14
6. Test Run
After refiling batteries.
Press the reset button.
Reset
2
1
0
9
8
7
6
5
4
3
Nrm
Set
NOT AVAILABLE
˚C
AM
PM
AM
PM
CHECK
TEST RUN
ON/OFF
ON/OFF
NOT AVAILABLE
˚C
AM
PM
AM
PM
CHECK
TEST RUN
CLOCK
MODE
FAN
VANE
STOP
START
HR.
MIN.
7
B
8
3
6
45
2
9
A
1
Turn on the main power to the unit.
2
Set the Nrm/Set selector switch (on the back of the controller) to «Set».
A
The
CHECK
and
TEST RUN
begin to blink.
3
Press the
MIN.
button.
B
TEST RUN
and current operation mode are displayed.
4
Press the MODE (
) button to activate FAN
mode, then check whether air is blown out
from the unit.
5
Press the MODE (
) button to activate COOL
mode, then check whether cool air is
blown out from the unit.
6
Press the FAN
button and check whether strong air is blown out from the unit.
7
Press the VANE
button and check whether the auto vane operates properly.
8
Press the
ON/OFF button to stop the test run.
9
After test run is complete, set the Nrm/Set selector switch to «Nrm».
Note:
Point the remote controller toward the receiver while following steps
3
though
8
.