Cleaning
After Assembly
After Assembly
After Assembly
1
3
4
5
7
2
6
1
Connect the tank pipe to the water tank
and water supply pump.
Check that there are no foreign substances between
the tank pipe and the water tank, or between the
tank pipe and water supply pump.
2
Install the tank packing.
Install the tank pipe, tank packing,
lid, and tank cap.
Tank Packing
Do not let
a foreign
substance block
the hole.
Check that there are no
foreign substances.
3
Install the lid.
4
Install the tank cap.
Water Tank
Water Supply Pump
Tank Pipe
Caution
Pull out the tank pipe and
rotate the water supply
pump in the direction of
the arrow to remove it.
Remove the water tank,
and remove the lid and
tank cap.
When using bleach to clean the water
tank and lid, follow the product
instructions.
Water Supply Pump
Mold, water scale, and other contamination form easily
in certain types of water. If this occurs, clean 2 or 3 times
a week.
* Drain the water out when you will not be making ice.
Turn the tank
cap to remove it.
After Assembly
4
Rotate the cap and hook the tab (
) onto
the projection (
) on the impeller holder.
Make sure that the impeller is inside.
Rotate
2
Fit the cap lid onto
the cap.
3
Install the impeller
into the impeller
holder.
1
Fit the chlorine-cleaning
filter into the cap.
* The chlorine-cleaning filter
does not have a front side or
back side.
5
Rotate the water supply
pump and install it onto
the water tank.
Align the triangle mark on the
bottom of the water tank with
the triangle mark on the cap
lid and push the water supply
pump in securely so there is
no gap.
Tank Pipe
Water Tank and Water Supply Pump
Once a week
Cleaning the Automatic Ice Maker
Water Tank
Tank
Packing
Water Tank
Lid
Tank Cap
Perform cleaning periodically to prevent
mold, water scale, and other contamination.
Pull out the tank packing
from the water tank.
Invert the water tank.
Assembling the water supply pump
Rotate
Disassemble the
water supply pump.
Open the tab and
remove the cap lid.
Wash each part with water.
Impeller
The impeller is made
from a magnet. Wash it
thoroughly to remove any
foreign substances.
Cap
Impeller
Holder
Cap Lid
Do not use a sponge, scrubber, or similar item when
cleaning. Scratches on the surface may cause malfunction.
Do not use a dishwasher, dryer, or hot water as these
may cause deformation.
Requests
Chlorine-Cleaning Filter
Wash while pressing on it gently.
* Do not use bleach or detergent.
Doing so may cause odors in the
ice.