Before installing the unit, make sure you read all the “Safety
precautions”.
Ź
Please report to your supply authority or obtain their consent before
connecting this equipment to the power supply system.
Warning:
Describes precautions that must be observed to prevent danger of injury or
death to the user.
Caution:
Describes precautions that must be observed to prevent damage to the unit.
After installation work has been completed, explain the “Safety Precautions,” use,
and maintenance of the unit to the customer according to the information in the
Operation Manual and perform the test run to ensure normal operation. Both the
Installation Manual and Operation Manual must be given to the user for keeping.
These manuals must be passed on to subsequent users.
Contents
Warning:
Ask the dealer or an authorized technician to install the air conditioner.
The user should never attempt to repair the unit or transfer it to another
location.
Install the unit at a place that can withstand its weight.
Use only specified cables for wiring. The wiring connections must be
made securely with no tension applied on the terminal connections. Also,
never splice the cables for wiring (unless otherwise indicated in this docu-
ment).
Failure to observe these instructions may result in overheating or a fire.
Use only accessories authorized by Mitsubishi Electric and ask the dealer
or an authorized technician to install them.
Do not touch the heat e
[
changer fins.
Install the air conditioner according to this Installation Manual.
Have all electric work done by a licensed electrician according to local
regulations.
The appliance shall be installed in accordance with national wiring
regulations.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
If the air conditioner is installed in a small room, measures must be taken
to prevent the refrigerant concentration from e
[
ceeding the safety limit
even if the refrigerant should leak.
The cut face punched parts may cause injury by cut, etc. The installers are
requested to wear protective equipement such as gloves, etc.
When installing or relocating, or servicing the air conditioner, use only the
specified refrigerant (R410A) to charge the refrigerant lines. Do not mi
[
it
with any other refrigerant and do not allow air to remain in the lines.
If air is mi
[
ed with the refrigerant, then it can be the cause of abnormal
high pressure in the refrigerant line, and may result in an e
[
plosion and
other hazards.
The use of any refrigerant other than that specified for the system will
cause mechanical failure or system malfunction or unit breakdown. In the
worst case, this could lead to a serious impediment to securing product
safety.
1. Safety precautions
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts.
: Indicates that the main power switch must be turned off before servicing.
: Beware of electric shock.
: Beware of hot surface.
ELV
: At servicing, please shut down the power supply for both the Indoor and
Outdoor Unit.
Warning:
Carefully read the labels affi
[
ed to the main unit.
Caution:
Do not use the e
[
isting refrigerant piping, when use R410A refrigerant.
Use ester oil, either oil or alkylbenzene (small amount) as the refrigerator
oil to coat flares and flange connections, when use R410A refrigerant.
Do not use the air conditioner where food, pets, plants, precision
instruments, or artwork are kept.
Do not use the air conditioner in special environments.
Ground the unit.
Install an leak molded case circuit braker, as required.
Use power line cables of sufficient current carrying capacity and rating.
Use only a molded case circuit braker and fuse of the specified capacity.
Do not touch the switches with wet fingers.
Do not touch the refrigerant pipes during and immediately after operation.
Do not operate the air conditioner with the panels and guards removed.
Do not turn off the power immediately after stopping operation.
1. Safety
precautions
.............................................................................................2
2. Installation
location
............................................................................................3
3. Installing the indoor unit ....................................................................................3
4. Installing the refrigerant piping ..........................................................................7
5. Drainage piping work .........................................................................................9
6. Electrical
work
.................................................................................................10
7. Test
run
............................................................................................................13
Note:
The phrase “Wired remote controller” in this installation manual refers only to the PAR-
2MAA.
If you need any information for the other remote controller, please refer to either the installation manual or initial setting manual which are
included in these bo
[
es.