1
Adjusting conditions
Adjustments should be carried out in accordance with the procedures described below. However, any adjustments
other than the items A to C below are not required.
A. When the [PDP module] is replaced, adjust the sections according to the adjusting items [1 to 3] specified below.
(Caution)
When the PDP module has been replaced, clear the USAGE TIME to “0” without fail, according to
“how to clear the usage time” shown below.
B. When the [POWER unit] is replaced, adjust the sections according to the adjusting items [1 to 3] specified below.
C. When the [MAIN PWB] is replaced, adjust the sections according to the adjusting item [4 and 5] specified below.
* How to clear the integrated time
Assume the folloing factory mode by the use of the remote control. Press [MENU/ENTER] key six times to
the screen [USAGE TIME]. In this state, the integrated time up to the present time is displayed.
The integrated time is cleared to [0] when the remote control keys are pressed in the order of [MUTE]
®
cursor keys [ ]
®
cursor keys [V]
®
[SLEEP].
*
How to enter or withdraw from the factory setting mode:
Press the keys in the sequential order of [SLEEP] [EXIT] [MUTE] [SLEEP].
When a conventional remote control is used:
Press the keys in the sequential order of [OFF TIMER]
®
[OK]
®
[MUTE]
®
[OFF TIMER].
At that time, use the [MENU] key in place of the [PROCEED] key.
1. Adjustment of +170V
(1) Using any video signal of VIDEO input, DVD/HD input, or RGB input, and display a color bar signal. Turn on
the power switch of the main unit.
(2) Turn the volume control (RV3) in the [D+170V ADJ] section of the power unit, and adjust the voltage value
between TP3 (D+170V output) and TP2 (D.GND) of the power unit so that this voltage settles within the
range of “specified voltage of the PDP module (Value Vs on the label shown below)
±
1V.”
(Caution)
The figure below shows a rear side view when the
back cover has been removed.
V
SERIAL NO.
** ** ** ** *
Vd=* *V
Vs=* ** V
CODE -01
Содержание PD-5010
Страница 2: ......
Страница 11: ...TROUBLESHOOTING 3 1 ...
Страница 27: ...METHOD OF ADJUSTMENTS 4 1 ...
Страница 54: ...PACKAGING 6 1 ...
Страница 56: ...PLUG CABLE POWER CORD REM T HAND UNIT CABLE D SUB 15P L1800 ACCESSORY BOX BAG B 4 ACCESSORY BOX 2 BAG BAG C ...
Страница 58: ...4 BACK STOPPER TAPE PP BAND JOINT BAR CODE SERIAL LABEL ...
Страница 61: ...CONNECTION DIAGRAMS 8 1 ...
Страница 73: ...BLOCK DIAGRAMS 9 1 ...