27
PHOTOS
3. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1)
(2) Disconnect the connector remove the hooked lead wire
from the fan motor.
(3) Remove the propeller nut and remove the propeller fan.
(4) Remove screws securing the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor
(4) Disconnect lead wires from the glass terminal of the
compressor.
(5) Release gas from the refrigerant circuit.
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(8) Remove nuts fixing the compressor.
(9) Remove the compressor.
Photo 5
Compressor
Discharge
pipe
Suction
pipe
Compressor set nuts
Photo 4
Hook
Connector
Propeller fan
Propeller fan nut
Soundproof felt
OPERATING PROCEDURE