![Mitsubishi Electric MSZ-HJ VA Series Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/mitsubishi-electric/msz-hj-va-series/msz-hj-va-series_service-manual_1810730050.webp)
50
Check the outdoor fan motor.
(Refer to 11-5. .)
Is the fuse (F901) blown on the in-
verter P.C. board?
Check the connection of the connectors
(CN931, CN932) of the outdoor fan motor.
If the connection is poor, make it correct.
Operate the outdoor unit by starting
EMERGENCY OPERATION.
Check the LED indication on the in-
verter P.C. board.
Does the LED fl ash 10 times?
Replace the inverter P.C. board.
Check the corresponding parts
following LED indication.
(Refer to 11-3.)
Yes
No
Yes
(10-time fl ash)
No
L Check of inverter P.C. board
MUZ-HJ50VA MUZ-HJ60VA MUZ-HJ71VA
OBH648F