21
Compressor
(MC)
INNER
PROTECTOR
160
i
5
:
OPEN
90
i
10
:
CLOSE
11-3. Trouble criterion of main parts
Part name
Outdoor fan
motor
(MF)
INNER
PROTECTOR
145
i
8
:
OPEN
( 88
i
15
:
CLOSE
w
)
Check method and criterion
Measure the resistance between the terminals with a tester.
(Part temperature -10°C ~ 40°C)
Measure the resistance between the terminals with a tester.
(Part temperature -10°C ~ 40°C)
Figure
C
S
R
BLK
RED
WHT
Color of lead
wire
Normal
MUCFH-A18WV
1.05 ~ 1.30
Ω
2.38 ~ 2.92
Ω
C-R
C-S
Normal
Abnormal
Open or
short-circuit
102 ~ 126
Ω
97 ~ 120
Ω
MUCFH-A18WV
WHT-BLK
BLK-RED
Abnormal
Open or
short-circuit
MUCFH-A18WV
BLK
REDORN WHT
MAIN
AUX
P
: INNER PROTECTOR
P
MUCFH-A24WV
0.84 ~ 1.04
Ω
1.82 ~ 2.24
Ω
55 ~ 68
Ω
MUCFH-A24WV
BLK-YLW
YLW-RED
26 ~ 33
Ω
55 ~ 68
Ω
MUCFH-A24WV
BLK YLW RED ORN WHT
MAIN
AUX.2
AUX.1
P
Defrost
thermistor (RT61)
Measure the resistance with a tester.
(Part temperature -10°C ~ 40°C)
Normal
5k
Ω
~ 60k
Ω
Abnormal
Open or short-circuit
Ambient temper-
ature thermistor
(RT63)
MUCFH-A24WV
Color of lead
wire
R.V. coil
(21S4)
Normal
2.673k
Ω
~ 3.268k
Ω
Abnormal
Open or short-circuit
Measure the resistance using a tester. (Part temperature -10°C ~ 40°C)
MUCFH-A18WV -
MUCFH-A24WV -
E1
E1
w
Reference value
OB337B--1.qxp 05.7.6 11:00 AM Page 21