< Dual-In-Line Package Intelligent Power Module >
Series Application note
Publication Date: September 2016
5
CHAPTER 2 : SPECIFICATIONS and CHARACTERISTICS
2.1 Specification of
It is representatively described as follows with PSS25MC1FT (25A/1200V,CIB type).
For the other products, please refer each data sheets in details.
2.1.1 Maximum ratings
Maximum ratings are described as following table 2-1-1. (T
j
= 25°C, unless otherwise noted)
Table 2-1-1 Maximum rating of PSS25MC1FT (25A/1200V,CIB type)
MAXIMUM RATINGS
(T
j
= 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
Condition
Ratings
Unit
V
CC
Supply voltage
Applied between P-NU,NV,NW
900
V
V
CC(surge)
Supply voltage (surge)
Applied between P-NU,NV,NW
1000
V
V
CES
Collector-emitter voltage
1200
V
±I
C
Each IGBT collector current
T
C
= 25°C
(Note 1)
25
A
±I
CP
Each IGBT collector current (peak)
T
C
= 25°C,
less than 1ms
50
A
T
j
Junction temperature
-30~+150
°C
BRAKE PART
Symbol
Parameter
Condition
Ratings
Unit
V
CC
Supply voltage
Applied between P-N(B)
900
V
V
CC(surge)
Supply voltage (surge)
Applied between P-N(B)
1000
V
V
CES
Collector-emitter voltage
1200
V
I
C
Each IGBT collector current
T
C
= 25°C
(Note 1)
15
A
I
CP
Each IGBT collector current (peak)
T
C
= 25°C,
less than 1ms
30
A
V
RRM
Repetitive peak reverse voltage
1200
V
I
F
Forward current
T
C
= 25°C
15
A
I
FP
Forward current (peak)
30
A
T
j
Junction temperature
-30~+150
°C
CONVERTER PART
Symbol
Parameter
Condition
Ratings
Unit
V
RRM
Repetitive peak reverse voltage
1600
V
Io
DC output current
3-phase full wave rectification
25
A
I
FSM
Surge forward current
Peak value of half cycle at 60Hz, Non-repetitive
315
A
I
2
t
I
2
t capability
Value for 1 cycle of surge current
416
A
2
s
T
j
Junction temperature
-30~+150
°C
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Ratings
Unit
V
D
Control supply voltage
Applied between
V
P1
-V
NC
, V
N1
-V
NC
20
V
V
DB
Control supply voltage
Applied between
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
20
V
V
IN
Input voltage
Applied between
U
P
,V
P
,W
P
,U
N
, V
N
, W
N
, AIN-V
NC
-0.5~V
D
+0.5
V
V
FO
Fault output supply voltage
Applied between
F
O
-V
NC
-0.5~V
D
+0.5
V
I
FO
Fault output current
Sink current at F
O
terminal
5
mA
V
SC
Current sensing input voltage
Applied between CIN-V
NC
-0.5~V
D
+0.5
V
Note1: Pulse width and period are limited due to junction temperature.
(1)
(2)
(3)
(4)
(5)
(5)