● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?
•  Is the power supply plug connected?
•  Is the ON timer set? 

 Page 6 

The horizontal vane does not 
move.

•  Are the horizontal vane and the vertical vane 

installed correctly?

•  Is the fan guard deformed? 
•  When the breaker is turned on, the horizontal 

vanes’ position will be reset in about a minute. 
After the reset has completed, the normal hori-
zontal vanes’ operation resumes. The same is 
true in the emergency cooling operation.

The unit cannot be operated for 
about 3 minutes when restarted.

•  This protects the unit according to instructions 

from the microprocessor. Please wait.

Mist is discharged from the air 
outlet of the indoor unit.

•  The cool air from the unit rapidly cools moisture 

in the air inside the room, and it turns into mist.

The swing operation of the HOR-
IZONTAL VANE is suspended 
for a while, then restarted.

•  This is for the swing operation of the HORIZON-

TAL VANE to be performed normally.

When SWING is selected in 
COOL/DRY/FAN mode, the lower 
horizontal vane does not move.

•  It is normal that the lower horizontal vane does 

not move when SWING is selected in COOL/
DRY/FAN mode.

The airfl ow direction changes 
during operation.
The direction of the horizontal 
vane cannot be adjusted with 
the remote controller.

•  When the unit is operated in COOL or DRY 

mode, if the operation continues with air blowing 
down for 0.5 to 1 hour, the direction of the airfl ow 
is automatically set to horizontal position to 
prevent water from condensing and dripping.

•  In the heating operation, if the airfl ow tem-

perature is too low or when defrosting is being 
done, the horizontal vane is automatically set 
to horizontal position.

The operation stops for about 
10 minutes in the heating 
operation.

•  Outdoor unit is in defrost.
  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature is too 
low and humidity is too high, frost is formed.)

The unit starts operation by 
itself when the main power is 
turned on, but hasn’t received 
sign from the remote control-
ler.

•  These models are equipped with an auto 

restart function. When the main power is 
turned off without stopping the unit with the 
remote controller and is turned on again, the 
unit starts operation automatically in the same 
mode as the one set with the remote control-
ler just before the shutoff of the main power. 
Refer to “Auto restart function” 

 page 4 

.

The two horizontal vanes touch 
each other. The horizontal vanes 
are in an abnormal position. The 
horizontal vanes do not return to 
the correct “close position”.

Perform one of the following: 
•  Turn off and on the breaker. Make sure the horizon-

tal vanes move to the correct “close position”.

•  Start and stop the emergency cooling operation 

and make sure the horizontal vanes move to the 
correct “close position”.

In COOL/DRY mode, when the 
room temperature reaches near 
the set temperature, the outdoor 
unit stops, then the indoor unit 
operates at low speed.

•  When the room temperature deviates from the 

set temperature, the indoor fan starts running 
according to the settings on the remote control-
ler.

The indoor unit discolors over 
time.

•  Although plastic turns yellow due to the infl uence 

of some factors such as ultraviolet light and 
temperature, this has no effect on the product 
functions.

Multi system

The indoor unit which is not 
operating becomes warm and 
a sound, similar to water fl ow-
ing, is heard from the unit.

•  A small amount of refrigerant continues to fl ow 

into the indoor unit even though it is not operat-
ing.

When heating operation is 
selected, operation does not 
start right away.

•  When operation is started during defrosting of 

outdoor unit is done, it takes a few minutes (max. 
10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit 
does not rotate even though 
the compressor is running. 
Even if the fan starts to rotate, 
it stops soon.

•  When the outside temperature is low during 

cooling operation, the fan operates intermittently 
to maintain suffi cient cooling capacity.

Water leaks from the outdoor 
unit.

•  During COOL and DRY operations, pipe or pipe 

connecting sections are cooled and this causes 
water to condense.

•  In the heating operation, water condensed on 

the heat exchanger drips down.

•  In the heating operation, the defrosting operation 

makes ice forming on the outdoor unit melt and 
drip down.

White smoke is discharged 
from the outdoor unit.

•  In the heating operation, vapor generated by the 

defrosting operation looks like white smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 
controller does not appear 
or it is dim. The indoor unit 
does not respond to the 
remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct?

 Page 3 

•  Are any buttons on the remote controller of other 

electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 
or heated suffi ciently.

• Is the temperature setting appropriate? 

 Page 4 

•  Is the fan setting appropriate? Please change 

fan speed to higher setting. 

 Page 5 

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  Are there any obstacles blocking the air inlet or 

outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 
suffi ciently.

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 
in an insuffi cient cooling effect.

•  When the outside temperature is high, the cooling 

effect may not be suffi cient.

The room cannot be heated 
suffi ciently.

•  When the outside temperature is low, the heating 

effect may not be suffi cient.

Air does not blow out soon in 
the heating operation.

•  Please wait as the unit is preparing to blow out 

warm air.

Airfl ow

The air from the indoor unit 
smells strange.

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it out 
with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in 
temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on the 
range hood or the ventilation fan, making water 
fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 
wind is strong.

Mechanical sound is heard 
from the indoor unit.

•  This is the switching sound in turning on/off the 

fan or the compressor.

The sound of water fl owing 
is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 
heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is changed.

Timer

Weekly timer does not oper-
ate according to settings.

•  Is the ON/OFF timer set? 

 Page 6 

•  Transmit the setting information of the weekly 

timer to the indoor unit again. When the infor-
mation is successfully received, a long beep will 
sound from the indoor unit. If information fails to 
be received, 3 short beeps will be heard. Ensure 
information is successfully received. 

 Page 7 

•  When a power failure occurs and the main power 

turns off, the indoor unit built-in clock will be 
incorrect. As a result, the weekly timer may not 
work normally.

  Be sure to place the remote controller where 

the signal can be received by the indoor unit.

 Page 3 

The unit starts/stops the 
operation by itself.

•  Is the weekly timer set? 

 Page 7 

In the following cases, stop using the air conditioner and consult your 
dealer.

•  When water leaks or drips from the indoor unit.
•  When the left operation indicator lamp blinks.
•  When the breaker trips frequently.
•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Содержание MSZ-EF22VEB

Страница 1: ...struções de operação antes da utilização ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Για το χρήστη Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES...

Страница 2: ... manual in a handy place for easy reference Marks and their meanings WARNING Incorrect handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high ...

Страница 3: ...ulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly with clean water If the battery fluid comes in contact with your eyes wash them thoroughly with clean wa...

Страница 4: ...ng Drainage hose Air outlet Drain outlet Outdoor units may be different in appearance 1 Press CLOCK 4 Press CLOCK again 2 Press either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is...

Страница 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Страница 6: ...g the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Silent Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction AUTO The van...

Страница 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Страница 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Страница 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Страница 10: ...nning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips dow...

Страница 11: ...e air filter Page 8 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly 4 Refer to the PREPARATION BEFORE OPERATION and follow the instructions Page 3 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Note 1 Rating condition Cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB Heating Indoor 20 C DB Outdoor 7 C...

Страница 12: ... предназначено для использования людь ми включая детей с ограниченными физическими сенсорными или психическими возможностями При недостатке опыта и знаний разрешается пользоваться данным устройством только под наблюдением лица ответственного за безопасность или после инструктажа по использованию прибора Дети должны быть под присмотром и не играть с устройс твом Запрещается вставлять пальцы палки и...

Страница 13: ...той водой и сразу же обратитесь к врачу Убедитесь что место хорошо вентилируется при работе блока с легковоспламеняющимися приборами Недостаточная вентиляция может привести к кислородному голо данию Установите выключатель в положение OFF во время грозы и при вероятности удара молнии Удар молнии может привести к повреждению блока После использования кондиционера в течение нескольких сезо нов выполн...

