C

LEANING

•  Switch off the power supply or turn off the breaker before cleaning.

•  Be careful not to touch the metal parts with your hands.

•  Do not use benzine, thinner, polishing powder, or insecticide.

•  Use only diluted mild detergents.

•  Do not expose parts to direct sunlight, heat, or fi re to dry.

•  Do not use water hotter than 50°C.

Air fi lter (Nano platinum fi lter)

• 

 

Clean every 2 weeks

 

•  Remove dirt by a vacuum cleaner, or rinse with water.

•  After washing with water, dry it well in shade.

 Important

• 

Clean the fi lters regularly for best performance and to 

reduce power consumption.

• 

Dirty  fi lters  cause  condensation  in  the  air  conditioner 

which  will  contribute  to  the  growth  of  fungi  such  as 

mold.  It  is  therefore  recommended  to  clean  air  fi lters 

every 2 weeks.

Front panel

1. Lift the front panel until a “click” is heard.

2. Close the front panel securely and press the 

positions indicated by the arrows.

3. Clean the front panel without detaching it 

from the unit.

•  Wipe with a soft dry cloth. A dedicated soft dry cloth is only provided with 

MSZ-EF**VAB type.

•  Use the dedicated SOFT DRY CLOTH. Parts Number 

 MAC-1001CL-E 

•  Do not soak the front panel in water.

Air cleaning fi lter 

(Electrostatic anti-allergy enzyme fi lter, 

option)

Every 3 months:

•  Remove dirt by a vacuum cleaner.

When dirt cannot be removed by vacuum cleaning:

•  Soak the fi lter and its frame in lukewarm water before rinsing it.

•  After washing, dry it well in shade. Install 

all tabs of the air fi lter.

Every year:

•  Replace it with a new air cleaning fi lter 

for best performance.

•  Parts Number 

 MAC-2320FT 

Pull to remove from the air fi lter

What is “Nano platinum fi lter”?

Nano platinum is a ceramic particle that includes a platinum nanoparticle. 

The particles are incorporated into the fi lter material, which results in pro-

viding semi-permanent antibacterial and deodorizing characteristics for the 

fi lter. Nano platinum surpasses the catechin (a biofl avonoid that is found 

in green tea) in performance. Nano platinum fi lter uses this compound not 

only to improve air quality but also to eliminate bacteria and viruses. This air 

fi lter has a semi-permanent lasting effect even after washing it with water.

 Important

• 

The  surface  of  the  indoor  unit  is  easily  scratched,  so 

never  rub  or  hit  the  unit  with  something  hard.  Also, 

when  installing  or  removing  the  front  panel,  handle  it 

with care to prevent scratches on it.

• 

Do not use abrasive cleaner to prevent scratches on the 

surface of the indoor unit.

• 

It is very easy to get fi ngerprints on the surface of the 

indoor  unit.  When  fi ngerprints  are  noticeable,  gently 

wipe them off with a soft dry cloth.

• 

When using a commercially available chemical impreg-

nated cloth, follow its instructions.

• 

Do not leave the front panel open for a prolonged time.

SG79F596H01_en.indd   8

2011/03/15   7:56:27

Содержание MSZ-EF22VAB

Страница 1: ...MSZ EF42VAW MSZ EF50VAW MSZ EF22VAB MSZ EF25VAB MSZ EF35VAB MSZ EF42VAB MSZ EF50VAB MSZ EF22VAS MSZ EF25VAS MSZ EF35VAS MSZ EF42VAS MSZ EF50VAS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...ct handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell sto...

Страница 3: ...unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance which require sp...

Страница 4: ...s either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature b...

Страница 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Страница 6: ...ir flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Quiet Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction ...

Страница 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Страница 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Страница 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Страница 10: ...unning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips do...

Страница 11: ... the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such a...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F596H01 ...

Отзывы: