11
OCH665B
6
OUTLINES AND DIMENSIONS
PUHZ-FRP71VHA2 PUHZ-FRP71VHA2R1
Unit: mm
Handle
for moving
Earth terminal
Left
•••
Power supply wiring
Reight
••
Indoor/Outdoor wiring
Terminal Connections
Service panel
Handle for moving
Terminal Connections
Cylinder/Hydrobox wiring
377
431
669
950
322
943
473
23
677
Power supply wiring hole
(2-
[
27Knock-Out)
Right trunking hole
(Knock-Out)
Right piping hole
(Knock-Out)
63
73
75
40
92
92
27
23
55
19
[
92
Rear trunking hole
(Knock-Out)
Rear piping hole
(Knock-Out)
65
92
27
55
23
73
[
92
Front piping hole
(Knock-Out)
Front trunking hole
(Knock-Out)
Power supply wiring hole
(2-
[
27Knock-Out)
Piping Knock-Out Hole Details
27
55
73
23
63
40
92
65
45
[
92
Example of Notes
•••
Refrigerant GAS pipe connection (FLARE)
[
15.88(5/8F)
*Connect to indoor unit.
•••
Refrigerant LIQUID pipe connection (FLARE)
[
9.52(3/8F)
*Connect to indoor unit.
•••
Refrigerant GAS pipe connection (FLARE)
[
15.88(5/8F)
*Connect to cylinder unit or hydrobox.
•••
Refrigerant LIQUID pipe connection (FLARE)
[
9.52(3/8F)
*Connect to cylinder unit or hydrobox.
This tap mark indicates the cylinder/hydro unit
connection side for the following parts.
•
Terminal bed for the connecting cables, S1/S2/S3.
•
Stop valves, gas and liquid for the refrigerant connection.
BK79F295H01
Over 100mm
Over 500mm
Over 10mm
Over 10mm
FREE
Service
space
10
Over
100
Over
500
Over
500
Over
<Foundation bolt height>
Less than
FOUNDA
TION
30
The diagram below shows a
basic example.
Explanation of particular details are
given in the installation manuals etc.
1 FREE SP
ACE (Around the unit)
2 SER
VICE SP
ACE
3 FOUNDA
TION BOL
TS
4 PIPING-WIRING DIRECTIONS
Piping and wiring connections
can be made from 4 directions:
FRONT
,Right,Rear and Below
.
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts and washers must be
purchased locally
.)
Dimensions of space needed
for service access are
shown in the below diagram.
Bottom piping hole
(Knock-Out)
Drain hole
(5-
[
33)
219
81
30
220
145
145
145
71
71
Installation Feet
2-U Shaped notched holes
(Foundation Bolt M10)
2-12×36 oval holes
(Foundation Bolt M10)
Rear Air
Intake
Side Air
Intake
Air Discharge
417
19
25
330
370
175
175
600
70
28
54
64
53
0
42
84
42
83
0
Side Air
Intake
Rear piping cover
Front piping cover
Rear Air
Intake
Air Intake
Handle
for moving
Handle for
moving
1
2
3
4
1
2
3
4
Содержание PUHZ-FRP71VHA2R1
Страница 12: ...12 OCH665B 7 WIRING DIAGRAM PUHZ FRP71VHA2 PUHZ FRP71VHA2R1 ...
Страница 89: ...89 OCH665B ...