● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 6 

The horizontal vane does not 

move.

•  Are the horizontal vane and the vertical vane 

installed correctly?

•  Is the fan guard deformed? 

•  When the breaker is turned on, the horizontal 

vanes’ position will be reset in about a minute. 

After the reset has completed, the normal hori-

zontal vanes’ operation resumes. The same is 

true in the emergency cooling operation.

The unit cannot be operated for 

about 3 minutes when restarted.

•  This protects the unit according to instructions 

from the microprocessor. Please wait.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools moisture 

in the air inside the room, and it turns into mist.

The swing operation of the HOR-

IZONTAL VANE is suspended 

for a while, then restarted.

•  This is for the swing operation of the HORIZON-

TAL VANE to be performed normally.

When SWING is selected in 

COOL/DRY/FAN mode, the 

lower horizontal vane does 

not move.

•  It is normal that the lower horizontal vane does 

not move when SWING is selected in COOL/

DRY/FAN mode.

The airfl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When  the  unit  is  operated  in  COOL  or  DRY 

mode, if the operation continues with air blowing 

down for 0.5 to 1 hour, the direction of the airfl ow 

is  automatically  set  to  horizontal  position  to 

prevent water from condensing and dripping.

•  In  the  heating  operation,  if  the  airfl ow  tem-

perature is too low or when defrosting is being 

done, the horizontal vane is automatically set 

to horizontal position.

The operation stops for about 

10 minutes in the heating 

operation.

•  Outdoor unit is in defrost.

  Since  this  is  completed  in  max.10  minutes, 

please wait. (When the outside temperature is too 

low and humidity is too high, frost is formed.)

The unit starts operation by 

itself when the main power is 

turned on, but hasn’t received 

sign from the remote control-

ler.

•  These  models  are  equipped  with  an  auto 

restart  function.  When  the  main  power  is 

turned  off  without  stopping  the  unit  with  the 

remote controller and is turned on again, the 

unit starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function” 

 page 4 

.

The two horizontal vanes 

touch each other. The hori-

zontal vanes are in an abnor-

mal position. The horizontal 

vanes do not return to the 

correct “close position”.

Perform one of the following: 

•  Turn off and on the breaker. Make sure the horizon-

tal vanes move to the correct “close position”.

•  Start and stop the emergency cooling operation 

and make sure the horizontal vanes move to the 

correct “close position”.

In COOL/DRY mode, when the 

room temperature reaches near 

the set temperature, the outdoor 

unit stops, then the indoor unit 

operates at low speed.

•  When the room temperature deviates from the 

set temperature, the indoor fan starts running 

according to the settings on the remote control-

ler.

The indoor unit discolors over 

time.

•  Although plastic turns yellow due to the infl uence of 

some factors such as ultraviolet light and tempera-

ture, this has no effect on the product functions.

Multi system

The indoor unit which is not 

operating becomes warm and 

a sound, similar to water fl ow-

ing, is heard from the unit.

•  A  small  amount  of  refrigerant  continues  to 

fl ow into the indoor unit even though it is not 

operating.

When heating operation is 

selected, operation does not 

start right away.

•  When operation is started during defrosting of 

outdoor unit is done, it takes a few minutes (max. 

10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit 

does not rotate even though 

the compressor is running. 

Even if the fan starts to rotate, 

it stops soon.

•  When  the  outside  temperature  is  low  during 

cooling operation, the fan operates intermittently 

to maintain suffi cient cooling capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or pipe 

connecting sections are cooled and this causes 

water to condense.

•  In the heating operation, water condensed on 

the heat exchanger drips down.

•  In the heating operation, the defrosting operation makes 

ice forming on the outdoor unit melt and drip down.

White smoke is discharged 

from the outdoor unit.

•  In the heating operation, vapor generated by the 

defrosting operation looks like white smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear 

or it is dim. The indoor unit 

does not respond to the 

remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is  the  polarity  (+,  -)  of  the  batteries  correct?

 Page 3 

•  Are any buttons on the remote controller of other 

electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 

or heated suffi ciently.

•  Is  the  temperature  setting  appropriate? 

 Page 4 

•  Is the fan setting appropriate? Please change 

fan speed to higher setting. 

 Page 5 

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  Are there any obstacles blocking the air inlet or 

outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 

suffi ciently.

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 

in an insuffi cient cooling effect.

•  When the outside temperature is high, the cooling 

effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When the outside temperature is low, the heating 

effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow out 

warm air.

Airfl ow

The air from the indoor unit 

smells strange.

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it out 

with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in 

temperature.

“Burbling” sound is heard.

•  This  sound  is  heard  when  the  outside  air  is 

absorbed from the drain hose by turning on the 

range hood or the ventilation fan, making water 

fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows  into  the  drain  hose  in  case  the  outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off the 

fan or the compressor.

The sound of water fl owing 

is heard.

• This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is changed.

Timer

Weekly timer does not oper-

ate according to settings.

•  Is the ON/OFF timer set? 

 Page 6 

•  Transmit  the  setting  information  of  the  weekly 

timer to the indoor unit again. When the infor-

mation is successfully received, a long beep will 

sound from the indoor unit. If information fails to 

be received, 3 short beeps will be heard. Ensure 

information is successfully received. 

 Page 7 

•  When a power failure occurs and the main power 

turns  off,  the  indoor  unit  built-in  clock  will  be 

incorrect. As a result, the weekly timer may not 

work normally.

  Be  sure  to  place  the  remote  controller  where 

the  signal  can  be  received  by  the  indoor  unit.

 Page 3 

The unit starts/stops the 

operation by itself.

•  Is the weekly timer set? 

 Page 7 

In the following cases, stop using the air conditioner and consult your dealer.

•  When water leaks or drips from the indoor unit.

•  When the left operation indicator lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

SG79F596H01_en.indd   9

2011/03/15   7:56:28

Содержание MSZ-EF22VAB

Страница 1: ...MSZ EF42VAW MSZ EF50VAW MSZ EF22VAB MSZ EF25VAB MSZ EF35VAB MSZ EF42VAB MSZ EF50VAB MSZ EF22VAS MSZ EF25VAS MSZ EF35VAS MSZ EF42VAS MSZ EF50VAS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...ct handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell sto...

Страница 3: ...unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance which require sp...

Страница 4: ...s either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature b...

Страница 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Страница 6: ...ir flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Quiet Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction ...

Страница 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Страница 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Страница 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Страница 10: ...unning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips do...

Страница 11: ... the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such a...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F596H01 ...

Отзывы: