17
GB
6. Electrical work
Fig. 6-4
Fig. 6-5
TB7
TB3
(51)
L
3
L
1
OC
TB7
(53)
OC
L
4
L
5
M1 M2 S M1 M2 S
S
M1 M2 S
TB3
M1 M2 S
M1 M2 S
M1 M2
TB3A
A-IC
(01)
A-IC
(02)
A-IC
(03)
A-IC
(04)
A-IC
MA-RC
MA-RC
MA-RC
MA-RC
WL-RC
WL-RC
WL-RC
WL-RC
(05)
A-IC
(06)
A-IC
(07)
A-IC
(08)
S1
S2
S3
TB3A
S1
S2
TB15
1
2
A
B
A
B
A
B
A
B
TB15
1
2
TB15
1
2
TB15
1
2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3B
S1
S2
S3
TB3C
S1
S2
S3
TB3D
S1
S2
S3
TB3E
S1
S2
S3
TB3A
S1
S2
S3
TB3B
S1
S2
S3
TB3C
S1
S2
S3
M1
M2
S
TB5
M1
M2
S
TB5
L
(01)
(06)
2
A
A
A
TB7
TB3
(51)
L
5
L
1
OC
TB7
(53)
OC
L
6
L
7
M1 M2 S M1 M2 S
S
M1 M2 S
TB3
M1 M2 S
M1 M2 S
M1 M2
TB3A
A-IC
(01)
A-IC
(02)
A-IC
(03)
A-IC
(04)
A-IC
MA-RC
MA-RC
MA-RC
MA-RC
WL-RC
WL-RC
WL-RC
WL-RC
(05)
A-IC
(06)
A-IC
(07)
A-IC
(08)
S1
S2
S3
TB3A
S1
S2
TB15
1
2
A
B
A
B
A
B
A
B
TB15
1
2
TB15
1
2
TB15
1
2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3A
S1
S2
S3
TB3B
S1
S2
S3
TB3C
S1
S2
S3
TB3D
S1
S2
S3
TB3E
S1
S2
S3
TB3A
S1
S2
S3
TB3B
S1
S2
S3
TB3C
S1
S2
S3
M1
M2
S
TB5
M1
M2
S
TB5
L
2
A
A
A
M-IC
(09)
M-IC
(10)
MA-RC
MA-RC
TB5
M1
M2
TB15
1
2
A
B
A
B
TB15
1
2
S
TB5
M1
M2
S
L
3
L
4
<Example of Transmission Cable Wiring: Mixing system>
<Example of Transmission Cable Wiring: Connecting with Branch box>
<Permissible length>
Longest length via outdoor units:
L
1
+ L
2
+ L
3
+ L
4
+ L
5
+ L
6
+ L
7
{
500 m (1640 ft.)
(1.25 mm
2
or more)
Longest transmission cable length:
L
1
+ L
2
+ L
3
+ L
4
, L
5
+ L
6
, L
7
{
200 m (656 ft.) (1.25 mm
2
or more)
Power
Supply
Unit
System
controller
Branch Box
Branch Box
Branch Box
Branch Box
<Permissible Lengths>
Max length via outdoor units (M-NET cable):
L
1
+ L
2
+ L
3
+ L
4
+ L
5
{
500 m (1.25 mm
2
or more)
Max transmission cable length (M-NET cable):
L
1
+ L
2
, L
3
+ L
4
, L
5
{
200 m (1.25 mm
2
or more)
(01)
(06)
■
M-NET Remote Controller
■
MA Remote Controller
A
B
C
E
M-IC
S
2
M
1
M
TB5
M-NET RC
(01)
M-IC
S
2
M
1
M
TB5
(03)
M-IC
S
2
M
1
M
TB5
(02)
M-IC
M1
M2 S
TB5
(04)
M-IC
S
2
M
1
M
TB5
(05)
M-IC
S
2
M
1
M
TB5
(07)
M-IC
S
2
M
1
M
TB5
(06)
L
1
(101)
M-NET RC
(105)
(104)
M-NET RC
(155)
L
3
L
4
L
5
A B
A B
A B
A B
A
B
C
E
D
M1
M2 S
TB7
M-IC
(51)
S
2
1
2
M
1
M
TB5
TB15
1 2
TB15
1 2
TB15
1 2
TB15
1 2
TB15
1 2
TB15
1 2
TB15
MA-RC
(01)
M-IC
S
2
M
1
M
TB5
(03)
M-IC
M1
M2 S
TB5
(02)
M-IC
M1
M2 S
TB5
(04)
M-IC
M1
M2 S
TB5
(05)
M-IC
M1
M2 S
TB5
(07)
M-IC
M1
M2 S
TB5
(06)
L
2
L
1
OC
M1
M2 S
TB7
(53)
OC
m
1
m
4
S
S
L
3
L
6
L
7
L
4
m
3
A B
A B
A B
M1M2
M1M2
m
1
m
1
m
2
m
2
A B
M1M2 S
TB3
M1M2 S
TB3
M-NET RC
MA-RC
MA-RC
MA-RC
m
3
R
2
R
3
R
1
R
4
D
M1
M2 S
TB7
(51)
L
2
OC
M1
M2 S
TB7
(53)
OC
S
S
L
6
L
7
M1M2
M1M2
M1M2 S
TB3
M1M2 S
TB3
Fig. 6-3
Fig. 6-2
A
: Group 1
B
: Group 2
C
: Group 3
D
: Shielded Wire
E
: Sub Remote Controller
( ): Address
A
: Shielded wire
( ) : Address example
A
: Shielded wire
( ) : Address example
Power
Supply
Unit
System
controller
Power Supply
Unit
System
controller
System
controller
Power Supply
Unit
RG79Y968H01.indb 17
12/28/2017 11:24:57 AM
Содержание PUMY-SP112
Страница 338: ...A4_white_tombo indd 1 2016 04 25 10 16 47 ...
Страница 339: ...A4_white_tombo indd 1 2016 04 25 10 16 47 ...
Страница 340: ...A4_white_tombo indd 1 2016 04 25 10 16 47 ...