MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
Refrigerant piping: m
Piping size O.D: mm
Max. Length
A
Max. Height difference
B
Gas
Liquid
MUZ-HJ25VA
MUZ-HJ35VA
20
12
9.52
6.35
MUZ-HJ50VA
12.7
MUZ-HJ60VA
MUZ-HJ71VA
30
15
15.88
9.52
Max. Length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
ADDITIONAL REFRIGERANT CHARGE (R410A : g)
Model
Outdoor unit
precharged
Refrigerant piping length (one way)
5 m
6 m
7 m
8 m
9 m
10 m
11 m
12 m
13 m
14 m
15 m
20 m
MUZ-HJ25VA
700
0
0
0
20
40
60
80
100
120
140
160
260
MUZ-HJ35VA
720
MUZ-HJ50VA
1,150
MUZ-HJ60VA
1,800
MUZ-HJ71VA
1,800
Calculation: X g = 20 g/m (Refrigerant piping length (m) - 7)
NOTE :
Refrigerant piping exceeding 7 m requires additional refrigerant charge according to the calculation.
MUZ-HJ60VA MUZ-HJ71VA
Unit: mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
Capillary tube
ø4.0×ø2.4×100
Capillary tube
ø4.0×ø2.4×200
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø15.88
(with heat insulator)
Refrigerant pipe ø6.35(
HJ60
)
Refrigerant pipe ø9.52(
HJ71
)
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Strainer
#100
Outdoor heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Muffler
Capillary tube
ø3.0×ø2.0×200(×4)
OBH648F
Содержание MSZ-HJ VA Series
Страница 12: ...12 MUZ HJ25VA E1 ER1 ET1 6 WIRING DIAGRAM MUZ HJ25VA E2 ER2 ET2 OBH648F ...
Страница 13: ...13 MUZ HJ35VA E1 ER1 ET1 MUZ HJ35VA E3 ER3 ET2 OBH648F ...
Страница 14: ...14 MUZ HJ50VA E1 ER1 ET1 MUZ HJ50VA E2 ER2 ET2 MUZ HJ60VA E2 MUZ HJ71VA E2 OBH648F ...
Страница 15: ...15 MUZ HJ60VA E1 ER1 ET1 MUZ HJ71VA E1 ER1 ET1 OBH648F ...
Страница 65: ...65 OBH648F ...