/2017 16:08:43
9/12/2017 16:08:43