Mitsubishi Electric MSZ-EF22VAB Скачать руководство пользователя страница 4

En-3

● OPERATING INSTRUCTIONS ●

•   Make sure the polarity of the batteries is correct.

•  

Do not use manganese batteries and leaking batteries. The remote controller 

could malfunction.

•   Do not use rechargeable batteries.

•   Replace all batteries with new ones of the same type.

•  Batteries can be used for approximately 1 year. However, batteries with 

expired shelf lives last shorter.

•  Press RESET gently using a thin instrument.

  If the RESET button is not pressed, the remote controller may not operate 

correctly.

Before operation:

 Insert the power supply plug into the power outlet and/or turn the breaker on.

•  Press CLOCK gently using a thin instrument.

Operation 

indicator lamp

Remote control 

receiving section

Emergency 

operation 

switch 

 Page 4 

Horizontal vane

Air inlet

Air fi lter

(Nano platinum fi lter)

Air cleaning fi lter

(Electrostatic anti-allergy 

enzyme fi lter, option)

Heat exchanger

Front panel

Installing the remote controller batteries

Setting current time

N

AME OF EACH PART

P

REPARATION BEFORE OPERATION

Indoor unit

Remote controller

1.

 

Remove the front lid

2.

 Insert  AAA

alkaline batteries

3.

 Install the front lid

4.

 

Press RESET

1.

 Press CLOCK

4.

 Press CLOCK again

2.

 Press either the TIME button or 

the TIMER buttons to set the 

time.

 

Each press increases/decreases 

the time by 1 minute (10 minutes 

when pressed longer)

3.

 Press the DAY button 

to set the day

Remote controller holder

Signal transmitting 

section

Distance of signal : 

About 6 m

Beep(s) is (are) heard 

from the indoor unit 

when the signal is 

received.

Operation 

display section

ON/OFF

(operate/stop) button

Temperature 

buttons 

 Page 4 

Operation 

select button 

 Page 4 

ECONO COOL 

button 

 Page 6 

FAN speed control 

button 

 Page 5 

VANE control button 

 Page 5 

TIME, TIMER set buttons 

 Pages 3, 6 

  Increase time

  Decrease time

CLOCK button 

 Page 3 

RESET button 

 Page 3 

Lid

Slide the lid down to open 

the remote controller. Slide 

it down further to get to the 

weekly timer buttons.

•  Install the remote con-

troller holder in a place 

where the signal can be 

received by the indoor 

unit.

•  When the remote con-

troller is not used, place 

it in this holder.

If two or more indoor units are 

installed in proximity to one another, 

an indoor unit that is not intended 

to be operated may respond to the 

remote controller.

i-save button 

 Page 6 

WEEKLY TIMER

set buttons 

 Page 7 

Air outlet

Air inlet  (back and side)

Piping

Drainage hose

Air outlet

Drain outlet

Outdoor unit

Outdoor units may be different in appearance.

Only use the remote controller 

provided with the unit.

Do not use other remote controllers.

SG79F596H01_en.indd   3

2011/03/15   9:22:48

Содержание MSZ-EF22VAB

Страница 1: ...MSZ EF42VAW MSZ EF50VAW MSZ EF22VAB MSZ EF25VAB MSZ EF35VAB MSZ EF42VAB MSZ EF50VAB MSZ EF22VAS MSZ EF25VAS MSZ EF35VAS MSZ EF42VAS MSZ EF50VAS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...ct handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell sto...

Страница 3: ...unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance which require sp...

Страница 4: ...s either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature b...

Страница 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Страница 6: ...ir flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Quiet Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction ...

Страница 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Страница 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Страница 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Страница 10: ...unning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips do...

Страница 11: ... the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such a...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F596H01 ...

Отзывы: