67
SW2 setting
1
ON
2 3 4 5 6
Display detail
Explanation for display
Unit
Capacity setting display
Displayed as an outdoor capacity code
Code
display
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Outdoor unit setting information
Indoor pipe temperature/Liquid (TH2(1))
Indoor 1
−38–190
Code
display
˚F
−38–190 (−39–88
:
)
(When the temperature is 0ºF or less, “–” and
temperature are displayed by turns.)
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Indoor room temperature (TH1)
46–102
HA30N
Capacity Code
14
20
HA36N
Setting details
• The tens digit (Total display for applied setting)
• The ones digit
H·P/
Cooling only
Single phase/3 phase
Display details
0: H·P 1: Cooling only
0:
Single phase
2:
3 phase
Setting details
Defrosting switch
Display details
0: Normal 1: For high humidity
(Example) When heat pump, 3 phase and defrosting
(normal) are set up, “20” is displayed.
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Indoor pipe temperature/Cond./Eva.
(TH5(1))
Indoor 1
−38–190
−38–190 (−39–88
:
)
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
˚F
−38–190 (−39–88
:
)
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
−38–190 (−39–88
:
)
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
˚F
˚F
˚F
46–102 (8–39
:
)
Indoor pipe temperature/Liquid (TH2(2))
Indoor 2
−38–190
Indoor pipe temperature/Cond./Eva.
(TH5(2))
Indoor 2
−38–190
1
ON
2 3 4 5 6
The number of connected indoor units
Unit
0–3
(The number of connected indoor units are dis-
played.)
OCH607
Содержание PUZ-HA30NHA5
Страница 99: ...99 OCH607 ...