Before starting operation

Start running after the “HO” display has disappeared. The “HO” display briefly
appears on the room temperature display (max. 3 minutes) when the power is
turned on and after a power failure. This does not indicate any failure of the air
conditioner.

During heating operation, even if the indoor unit is set to operation while the
outdoor unit is in defrosting operation, operation starts after the defrosting op-
eration of the outdoor unit has ended.

3.1. ON/OFF

Start an operation

1. Press the 

B

B

B

B

B

 [ON/OFF] button

Operation lamp 

 lights up and operation starts.

Stop an operation

1. Press the 

B

B

B

B

B

 [ON/OFF] button again

Operation lamp goes off and operation stops.

Once the buttons have been set, pressing of the [ON/OFF] button only can
repeat the same operation thereafter.

During operation, the operation lamp above the [ON/OFF] button lights up.

Caution:

Even if the operation button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of ap-
proximately 3 minutes.

3.2. Selecting operation

When selecting operation

1. Press the 

3

3

3

3

3

 

[selecting operation] button

Consecutive press of the selecting operation button switches the operation
over to 

E

 “

”, “

”, (“

”), and (“

”). For the contents of operation, check

the display.

For cooling

Press the 

3

3

3

3

3

 [selecting operation] button and bring up the “

” display.

For fan

Press the 

3

3

3

3

3

 [selecting operation] button and bring up the “

” display.

The fan operation functions to circulate the air in the room.

The temperature of the room cannot be set by fan operation.

Caution:

Never expose your body directly to cool air for a long time. Excessive expo-
sure to cool air is bad for your health, and should therefore be avoided.

For heating

Press the 

3

3

3

3

3

 [selecting operation] button to bring up the “

” display.

Regarding displays during heating operation “DEFROST”

Displayed only during the defrosting operation.

“STAND BY”

Displayed from the start of heating operation until the moment warm air blows out.

Caution:

When the air conditioner is used together with burners, thoroughly ven-
tilate the area. Insufficient ventilation can result in accidents due to oxy-
gen deficiency.

Never place a burner at a place where it is exposed to the airflow from the
air conditioner.
Doing so can result in imperfect combustion of the burner.

The microcomputer functions in the following cases:

Air does not blow out when heating starts.

- To prevent any cool air from escaping.

Wait a moment until the airflow comes out naturally.

The air keeps flowing out, even when the operation has been stopped.
For Approximately 1 minute after the operation stops, the fan sometimes
stays on to eliminate excess heat generated by various parts of the unit
such as the electric heater.

Air supply during thermo off can be stopped from the remote controller
provided that the remote controller is located within the air-conditioned
room and that the suction air temperature detection spot is switched
from “unit” to “remote control.”

Remote controller-Button

PAR-20MAA

ON/OFF 

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY 
DEFROST

FILTER

CHECK TEST

TEMP.

TIMER SET

1

2

3

4 5 6 8 7 9

0

C

A

B

ON/OFF 

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY 
DEFROST

TEMP.

A

B

C

D

E

F

H

I K L J

M

P

N

O

R

S

Q

T

U

G

Remote controller-Display

1

[Room temperature adjustment] Button

2

[Timer/continuous] Button

3

[Selecting operation] Button

4

[Time selection] Button

[Time-setting] Button

5

[Louver] Button

6

[Fan speed adjustment] Button

7

[Up/down airflow direction] Button

8

[Ventilation] Button

9

[Checking/built-in] Button

0

[Test run] Button

A

[Filter] Button

B

[ON/OFF] Button

C

Position of built-in room temperature

Never expose the remote controller to direct sunlight. Doing so can result in
the erroneous measurement of room temperature.

Never place any obstacle around the lower right-hand section of the remote
controller. Doing so can result in the erroneous measurement of room tem-
perature.

A

Current time/Timer

B

Centralized control

C

Timer ON

D

Abnormality occurs

E

Operation mode: 

 COOL,

 AUTO, 

 FAN, 

 HEAT

F

Preparing for Heating mode

G

Defrost mode

H

Set temperature

I

Power ON

J

Louver

K

Not available function

L

Ventilation

M

Function setting mode

N

Test run mode

O

Error check mode

P

Filter sign

Q

Set effective for 1 hr.

R

Sensor position

S

Room temperature

T

Airflow

U

Fan speed

Содержание PRH-P10MYA

Страница 1: ...IONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig ...

Страница 2: ...f top flow A Return air B Supply air C Outdoor heat exchanger air inlet D Outdoor heat exchanger air outlet E Fresh air intake Fig 2 0 2 A Remote controller ON OFF TEMP A A D B C E E C D C C A E E B A PRH P8 10MYA PRH P16 20MYA B A B A D D C E E C C A D D C E E C C B B ...

Страница 3: ...ting the unit make sure you read all the Safety precautions s Safety precautions lists important points about safety Please be sure to follow them Symbols used in the text Warning Describes precautions that should be observed to avoid the risk of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Symbols used in the illustrations Indicat...

Страница 4: ...any repair serv ice Improper repair work can result in water leakage electric shock fire etc If the remote controller displays an error indication the air conditioner does not run or there is any abnormality stop operation and contact your dealer Leaving the unit as it is under such conditions can result in fire or failure If the power breaker is frequently activated get in touch with your dealer ...

Страница 5: ...nt warm air blows out Caution When the air conditioner is used together with burners thoroughly ven tilate the area Insufficient ventilation can result in accidents due to oxy gen deficiency Never place a burner at a place where it is exposed to the airflow from the air conditioner Doing so can result in imperfect combustion of the burner The microcomputer functions in the following cases Air does...

Страница 6: ...cted to a power stop of the air conditioner or a power failure 3 6 Timer setting If the timer is set the unit starts stops at the set time and the time mode is terminated When you wish to confirm the starting and ending time press the 4 time selection button while C is displayed Function of timer On timer Set the on timer for the time the working day begins in your company When the set start time ...

Страница 7: ...shock or fire 3 7 Others CENTRALLY CONTROLLED Displayed when control is executed by a separately sold centralized control unit etc STAND BY DEFROST Displayed from the start of heating operation until the moment warm air blows out CHECK This displays indication when some abnormality oc curs in the unit NOT AVAILABLE When a button is pressed for any function which the indoor unit cannot perform this...

Страница 8: ...bstacles adjacent to the air outlet If the air conditioner produces any abnormal sound consult with your dealer Maintenance and inspection If the air conditioner is used throughout several seasons the insides can get dirty reducing the performance Depending upon the conditions of usage foul odors can be generated and drainage can deteriorate due to dust and dirt etc The unit started even though th...

Страница 9: ...the product nameplate attached to the unit for the electrical specifications 2 Rating conditions cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB 24 C WB 3 Rating conditions heating Indoor 20 C DB Outdoor 7 C DB 6 C WB Operating range Units should be installed by licensed electric contractor accordingly to local code requirement Cooling Heating Maximum Minimum Maximum Minimum Indoor air intake tempe...

Страница 10: ...he contact address telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Страница 11: ......

Отзывы: