10-2. Instruction of troubleshooting
Indoor unit
operates. Outdoor
unit doesn’t
Outdoor unit
operates in
only Test
Run
operation.
Outdoor unit
doesn’t
operate even
in Test Run
operation.
Check room
temperature
thermistor.
Refer to
“Check of
outdoor unit”
on page 22.
Indoor unit doesn’t
receive the signal
from remote
controller.
Refer to “Check
of remote controller
and receiver P.C.
board” on page 21.
Operation Indicator lamp
on the indoor unit is
flashing on and off.
Indoor unit doesn’t
receive the signal from
remote controller.
Also, Operation Indicator
lamp doesn’t flash, when
the EMERGENCY
OPERATION switch is
pressed.
Refer to “Check of
indoor electronic control
P.C. board” on page 22.
Cause:Indoor unit
2-time-Room temperature/Indoor coil thermistor trouble
3-time-Indoor fan motor trouble
D
B
Check room temperature
thermistor. Refer to“Test
point diagram and
voltage” on page 23.
Refer to
“Check of indoor
fan motor” on
page 21.
Check indoor coil
thermistor. Refer
to“Test point
diagram and
voltage” on page
23.
2-time flash
2.5-second OFF
3-time flash
2.5-second OFF
Start
C
A
1. troubleshooting check table
Operation Indicator
w
Before taking measures, make sure that the symptom reappears for accurate troubleshooting.
Self check table
NO.
1
2
Abnormal
point
Indoor coil
thermistor
Room
temperatur
e
thermistor
Indoor fan
motor
Indication
2-time flash
2.5-second OFF
3-time flash
2.5-second OFF
Symptom
Outdoor unit
does not run.
Indoor fan motor
repeats 12
seconds ON and
3 minutes OFF.
When the indoor
fan motor
breaks, the fan
keeps stopping.
Detect method
Detect Indoor coil/room
temperature thermistor short
or open circuit every 8
seconds during operation.
When rotational frequency
feedback signal is not emit
during 12-second indoor fan
operation
Check point
●
Check thermistor calibration.
●
Reconnect connector.
●
Check indoor electronic control P.C.
board.
●
Disconnect connector CN211 and then
check connector CN121
2
-
3
to make
sure rotational frequency feedback signal
of 1.5V or over exists.
●
Check indoor electronic control P.C.
board.
●
Check indoor fan motor.
●
Reconnect connector.