5
Indoor model
MSZ-GE22VA
MSZ-GE25VA
MSZ-GE35VA
MSZ-GE42VA
MSZ-GE50VA
Power supply
Single phase 230 V, 50 Hz
Electrical data
Power
input 1
Cooling
W
22
29
43
Heating
23
30
39
Running
current 1
Cooling
A
0.22
0.29
0.39
Heating
0.23
0.31
0.36
Fan motor
Model
RC0J40-FK
Current
1
Cooling
A
0.22
0.29
0.39
Heating
0.23
0.31
0.36
Dimensions W × H × D
mm
798 × 295 × 232
Weight
kg
10
Special remarks
Air direction
5
Air
fl
ow
Cooling
Super High
m
3
/h
678
762
768
906
High
546 (552 2)
624
714
Med.
402
402 (414 2)
516
576
Low
288 (276 2)
288
408
468
Silent
246
348
390
Heating
Super High
m
3
/h
690
786
870
High
546
624
732
Med.
396
402
516
576
Low
288 (276 2)
288
420
468
Silent
246
348
390
Sound level
Cooling
Super High
dB(A)
42
43
46
49
High
36
40
44
Med.
29
30
35
38
Low
21
22
30
33
Silent
19
26
28
Heating
Super High
dB(A)
42
46
48
High
36
40
43
Med.
29
30
35
37
Low
21
22
30
33
Silent
19
26
28
Fan speed
Cooling
Super High
rpm
1,020
1,120
1,120
1,280
High
860
950
1,060
Med.
670
670 (690 2)
810
890
Low
530
680
750
Silent
470
600
650 (690 2)
Heating
Super High
rpm
1,040
1,140
1,240
High
860 (700 2)
950 (930 2)
1,080 (930 2)
Med.
670 (610 2)
810
890 (840 2)
Low
530
690
750
Silent
470
600
650
Fan speed regulator
5
Remote controller model
KM09A
NOTE
: Test conditions are based on ISO 5151.
Cooling: Indoor
Dry-bulb temperature 27°C
Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor
Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C
Wet-bulb temperature 6°C
1 Measured under rated operating frequency.
2 For multi system.
Specifications and rating conditions of main electric parts
Fuse
(F11)
T3.15AL250V
Horizontal vane motor
(MV)
12 VDC
Varistor
(NR11)
S10K300E3K1 (ERZV14D471)
Terminal block
(TB)
3P
SPECIFICATION
3
Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com