Contents

1. Safety precautions

Before installing the unit, make sure you read all the “Safety precautions”. 

-

tion to the system. 

circuit power S

sc

 

is greater than or equal to S

sc

 (*1) at the interface point 

connected only to a supply with a short-circuit power S

sc

 greater than or 

equal to S

sc

 (*1)”

  S

sc

 (*1)

Model

S

sc 

(MVA)

ZM200, M200

1.35

ZM250, M250

1.35

After installation work has been completed,  explain the “Safety Precautions,” use, 
and  maintenance  of  the  unit  to  the  customer  according  to  the  information  in  the 
Operation  Manual  and  perform  the  test  run to  ensure  normal  operation.  Both  the 
Installation  Manual and  Operation  Manual must  be  given  to  the user  for  keeping. 
These manuals must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

 Warning:

technician to install and repair the unit. If the unit is installed incorrectly, 
water leakage, electric shock, or fire may result.

•   For installation and relocation work, follow the instructions in the Installa-

cause damage or injuries. In addition, water leakage, electric shock, or fire 
may result.

-

rectly installed unit may fall down and cause damage or injuries.

cause damage or injuries.

•   Ventilate the room if refrigerant leaks during operation. If refrigerant comes 

electrical work may result in electric shock or fire.

to connect the refrigerant pipes. If the pipes are not connected correctly, the 

• 

unit, electric shock or fire may result.

any other refrigerant and do not allow air to remain in the lines.

   The use of any refrigerant other than that specified for the system will cause 

case, this could lead to a serious impediment to securing product safety.

installed, water leakage, electric shock, or fire may result.

-

age.

location. If the unit is installed incorrectly, water leakage, electric shock, 

 Warning:

death to the user.

 Caution:

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
Please, dispose of this equipment at your local community waste collection/recycling centre.
In the European Union there are separate collection systems for used electrical and electronic product.
Please, help us to conserve the environment we live in!

 Caution:

1. Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. Installation location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Installing the outdoor unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4. Installing the refrigerant piping  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5. Drainage piping work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6. Electrical work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

7. Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8. Special Functions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9. System control (Fig. 9-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

11. Serial number  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

This mark is for R32 refrigerant only. Refrigerant type is written on nameplate of outdoor unit.

Read the OPERATION MANUAL carefully before operation.

Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.

Further information is available in the OPERATION MANUAL, INSTALLATION MANUAL, and the like.

Содержание ZM200

Страница 1: ...English ...

Страница 2: ...en de fr nl es it el pt da sv tr ru uk bg pl cs sk hu sl ro et lv lt hr sr no ...

Страница 3: ...t electric shock or fire may result any other refrigerant and do not allow air to remain in the lines The use of any refrigerant other than that specified for the system will cause case this could lead to a serious impediment to securing product safety installed water leakage electric shock or fire may result age location If the unit is installed incorrectly water leakage electric shock Warning de...

Страница 4: ...g the screen display quality Caution the edge of other parts injuries for looseness cracks or other damage If such defects are left uncorrected the unit may fall down and cause damage or injuries leak out Caution pipes lightning rods or telephone grounding lines If the unit is not prop erly grounded electric shock may result may result Caution damage the internal parts Keep the main power switch t...

Страница 5: ...ntilation If a refrig ing appropriate ventilation Avoid locations exposed to direct sunlight or other sources of heat Select a location from which noise emitted by the unit will not inconvenience neighbors Select a location permitting easy wiring and pipe access to the power source and indoor unit mulate Note that water may drain from the unit during operation Select a level location that can bear...

Страница 6: ... Fig 2 9 Obstacles at front only Fig 2 10 When using an optional air outlet guide the clearance is 500 mm or more Obstacles at front and rear only Fig 2 11 When using an optional air outlet guide the clearance is 500 mm or more Obstacles at rear sides and above only Fig 2 12 Leave 50 mm for ZM200 250 M200 250 space or more between the units Obstacles at rear only Fig 2 13 Obstacles at rear and abo...

Страница 7: ...t from the bottom of the installation space to the bottom edge of the open area should be 0 125 m or less Open area should be 75 or more opening B Install in a space with a depression height of 0 125 m Amin Height from the bottom of 0 125 m or less 75 or more opening Height from the bottom of 0 125 m or less Width W 0 9 m or more Height from the bottom 0 125 m or less Height H 0 15 m or more M kg ...

Страница 8: ... model so read the installation manual for the particular unit M kg Amin m 1 0 4 1 5 6 2 0 8 2 5 10 3 0 12 3 5 14 4 0 16 4 5 20 5 0 24 5 5 29 6 0 35 6 5 41 7 0 47 7 5 54 8 0 62 8 5 69 9 0 78 9 5 87 Wall mounted h0 1 8 m Ceiling concealed Cassette Ceiling suspended h0 2 2 m h0 2 2 m h0 2 2 m Case 1 for wall mounted ceiling suspended cassette and concealed M kg Amin m 1 84 No requirements 1 84 6 2 0...

Страница 9: ... wires etc if necessary to install the unit Use self tapping screws ø5 15 mm or less and install on site Warning cause damage or injuries rectly installed unit may fall down and cause damage or injuries mm pipes to connect the refrigerant pipes Use refrigerant pipes with the thick pipes are clean and do not contain any harmful contaminants such as sul Warning any other refrigerant and do not allow...

Страница 10: ... Remove the service panel 4 screws and the cover panel front 2 screws and cover panel rear 4 screws Perform refrigerant piping connections for the indoor outdoor unit when the out door unit s stop valve is completely closed Vacuum purge air from the indoor unit and the connection piping After connecting the refrigerant pipes check the connected pipes and the indoor unit for gas leaks Refer to 4 4 ...

Страница 11: ...t exceed 30 m If the pipe length exceeds 30 m charge the unit with additional R32 refrigerant according to the permitted pipe lengths in the chart below When the unit is stopped charge the unit with the additional refrigerant through the liquid stop valve after the pipe extensions and indoor unit have been vacu umized When the unit is operating add refrigerant to the gas check valve using a safety...

Страница 12: ...gth Maximum pipe length ZM200 250 Liquid pipe mm O D ø9 52 ø12 7 ø15 88 Thickness t0 8 t0 8 t1 0 Gas pipe mm O D ø19 05 ø22 2 ø25 4 ø28 58 ø19 05 ø22 2 ø25 4 ø28 58 ø22 2 ø25 4 ø28 58 ø31 75 Thickness t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 0 t1 1 ZM200 20m 20m 50m 30m Standard size 100m 30m 100m 30m 20m 20m 50m 30m 100m 30m 100m 30m 50m 20m 50m 20m 50m 20m 50m 20m ZM250 20m 20m 50m 3...

Страница 13: ...ecessary use the drain socket or the drain pan option When this unit is used as a FREE COMPO MULTI unit install the refrigerant piping with the restrictions indicated in the drawing on the left In addition if the restrictions are going to be exceeded or if there are going to be combinations of indoor and outdoor units refer to installation instructions for the indoor unit for details about the ins...

Страница 14: ... 6 1 Indoor unit Outdoor unit Remote controller Main switch Breaker Earth For Power For Power L1 L2 L3 N S1 S2 S3 Terminal block Indoor Outdoor connection terminal block S1 S2 S3 Service panel Clamp Clamp the cables so that they do not contact the center of the service panel or the gas valve Earth terminal Note reinstall it Caution ...

Страница 15: ...ure 3 The 10 m wire is attached in the remote controller accessory S3 terminal has 24 VDC against S2 terminal However between S3 and S1 these terminals are NOT electrically insulated by the transformer or other device 5 In multi phase appliances the colour of the neutral conductor of the supply cord if any shall be blue S1 S2 S3 S1 S2 S3 A Control Outdoor Unit 3 poles isolator Power supply Isolato...

Страница 16: ...mulated in the compressor the compressor must be warmed up at least 12 hours to prevent breakdown 4 If the insulation resistance rises above 1 M the compressor is not faulty Caution The compressor will not operate unless the power supply phase connection is correct Starting operation immediately after turning on the main power switch can result in severe damage to internal parts Keep the power swi...

Страница 17: ...nt X Y Relay External input adapter PAC SC36NA E Outdoor unit control board Max 10 m Power supply for relay 0 100 of the normal consumption The demand function will be activated when a commercially available timer or the contact input of an ON OFF switch is added to the CNDM connector option on the control board of the outdoor unit Complete the circuit as shown when using the external input adapte...

Страница 18: ...400 Three 50 Dimensions W H D mm 1050 1338 330 40 Sound level 1 Cooling dB A 59 59 58 59 Heating 62 62 60 62 1 Measured under rated operation frequency Sequential number for each unit 00001 99999 Month of manufacture A 1 B 2 C 3 D 4 E 5 F 6 G 7 H 8 J 9 K 10 L 11 M 12 ...

Отзывы: