7
4
SPECIFICATIONS
Service Ref.
Power supply
Phase
Single
Cycle
60 Hz
Voltage
208/230 V
MCA
A
28
MOCP
A
40
Breaker size
A
30
External finish
Munsell 3Y 7.8/1.1
Heat exchanger
Plate fin coil
Defrost method
Reverse cycle
Crankcase heater
kW
—
Compressor
Hermetic
Model
Motor output
kW
2.5
R.L.A.
20
L.R.A.
27.5
Starter type
Inverter
Fan
Fan(drive)
o
No.
Propeller fan
o
2
Fan motor output
kW
0.086 + 0.086
Fan motor
F.L.A.
0.40 + 0.40
Airflow
m
3
/min
100
CFM
3530
Sound level
Cooling
dB
52
Heating
dB
53
Protection devices
HP switch
LP switch
Discharge thermo
Dimension
W
mm
950
D
mm
330+30
H
mm
1350
W
in
37-12/32
D
in
13 + 1-3/16
H
in
53-5/32
Weight
kg
lb
Refrigerant
Charged
kg
5.5
R410A
lb
12
Control
Linear expansion valve
Oil
Model
Ether (FV50S)
Charged
L
1.4
oz
45
Refrigerant
Pipe size OD
mm
9.52
piping
Liquid
in
3/8
Pipe size OD
mm
15.88
Gas
in
5/8
Connection method Indoor
Flared
Connection method Outdoor
Flared
Height difference
m
Maximum 30
IU - OU
ft
Maximum 100
Piping length
m
Maximum 75
ft
Maximum 245
PUZ-HA30NHA5
PUZ-HA36NHA5
ANB33FJEMT
120
265
OCH607
Содержание PUZ-HA30NHA5
Страница 99: ...99 OCH607 ...