Страница 14: ...ения Внешний вид устройств предназначенных для использования на улице может отличаться 1 Снимите переднюю крышку 2 Вставьте ще лочные бата рейки типа AAA 3 Установите переднюю крышку 4 Нажмите кнопку RESET Излучатель сигналов Расстояние сигнала приблизитель но 6 м Звук воспроизводится внутренним бло ком при получении сигнала Сектор рабо чего дисплея Кнопка ON OFF работа останов Кнопки регулиро ван...

Страница 15: ... Нажмите чтобы остановить работу Функция повторного автозапуска Если произошел сбой питания или электропитание прибора было выклю чено во время его работы функция повторного автозапуска автомати чески настраивает прибор на работу в том режиме который был задан с помощью пульта дистанционного управления до отключения электропи тания Когда таймер установлен настройка таймера отменяется и блок начина...

Страница 16: ...ости При установке в положение включения выключателя положение горизонтальных заслонок будет сброшено приблизительно через минуту после чего они начнут работу Заслонки функционируют аналогичным образом и в режиме аварийного охлаждения Если горизонтальные заслонки находятся в положении которое кажется необычным см стр 9 НАСТРОЙКА СКОРОСТИ ВЕНТИЛЯТОРА И НАПРАВЛЕНИЯ ВОЗДУШНОГО ПОТОКА AUTO Бесшумный р...

Страница 17: ...можно за дать температуру 10 C Даже если температура задана равной 10 C кон диционер будет работать поддерживая температуру 16 C ФУНКЦИЯ ECONO COOL В режиме COOL нажмите cтр 4 чтобы запустить функцию ECONO COOL В соответствии с температурой потока воздуха в различных циклах прибор будет работать в режиме вертикального качания Снова нажмите чтобы отменить функцию ECONO COOL Режим ECONO COOL выключа...

Страница 18: ... нажмите чтобы ВЫКЛЮЧИТЬ OFF недельный таймер гаснет Примечание Сохраненные настройки не удаляются при ВЫКЛЮЧЕННОМ OFF недельном таймере Проверка настройки недельного таймера 1 Нажмите чтобы перейти в режим настройки недельного таймера мигает 2 Нажмите или чтобы просмотреть на стройки для конкретного дня или номера дня недели Нажмите чтобы выйти из режима настроек недельного таймера Примечание Есл...

Страница 19: ...я наночастицу платины Частицы включены в материал фильтра что обеспечивает полупостоянные антибактериальные и дезодорирующие свойства фильтра Частица Niño platinum превосходит по своим характеристикам катехин био флавоноид содержащийся в зеленом чае В фильтре Niño platinum данное химическое соединение используется не только для улучшения качества воздуха но и для удаления бактерий и вирусов Эти по...

Страница 20: ...несколько минут макс 10 минут Наружный прибор Вентилятор наружного прибора не вращается даже когда ком прессор работает Даже когда вентилятор начинает вращаться он быстро останавливается В режиме охлаждения при низкой температуре наружного воздуха вентилятор может вклю чаться и выключаться чтобы поддерживать достаточную мощность охлаждения Из наружного прибора вытекает вода При работе в режимах CO...

Страница 21: ... прибора предназначена только для мультисис темного кондиционера По вопросам технических характеристик мультисистемной моде ли обратитесь к своему дилеру и или см каталог Гарантированный рабочий диапазон DB сухой термометр WB влажный термометр Устанавливайте как можно дальше для защиты от воздействия люминесцентных ламп стена и т п Люминесцентная лампа инверторного типа Обеспечьте достаточное расс...

Страница 22: ......

Страница 23: ...r samt kommersielle og lettindustrielle miljøer Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numéro de série de l appareil se trouve sur la plaque du produit Opmerking het serienummer staat op het naamplaatje van het product Nota El número de serie se encuentra en la placa que contiene el nombre del prod...

Отзывы: