75
Check of current limiting resistor
K
Outdoor unit does not operate at all or stops immediately due to over current.
●
Check other electric parts in the main circuit together in the case of the defective current-limiting resistor.
Turn ON the power
supply and press
EMERGENCY
OPERATION switch of
the indoor unit.
Replace the power P.C.
board or the compressor.
Replace the power P.C.
board or the inverter P.C.
board.
Does the rush current
limiting relay (X64) work
properly? (Normally it
close 1 minutes after
outdoor unit power ON.)
Yes
No
No
No
Yes
Yes
Does the current-limiting resistor
(R64A or R64B) on the power P.C.
board short out? (Normal
resistance : 5
5% )
Replace the power P.C.board.
Replace the power P.C. board.
Does LED on the inverter
P.C. board light up?
Check of LEV (Expansion valve)
L
Heating/Cooling does not work sufficiently.
[SUZ-KA25/35VA(H).TH]
When the current-limiting resistor is open, the rush current limiting relay (X64) may not work properly.
(For wireless remote controller use model)
Replace the LEV.
Expansion valve operates in
full-opening direction.
Is LEV properly fixed to the
expansion valve?
OK
Do you hear the expansion
valve "click, click·······"?
Do you feel the expansion
valve vibrate on touching it ?
Does the resistance of LEV
have the characteristics?
(Refer to 12-4.)
Measure each voltage between connector pins
of CN724 on the inverter P.C. board.
1.Pin
(-) Pin
(+)
2.Pin
(-) Pin
(+)
3.Pin
(-) Pin
(+)
4.Pin
(-) Pin
(+)
Is there about 3~5V AC between each?
NOTE: Measure the voltage by an analog tester.
No
Yes
Yes
Yes
No
Replace the
expansion valve.
Yes
No
No
Properly fix the LEV to the
expansion valve.
Replace the
inverter P.C. board.
NOTE : After check of LEV, do the undermentioned
operations.
1. Turn OFF the power supply and
turn ON again.
2. Press the RESET button on the remote
controller.
1. Regardless of normal or abnormal, a short
beep is emitted once as the signal is received.
Turn ON the power supply.
<Preparation of the remote controller>
While pressing both OPERATION SELECT
button and TOO COOL button on the remote
controller at the same time, press RESET button.
First, release RESET button.
And release the other two buttons after all LCD
except the set temperature in operation display
section of the remote controller is displayed after
3
seconds.
Press OPERATE/STOP (ON/OFF) button of the remote
controller (the set temperature is displayed) with the
remote controller headed towards the indoor unit.
1
ON/OFF
RESET
TOO
WARM
TOO
COOL
MODE
AUTO
COOL
DRY
HEAT
FAN
VANE
SELECT
TIME
ON/OFF
TOO
WARM
TOO
COOL
h