23
1. troubleshooting check table
Operation Indicator
❈
Before taking measures, make sure that the symptom reappears, for accurate troubleshooting.
Self check table
NO.
1
2
3
4
Abnormal
point
Mis-wiring
Serial
signal
Indoor coil
thermistor
Room
temperatur
e
thermistor
Indoor fan
motor
Defrost
thermistor
Indication
0.5-second ON
0.5-second OFF
1-time flash
2.5-second OFF
2-time flash
2.5-second OFF
3-time flash
2.5-second OFF
6-time flash
2.5-second OFF
Symptom
Outdoor unit
does not run.
Outdoor unit
does not run.
Indoor fan motor
repeats 12
seconds ON and
3 minutes OFF.
When the indoor
fan breaks, the
fan motor keeps
stopping.
Outdoor unit
does not run
Detect method
When serial signal stops for 4
to 5 seconds after 1st on of
52C relay by POWER turning
on.
When serial signal from
outdoor unit stops for 4 to 5
seconds.
Detect Indoor coil/room
temperature thermistor short
or open circuit every 8
seconds during operation.
When rotational frequency
feedback signal is not emit
during 12-second indoor fan
operation.
When the defrost thermistor
shorts or opens after the
compressor start-up.
Check point
●
Check wiring (visual check and
conductivity check).
●
Check indoor electronic control
P.C.board.
●
Check outdoor DEICER P.C. board.
●
Check electrical parts.
●
Check resistance of thermistor.
●
Reconnect connector.
●
Check indoor electronic control P.C.board.
●
Disconnect connector CN211 and then
check connector CN121 - to make
sure rotational frequency feedback signal
of 1.5V or over exists.
●
Check indoor electronic control P.C.
board.
●
Check indoor fan motor.
●
Reconnect connector.
●
Check outdoor DEICER P.C. board.
●
Check resistance of thermistor.
●
Reconnect connector.
2
3
5
Outdoor
power
system
5-time flash
2.5-second OFF
Outdoor unit
does not run
When the compressor
operation is continuously three
times interrupted by over
current protection within 1
minute after start-up , it stops
operation.
●
Check the inverter output.
●
Check the compressor.
6
Outdoor
control
P.C. board
7-time flash
2.5-second OFF
Outdoor unit
does not run
The outdoor unit stops
operation when it cannot
properly read data in the
nonvolatile memory of the
outdoor control P.C.board.
●
Check the outdoor control P.C.board.
7
Outdoor
control
P.C. board
10-time flash
2.5-second OFF
Outdoor unit
does not run
When the indoor unit detects
drain abnormality and the
indoor coil temperature is too
low.
●
Check the drain pump.
●
Check the drain sensor.
●
Check LEV.
Operation Indicator
8
Outdoor
control
P.C. board
lighting 2.5-second OFF
flashing
Outdoor unit
runs but the
indoor unit does
not run.
When the operation mode of
each rooms is set
COOL(includes DRY) and
HEAT at same time, it take
precedence the operation
mode runs first.
●
Adjust the operation mode.
❈
❈
❈
❈
❈
The indication is shown only when the indoor unit connects with the outdoor unit MXZ-32NV-
or MXZ-32NV-
or
MXZ-32RV-
.
E1
E2