![Mitsubishi Electric MUFZ-KJ-NAHZ Series Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/mitsubishi-electric/mufz-kj-nahz-series/mufz-kj-nahz-series_service-manual_1810854010.webp)
10
SERVICE FUNCTIONS
7
7-1. TIMER SHORT MODE
• For service, the following set time can be shortened by bridging the timer short mode point on the electronic control P.C.
board. (Refer to 9-7.)
• The set time for the ON/OFF timer can be reduced to 1 second for each minute.
• After the breaker is turned on, the time for starting the compressor, which normally takes 3 minutes, can be reduced to 3
seconds. Restarting the compressor, which takes 3 minutes, cannot be reduced.
MFZ-KJ09NA MFZ-KJ12NA MFZ-KJ15NA MFZ-KJ18NA
1. How to modify the electronic control P.C. board
Turn OFF the power supply before modification. To assign a number to each indoor unit , cut off “JR05” and “JR06” on the
electronic control P.C. board as shown in Table 1. (Refer to 9-7.)
Unit No. 1
Unit No. 2
Unit No. 3
Unit No. 4
JR05
No modification
Cut off JR05
No modification
Cut off JR05
JR06
No modification
No modification
Cut off JR06
Cut off JR06
Table 1
CN211
Fuse (F11)
VARISTOR (NR11)
Indoor electronic
control P.C. Board
CN151
JR05
JR06
R111
7-2. HOW TO SET REMOTE CONTROLLER EXCLUSIVELY FOR A PARTICULAR INDOOR UNIT
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
To operate the indoor units individually with each remote controller, assign a number to each remote controller according
to the number of the indoor unit.
This setting can be set only when all the following conditions are met:
• The remote controller is powered OFF.
• Weekly timer is not set.
• Weekly timer is not being edited.
2. How to set the remote controller
(1) Hold down
button on the remote controller for 2 seconds to enter the pairing mode.
(2) Press
button again and assign a number to each remote controller.
Each press of
button advances the number in the following order: 1
ĺ
2
ĺ
3
ĺ
4.
(3) Press
button to complete the pairing setting.
After the setting, turn ON the power supply and with the remote controller headed towards the indoor unit, press the
STOP/OPERATE (OFF/ON) button. If 1 or 2 beeps are heard from the indoor unit, the setting is completed correctly.
The remote controller that first sends a signal to an indoor unit will be regarded as the remote controller for the indoor
unit.
Once they are set, the indoor unit will only receive the signal from the assigned remote controller afterwards.