12
REFRIGERANT SYSTEM DIAGRAM
8
Unit: mm
MUZ-RW25VGHZ
MUZ-RW35VGHZ
MUZ-RW50VGHZ
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø9.52
(with heat insulator)
Refrigerant pipe ø6.35
(with heat insulator)
R.V. coil
heating ON
cooling OFF
Strainer
#100
LEV
Ambient
temperature
thermistor
RT65
Strainer
#100
Capillary tube
ø4.0×ø2.4×100
Outdoor heat
exchanger
temperature
thermistor
RT68
Capillary tube
ø3.0×ø2.0×240
Muffler
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
Capillary tube
ø4.0×ø2.4×240
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
ø9.52
(with heat insulator)
Refrigerant pipe ø6.35
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
Strainer
#100
Muffler
Capillary tube
ø3.0×ø2.0×210 (x 2)
Muffler
OBH903