30
1. Indoor power P.C. board, Indoor terminal P.C. board
MSZ-GE22VA MSZ-GE25VA MSZ-GE35VA
10-7. Test point diagram and voltage
Indoor terminal P.C. board
Indoor power P.C. board
Please replace the fuse after removing the indoor terminal P.C. board from the electrical box.
Fuse (F11)( )
Varistor (NR11)
Terminal
block
Connector to indoor electronic
control P.C. board (CN20A)
5 VDC
12 VDC
GND
Resistor (R111)
Indoor fan motor
(CN211)
325 VDC
(–) GND (high-
voltage DC)
15 VDC
(+)3-6 VDC
(+)0-6 V
MSZ-GE42VA MSZ-GE50VA
Indoor terminal P.C. board
Indoor power P.C. board
Please replace the fuse after removing the indoor terminal P.C. board from the electrical box.
Fuse (F11)( )
Varistor (NR11)
Terminal
block
Connector to indoor electronic
control P.C. board (CN20A)
5 VDC
12 VDC
GND
Reactor (L111)
Indoor fan motor
(CN211)
325 VDC
(–) GND (high-
voltage DC)
15 VDC
(+)3-6 VDC
(+)0-6 V
Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy