● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?
•  Is the power supply plug connected?
•  Is the ON timer set? 

 Page 7 

The unit cannot be operated 
for about 3 minutes when 
restarted.

•  This protects the unit according to instruc-

tions from the microprocessor. Please 
wait.

Mist is discharged from the air 
outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 
into mist.

The swing operation of the 
HORIZONTAL / VERTICAL 
VANE is suspended for a 
while, then restarted.

•  This is for the swing operation of the HORI-

ZONTAL / VERTICAL VANE to be performed 
normally.

The air fl ow direction changes 
during operation.
The direction of the horizontal 
vane cannot be adjusted with 
the remote controller.

•  When the unit is operated in COOL or DRY 

mode, if the operation continues with air 
blowing down for 0.5 to 1 hour, the direction 
of the air fl ow is automatically set to position 
(1) to prevent water from condensing and 
dripping.

•  In the heating operation, if the air fl ow tem-

perature is too low or when defrosting is be-
ing done, the horizontal vane is automatically 
set to horizontal position.

The operation is stopped for 
about 10 minutes in the heat-
ing operation.

• Defrosting of the outdoor unit is being 

done.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 
is too low and humidity is too high, frost is 
formed.)

The unit starts operation by 
itself when the main power 
is turned on, though it isn’t 
operated with the remote 
controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 
off without stopping the unit with the remote 
controller and is turned on again, the unit 
starts operation automatically in the same 
mode as the one set with the remote control-
ler just before the shutoff of the main power. 
Refer to “Auto restart function” 

 Page 5 

.

The indoor unit discolors over 
time.

•  Although plastic turns yellow due to the infl u-

ence of some factors such as ultraviolet light 
and temperature, this has no effect on the 
product functions.

Outdoor Unit

The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.

• When the outside temperature is low dur-

ing cooling operation, the fan operates 
intermittently to maintain suffi cient cooling 
capacity.

Water leaks from the outdoor 
unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 
causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In the heating operation, the defrosting op-

eration makes water frozen on the outdoor 
unit melt and drip down.

White smoke is discharged 
from the outdoor unit.

• In the heating operation, vapor generated 

by the defrosting operation looks like white 
smoke.

Remote controller

The display on the remote 
controller does not appear or 
it is dim. The indoor unit does 
not respond to the remote 
control signal.

•  Are the batteries exhausted? 

 Page 4 

•  Is the polarity (+, -) of the batteries correct?

 Page 4 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Symptom

Explanation & Check points

Does not cool or heat

The room cannot be cooled 
or heated suffi ciently.

• Is the temperature setting appropriate? 

 Page 5 

• Is the fan setting appropriate? Please 

change fan speed to higher setting.

 Page 6 

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 
suffi ciently.

• When a ventilation fan or a gas cooker is 

used in a room, the cooling load increases, 
resulting in an insuffi cient cooling effect.

• When the outside temperature is high, the 

cooling effect may not be suffi cient.

The room cannot be heated 
suffi ciently.

• When the outside temperature is low, the 

heating effect may not be suffi cient.

Air does not blow out soon in 
the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airfl ow

The air from the indoor unit 
smells strange.

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 
out with the air.

Sound

Cracking sound is heard.

• This sound is generated by the expansion/

contraction of the front panel, etc. due to 
change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 
the range hood or the ventilation fan, making 
water fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 
wind is strong.

Mechanical sound is heard 
from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 
is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 
heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your 
dealer.

•  When water leaks or drips from the indoor unit.
•  When the left operation indicator lamp blinks.
•  When the breaker trips frequently.
•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Содержание MSZ-D30NA

Страница 1: ...ions before use MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento NOTICE D UTILISATION A l attention des clients Pour avoir la certitude d utiliser cet appareil correctement et en toute sécurité veuillez lire cette notice d instructions avant de mettre le clima tiseur sous tension Français ...

Страница 2: ...gth of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relo...

Страница 3: ...the battery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if ...

Страница 4: ...ived Operation display section ON OFF operate stop button Operation select button Page 5 ECONO COOL button Page 7 FAN speed control button Page 6 VANE control button Page 6 Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are inst...

Страница 5: ...er supply plug into the power outlet and or turn the breaker on Installing the remote controller batteries PREPARATION BEFORE OPERATION Press CLOCK gently using a thin instrument Setting current time Changing temperature units ºF ºC Unit is preset with ºF 1 Press RESET while the temperature but tons are pressed Press RESET gently using a thin instrument To change temperature unit from C to F press...

Страница 6: ...operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or...

Страница 7: ...ow direction in the following order Vertical airflow direction AUTO The vane is set to the most efficient airflow direction COOL DRY horizontal position HEAT downward position Manual For efficient air conditioning select upper position for COOL DRY and lower position for HEAT During COOL DRY when the vane is set to position 4 or 5 the vane automatically moves to position 1 after 0 5 to 1 hour to pre...

Страница 8: ... set the timer ON timer The unit will turn ON at the set time OFF timer The unit will turn OFF at the set time or blinks Make sure that the current time is set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Press or again to cancel timer Note ON and OFF timers can be set together mark indicates the order of timer...

Страница 9: ...e dirt by a vacuum cleaner or rinse with water After washing with water dry it well in shade What is Catechin air filter Catechin is a bioflavonoid that is found in green tea that has both antivi ral and antioxidant qualities In addition to these benefits Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent t...

Страница 10: ...g op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 4 Is the p...

Страница 11: ... 1m or more The installation location of the outdoor unit should be at least 10ft 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 ...

Страница 12: ...o durante un periodo de tiempo prolongado Puede ser perjudicial para la salud El usuario no debe instalar cambiar de sitio desmontar alterar ni reparar la unidad Si no se maneja correctamente el acondicionador de aire puede causar fuego descarga eléctrica lesiones escape de agua etc Consulte con su distribuidor Si el cable de alimentación está dañado deberá ser susti tuido por el fabricante o su a...

Страница 13: ...gua limpia Si el líquido de la pila entra en contacto con los ojos lávelos a fondo con agua limpia y acuda a un médico de inmediato Asegúrese de que la zona está bien ventilada cuando la unidad esté en funcionamiento junto con un aparato de combustión Una ventilación inadecuada puede originar falta de oxígeno Coloque el disyuntor en OFF si oye truenos y hay posibilidad de que caigan rayos La unida...

Страница 14: ...uste del reloj CLOCK Página 4 Botón de reinicializa ción RESET Página 4 Tapa Deslícela hacia abajo para abrir Instale el soporte del con trolador remoto en un lugar en el que la unidad interior pueda recibir la señal Use únicamente el controlador remoto suministrado con la unidad No use otro controlador remoto Si dos o más unidades interiores están instaladas cerca unas de otras puede que la unida...

Страница 15: ...iente y o encienda el disyuntor Instalación de las pilas del controlador remoto PREPARACIÓN ANTES DE LA PUESTA EN MARCHA Pulse CLOCK temporizador suavemente utili zando un objeto en punta Ajuste de la hora actual Cambio de unidades de temperatura ºF ºC La unidad esta configurada por defecto con ºF 1 Pulse RESET reini ciar con los botones de temperatura pulsados Pulse RESET reiniciar suavemente util...

Страница 16: ...iente 3 Pulse o para ajustar la temperatura Cada pulsación eleva o disminuye la temperatura en 1 F 1 C Pulse para apagarlo Cuando vuelva a encenderlo se activará la misma configuración se leccionada si pulsa Función de reinicio automático En caso de que se produzca un corte en el suministro eléctrico o se apague la unidad mientras esté funcionando la Función de reinicio automático se activará auto...

Страница 17: ...rección vertical del aire AUTO El deflector se ajusta en la dirección con mayor rendimiento de la dirección del aire REFRIGERACIÓN DESHUMIDIFICACIÓN posición horizontal CALEFACCIÓN posición hacia abajo Manual Para un mejor rendimiento del acondicionador de aire seleccione la posición superior para REFRIGERACIÓN DESHUMIDIFICACIÓN y la posición inferior para CALEFACCIÓN Durante los modos de REFRIGERA...

Страница 18: ...rante la configuración en AUTO auto mático La temperatura no puede configurarse mientras está funcionando en POWERFUL potente Vuelva a pulsar para cancelar el modo POWER FUL potente El funcionamiento en POWERFUL potente también se cancela au tomáticamente en 15 minutos o bien cuando se pulsan los botones ON OFF encendido apagado FAN ventilador o ECONO COOL desconexión automática FUNCIONAMIENTO POW...

Страница 19: ... aspirador Sumerja el filtro y su carcasa en agua emplada antes de enjuagarlos Puede utilizar detergentes suaves diluidos si no puede eliminar la suciedad Después de limpiarlo con agua déjelo secar completamente a la sombra Instale todas las pestañas del filtro de aire Cada año Cambie el filtro de aire por uno nuevo para un mejor rendimiento Número de las piezas MAC 1415FT E Filtro de aire filtro de a...

Страница 20: ...carchado derrite el hielo adherido a la unidad exterior y el agua empieza a gotear Sale humo blanco de la unidad exterior En el modo de calefacción el vapor que se genera debido al funcionamiento de desescarchado tiene el aspecto de humo blanco Síntoma Explicación y puntos de comprobación Controlador remoto La pantalla del controlador remoto no aparece o se oscurece La unidad interior no responde ...

Страница 21: ... fluores cente manténgase lo más alejado posible wall etc Lámpara fluorescente de tipo inversor Mantenga un espacio suficiente para evitar distorsiones en imágenes o sonido 3 ft 1 m o más Radio 4 in 100 mm o más Sitio seco y bien ventilado 20 in 500 mm o más Televisión Teléfono inalám brico o portátil 10 ft 3 m o más 3 ft 1 m o más La unidad exterior debe instalarse por lo menos a 10 ft 3 m de las an...

Страница 22: ...r déplacer dé monter modifier ou tenter de réparer le climatiseur Toute manipulation incorrecte du climatiseur pourrait provo quer un risque d incendie d électrocution de blessure ou de fuite d eau etc Contacter un revendeur Si le cordon d alimentation est endommagé il doit être rem placé par le fabricant ou le service après vente du fabricant pour éviter tout risque potentiel Lors de l installatio...

Страница 23: ...ements les rincer abondamment à l eau claire Si du liquide alcalin entre en contact avec les yeux les rincer abondamment à l eau claire et contacter d urgence un méde cin Si le climatiseur est utilisé conjointement avec un appareil à combustion veiller à ce que la pièce soit parfaitement ventilée Une ventilation insuffisante pourrait provoquer un manque d oxygène dans la pièce Couper le disjoncteur...

Страница 24: ...uche de réinitialisation RESET Page 4 Couvercle Le faire coulisser vers le bas pour l ouvrir Installez le support de la télécommande de façon à ce que l unité interne puisse recevoir les signaux Utilisez uniquement la télécommande fournie avec le climatiseur N en utilisez pas d autres Si plusieurs unités internes sont installées côté à côte il se peut que le signal envoyé à une unité interne par l...

Страница 25: ...ez le disjoncteur Insertion des piles dans la télécommande PREPARATIF D UTILISATION Appuyez doucement sur CLOCK à l aide d un instrument fin Réglage de l heure Changement des unités de température ºF ºC L unité prédéfinie est ºF 1 Appuyez sur RESET lorsque vous enfon cez les touches de température Appuyez doucement sur RESET à l aide d un instrument fin Pour changer l unité de la température entre de...

Страница 26: ...e nouvelle pression sur ces touches vous per met d augmenter ou de diminuer la température de 1 F 1 C Appuyez sur la touche pour arrêter le fonctionne ment du climatiseur Vous avez la possibilité de recouvrer les mêmes réglages lors de la prochaine utilisation du climatiseur en appuyant simplement sur Fonction de redémarrage automatique En cas de coupure d électricité ou d interruption de l alimen...

Страница 27: ...modifier la direction du flux d air dans l ordre suivant AUTO Faible Moy Elevée AUTO 1 2 3 4 5 OSCILLATION Direction du flux d air verticale AUTO L ailette se place de façon à ce que la direction du flux d air soit la plus efficace possible REFROIDISSEMENT DESHUMIDIFICATION position horizontale CHAUFFAGE orientation vers le bas Manuel Pour obtenir une climatisation efficace l ailette doit être dirigée...

Страница 28: ...mée de 10 minutes Appuyez à nouveau sur les touches ou pour annuler le fonctionnement de la minuterie Remarque Les fonctions de démarrage ON et d arrêt OFF de la minuterie peuvent être réglées conjointement Le symbole indique l ordre d application des modes de fonctionnement de la minuterie En cas de coupure d électricité survenant après le réglage de la minuterie MARCHE ARRET voir Page 5 Fonction...

Страница 29: ...re Lorsque cela ne suffit pas Faites tremper le filtre et son cadre dans de l eau tiède avant de les nettoyer Il est possible d utiliser des détergents doux dilués lorsqu il est impos sible d ôter la saleté Après lavage laisser bien sécher à l ombre Posez toutes les attaches du filtre à air Tous les ans Pour des performances optimales remplacer le filtre d épuration d air Référence MAC 1415FT E Filtre...

Страница 30: ...ésente sur l unité externe et celle ci se met à goutter De la fumée blanche sort de l unité externe En mode de chauffage la vapeur générée par l opération de dégivrage peut ressembler à de la fumée blanche Télécommande Aucun affichage sur la télécommande ou affichage indistinct L unité interne ne répond pas au signal de la télécommande Les piles sont elles déchargées Page 4 La polarité des piles est...

Страница 31: ...ur d une lampefluorescentepour éviter tout parasitage mur etc Lampes fluorescentes à oscillateur intermittent Maintenez un espace suffisant pour éviter toute distorsion de l image ou du son Radio 4 in 100 mm minimum Endroit sec et bien aéré 20 in 500 mm minimum TV Télé phone sans fil ou téléphone portable 10 ft 3 m minimum 3 ft 1 m minimum L unité externe doit être installée à 10 ft 3 m mi nimum des a...

Страница 32: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A063H04 ...

Отзывы: