21
Replace the receiver P.C. board.
Replace the remote controller.
Replace the batteries.(See page 18.)
Switch on the remote controller.
Repair the indoor fan motor.
Resolder it.
Disconnect lead wires from connector CN211 on the indoor electronic control P.C. board.
Measure resistance between lead wires No.1 and No.4 and then No.1 and No.2.
Turn OFF the power supply.
Check connector CN211 visually.
Reconnect the lead wires.
Yes
Yes
Check of indoor fan motor
A
Check of remote controller and receiver P.C. board
B
Indoor fan does not operate.
Are lead wires connected?
Is soldered point normal?
Insert screwdriver into air outlet to rotate indoor fan
motor slowly for 1 revolution or over, and measure
voltage No.2(+) and No.3(-) on CN121.
Is resistance 0 (short circuit) or
°
(open circuit)?
Indoor unit operates by pressing the EMERGENCY OPERATION switch, but does not operate with the remote controller.
Turn on a radio to AM and press switch on
the remote controller.
Is noise heard from radio?
Are there any fluorescent lights of
inverter or rapid-start type within
the range of 1m?
Turn ON the power supply.
Measure the voltage between receiver P.C. board connector No.2
(+)
and No.1when remote controller button is
pressed.
Is the voltage approx. 4V DC?
Replace the indoor electronic control P.C.
board.
●
Re-install the unit away from lights.
●
Attach a filter on receiving part.
Yes ( 0 or
°
)
No
(others)
Yes
No
Yes
No
Is LCD display on the remote
controller visible?
Remove the batteries and then set them
back. Check if the unit operates with the
remote controller.
Yes
Does the unit operate with the
remote controller?
Yes
OK
No
(not clear)
Yes
No
No
No(5V or 0V DC)
No
w
Check if the remote controller is exclusive for this air conditioner.
Replace the indoor electronic control P.C. board.
Does voltage repeat 0V DC and 5V DC?
Yes
No