background image

En-1

● OPERATING INSTRUCTIONS ●

 WARNING

Do not connect the power cord to an intermediate point, use an ex-

tension cord, or connect multiple devices to a single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it securely 

into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do 

not apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote controller, 

make  sure  to  turn  the  breaker  OFF  or  disconnect  the  power 

plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause fi re, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure 

that no substance other than the specifi ed refrigerant (R410A) 

enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnor-

mal pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that specifi ed for the system 

will cause mechanical failure, system malfunction, or unit break-

down. In the worst case, this could lead to a serious impediment 

to securing product safety.

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appli-

ance by a person responsible for their safety.
Children should be supervised to ensure that they do not play 

with the appliance.

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

Be sure to receive a guarantee card from your dealer and check that the 

purchased data and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

  

Do not insert your fi nger, a stick, or other objects into the air 

inlet or outlet.

•  This may cause injury, since the fan inside rotates at high speeds 

during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or turn 

the breaker OFF.

•  A continued operation in the abnormal state may cause a malfunc-

tion, fi re, or electric shock. In this case, consult your dealer.

When the air conditioner does not cool or heat, there is a pos-

sibility of refrigerant leakage. In this case, consult your dealer. 

If a repair involves recharging the unit with refrigerant, ask the 

service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, it does 

not leak. However, if refrigerant leaks and comes in contact with 

a heat source such as a fan heater, kerosene heater, or cooking 

stove, it will create a harmful gas.

The user should never attempt to wash the inside of the indoor 

unit. Should the inside of the unit require cleaning, contact 

your dealer.

•  Unsuitable detergent may cause damage to plastic material inside 

the unit, which may result in water leakage. Should detergent 

come in contact with electrical parts or the motor, it will result in 

a malfunction, smoke, or fi re.

 CAUTION

Do not touch the air inlet or the aluminum fi ns of the indoor/

outdoor unit.

•  This may cause injury.

Do not use insecticides or fl ammable sprays on the unit.

•  This may cause a fi re or deformation of the unit.

Do not expose pets or houseplants to direct airfl ow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the 

indoor/outdoor unit.

•  Water may drip down from the unit, which may cause damage 

or malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your fi nger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

3

 PREPARATION BEFORE OPERATION 

3

 SELECTING OPERATION MODES 

4

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

5

 I-SAVE OPERATION  

6

 ECONO COOL OPERATION  

6

 TIMER OPERATION (ON/OFF TIMER) 

6

 WEEKLY TIMER OPERATION 

7

 CLEANING 

8

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

9

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

10

 INSTALLATION PLACE AND ELECTRICAL WORK 

10

 SPECIFICATIONS 

10

SG79F596H01_en.indd   1

2011/03/15   7:56:03

Содержание MSZ-EF22VAB

Страница 1: ...MSZ EF42VAW MSZ EF50VAW MSZ EF22VAB MSZ EF25VAB MSZ EF35VAB MSZ EF42VAB MSZ EF50VAB MSZ EF22VAS MSZ EF25VAS MSZ EF35VAS MSZ EF42VAS MSZ EF50VAS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...ct handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell sto...

Страница 3: ...unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance which require sp...

Страница 4: ...s either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature b...

Страница 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Страница 6: ...ir flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Quiet Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction ...

Страница 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Страница 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Страница 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Страница 10: ...unning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips do...

Страница 11: ... the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such a...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F596H01 ...

Отзывы: