6
The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed posi-
tion.
The coverage should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
3-2. OUTLET AIR SPEED AND COVERAGE
1. Single connection
Model
Mode
Function
Air
À
ow
(CFM)
Air speed
(ft./s.)
Coverage (ft.)
MFZ-KJ09NA
MFZ-KJ12NA
HEAT
Dry
417
20.3
29.6
COOL
Dry
417
20.3
29.6
Wet
354
17.2
25.3
MFZ-KJ15NA
HEAT
Dry
470
22.9
33.3
COOL
Dry
431
21.0
30.6
Wet
366
17.8
26.2
MFZ-KJ18NA
HEAT
Dry
470
22.9
33.3
COOL
Dry
491
23.9
34.8
Wet
417
20.3
29.7
2. Multi connection
Model
Mode
Function
Air
À
ow
(CFM)
Air speed
(ft./s.)
Coverage (ft.)
MFZ-KJ09NA
MFZ-KJ12NA
HEAT
Dry
343
16.7
24.5
COOL
Dry
275
13.4
19.8
Wet
234
11.4
16.9
MFZ-KJ15NA
MFZ-KJ18NA
HEAT
Dry
470
22.9
33.3
COOL
Dry
374
18.2
26.7
Wet
318
15.5
22.8
(2) OPERATION
Mode
Condition
Intake air temperature (°F)
Indoor
Outdoor
DB
WB
DB
WB
Cooling
Standard temperature
80
67
95
—
Maximum temperature
90
73
115
—
Minimum temperature
67
57
14
—
Maximum humidity
78%
—
Heating
Standard temperature
70
60
47
43
Maximum temperature
80
67
75
65
Minimum temperature
70
60
-13
-14
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Guaranteed voltage (V)
Indoor unit
208/230 V
1 phase
60 Hz
Min. 187
208
230
Max. 253
2%+%