5
GB
D
F
SW
I
NL
E
P
TIMER SET
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON
OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
FILTER
CHECK TEST
TEMP.
3
2
E
C
A
1
6 8 7
4
B
A
Before starting operation
•
Start running after the “HO” display has disappeared. The “HO” display briefly
appears on the room temperature display (max. 3 minutes) when the power is
turned on and after a power failure. This does not indicate any failure of the air
conditioner.
•
During heating operation, even if the indoor unit is set to operation while the
outdoor unit is in defrosting operation, operation starts after the defrosting op-
eration of the outdoor unit has ended.
3.1. ON/OFF
Start an operation
1. Press the
B
B
B
B
B
[ON/OFF] button
Operation lamp
lights up and operation starts.
Stop an operation
1. Press the
B
B
B
B
B
[ON/OFF] button again
Operation lamp goes off and operation stops.
•
Once the buttons have been set, pressing of the [ON/OFF] button only can
repeat the same operation thereafter.
•
During operation, the operation lamp above the [ON/OFF] button lights up.
Caution:
Even if the operation button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of ap-
proximately 3 minutes.
3.2. Selecting operation
When selecting operation
1. Press the
3
3
3
3
3
[selecting operation] button
Consecutive press of the selecting operation button switches the operation
over to
E
“
”, “
”, (“
”), and (“
”). For the contents of operation, check
the display.
For cooling
Press the
3
3
3
3
3
[selecting operation] button and bring up the “
” display.
For fan
Press the
3
3
3
3
3
[selecting operation] button and bring up the “
” display.
•
The fan operation functions to circulate the air in the room.
•
The temperature of the room cannot be set by fan operation.
Caution:
Never expose your body directly to cool air for a long time. Excessive expo-
sure to cool air is bad for your health, and should therefore be avoided.
For heating
Press the
3
3
3
3
3
[selecting operation] button to bring up the “
” display.
Regarding displays during heating operation “DEFROST”
Displayed only during the defrosting operation.
“STAND BY”
Displayed from the start of heating operation until the moment warm air blows out.
Caution:
•
When the air conditioner is used together with burners, thoroughly ven-
tilate the area. Insufficient ventilation can result in accidents due to oxy-
gen deficiency.
•
Never place a burner at a place where it is exposed to the airflow from the
air conditioner.
Doing so can result in imperfect combustion of the burner.
The microcomputer functions in the following cases:
•
Air does not blow out when heating starts.
- To prevent any cool air from escaping.
Wait a moment until the airflow comes out naturally.
•
The air keeps flowing out, even when the operation has been stopped.
For Approximately 1 minute after the operation stops, the fan sometimes
stays on to eliminate excess heat generated by various parts of the unit
such as the electric heater.
•
Air supply during thermo off can be stopped from the remote controller
provided that the remote controller is located within the air-conditioned
room and that the suction air temperature detection spot is switched
from “unit” to “remote control.”
Remote controller-Button
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON
OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
FILTER
CHECK TEST
TEMP.
TIMER SET
1
2
3
4 5 6 8 7 9
0
C
A
B
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON
OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
TEMP.
A
B
C
D
E
F
H
I K L J
M
P
N
O
R
S
Q
T
U
G
Remote controller-Display
1
[Room temperature adjustment] Button
2
[Timer/continuous] Button
3
[Selecting operation] Button
4
[Time selection] Button
[Time-setting] Button
5
[Louver] Button
6
[Fan speed adjustment] Button
7
[Up/down airflow direction] Button
8
[Ventilation] Button
9
[Checking/built-in] Button
0
[Test run] Button
A
[Filter] Button
B
[ON/OFF] Button
C
Position of built-in room temperature
•
Never expose the remote controller to direct sunlight. Doing so can result in
the erroneous measurement of room temperature.
•
Never place any obstacle around the lower right-hand section of the remote
controller. Doing so can result in the erroneous measurement of room tem-
perature.
A
Current time/Timer
B
Centralized control
C
Timer ON
D
Abnormality occurs
E
Operation mode:
COOL,
AUTO,
FAN,
HEAT
F
Preparing for Heating mode
G
Defrost mode
H
Set temperature
I
Power ON
J
Louver
K
Not available function
L
Ventilation
M
Function setting mode
N
Test run mode
O
Error check mode
P
Filter sign
Q
Set effective for 1 hr.
R
Sensor position
S
Room temperature
T
Airflow
U
Fan speed