17
OCH715
17
9/32(7.2)
0
3-15/64(82.2)
5-45/64(144.7)
9-41/64(244.7)
5/8(16)
0
2-1/4(57.2)
4-7/32(107.2) 5-13/64(132.2) 6-3/16(157.2)
7-15/32(189.7)
9-1/16(230)
63/64(25)
10-25/32(274)
7/16(11)
2-3/4(69.7) 2-63/64(76)
10-1/8(257.2)
1-49/64(44.7)
4-23/32(119.7)
6-31/32(177.2)
59/64(23.5)
19/32(15)
0
19/32(15)
5-5/16(135)
6-21/32(169.2)
8-49/64(222.7)
9-13/64(233.7)
10-3/16(258.7)
11-7/8(301.5)
5-5/16(135)
6-21/32(169.2)
8-49/64(222.7)
10-3/16(258.7)
11-21/64(287.7)
11-7/8(301.5)
(222.7)
8-49/64
0
(234.7)
9-15/64
12-61/64(329)
(66.3)
2-39/64
(79.3)
3-1/8
(220)
8-21/32
(386.5)
15-7/32
(386.5)
15-7/32
11-21/32(296)
(154)
6-1/16
25/32(20)
1-21/32(50)
3-27/64(87)
(67)
2-41/64
2-9/16(65)
25/64(10)
1-27/32
(47)
(59)
2-21/64
(70)
2-3/4
(50)
1-31/32
25/64(10)
2-9/16(65)
3/4(19)
2-3/4(70)
1-61/64(49.5)
(67)
2-41/64
13/64(5)
9-11/32(237)
7-53/64(199)
20-43/64(525)
1-59/64(49)
30-7/16(773)
6-19/64(160)
7-1/64(178)
16-21/32(423)(LIQUID P
IPE)
14-11/64(360)(GAS P
IPE)
7-9/16(192)
(451) 17-3/4
(216.5) 8-17/32
(216.5) 8-17/32
9-27/32(250) MIN.
1-31/32(50) MIN.
9/32(7) MIN.
10-15/64(260) MIN.
5-29/32(150) MIN.
1-31/32(50) MIN.
(171)
6-47/64
29×
Ø 13/64 (
Ø5.1HOLE)
5×
Ø23/64(
Ø9HOLE)
11-25/32(299)
4× Ø
11/64(
Ø4.3HOLE)
(330)
12-63/64
SLEEVE
THROUGH HOLE
Ø2-61/64
(Ø
75)
Ø2-61/64
~
Ø3-5/32
(Ø
75 ~
Ø80)
REFRIGERANT PIP
ING
LIQUID P
IPE
Ø
1/4(
Ø
6.35)
GAS P
IPE
Ø
1/2(
Ø
12.7)
DRAIN HOSE
CONNECTION
Ø
5/8(
Ø
16)
INSULA
TION
Ø
1-9/64(
Ø
29)
INDOOR UNIT
INST
ALLA
TION PLA
TE
WALL HOLE
Ø2-61/64(
Ø75)
FOR RIGHT BACK P
IPING
WALL HOLE
Ø2-61/34(
Ø75)
FOR LEFT BACK P
IPING
B
C
POWER SUPPL
Y TERMINAL BLOCK
TRANSMISSION TERMINAL BLOCK
MA-REMOTE CONTROLLER TERMINAL BLOCK
EMERGENCY OPERA
TION SWITCH(HEA
T)
UNDER P
IPING CUT OUT AREA
UNDER P
IPING CUT OUT AREA
REFRIGERANT P
IPE,DRAIN P
IPE
REFRIGERANT P
IPE,DRAIN P
IPE
EMERGENCY OPERA
TION SWITCH(COOL)
RECEIVER
B
DET
AILS OF CUT OUT
FOR P
IPING HOLE
A
D
C
AUTO V
ANES
LOUVERS(MANUAL)
TOP
FRONT
FRONT(OPEN THE GRILLE)
BOT
TOM
RIGHT
OPERA
TING LAMP(GREEN)
ST
ANDBY LAMP(ORANGE)
A
INST
ALLA
TION PLA
TE
RIGHT P
IPING CUT OUT AREA
REFRIGERANT P
IPE,DRAIN P
IPE
REQUIRED SPACE(INDOOR UNIT
)
AIR INLET
AIR OUTLET
IN CASE OF OPTIONAL
DRAIN PUMP INSTALLA
TION,
9-27/32(250) MIN.
IN CASE OF LEFT PIPING,
LEFT BACK PIPING,2-11/64(55) MIN.
OR OPTIONAL DRAIN PUMP
INSTALLA
TION,2-61/64(75) MIN.
IN CASE OF OPTIONAL DRAIN PUMP INST
ALLA
TION,
13-25/32(350) MIN.
1. FOR CEILING CORNICE: CONSIDER THE DIMENSION FOR INST
ALLA
TION.
2. MOUNTING BOL
T FOR INST
ALLA
TION PLA
TE: M10 OR W3/8
T
APP
ING SCREW: NOMINAL DIAMETER
・・・
5/32(4)
LENGTH
・・・
63/64(25) MIN
SCREW TIGHT A
T INST
ALLA
TION PLA
TE HOLE
{11/64(
Ø 4.3)
}
ON THE UPPER AND LOWER SIDE EVENL
Y.
DO NOT SCREW TIGHT ONL
Y IN LINE.
3. 4. LEFT P
IPE: CONNECT DRAIN HOSE TO CONNECTION PORT
ON THE LEFT SIDE OF DRAIN PAN. EXCHANGE DRAIN HOSE AND RUBBER CAP AND BUT
T THEM AGAINST DRAIN PORT
.
5. DRAIN P
IPE EFFECTIVE LENGTH
・・・
19-11/16(500)
LEFT P
IPING CUT OUT AREA
REFRIGERANT P
IPE,DRAIN P
IPE
D
LEFT
TEMPORARIL
Y FIXING HOLE
DRAIN HOSE
WALL HOLE
Ø2-61/64(
Ø75)
FOR RIGHT BACK CONDIT CABLE
OUTLINES AND DIMENSIONS
5
PKFY-P04NLMU-E.TH
PKFY-P06NLMU-E.TH
PKFY-P08NLMU-E.TH
PKFY-P12NLMU-E.TH
Unit: inch(mm)