background image

7

SUZ-KA18NA

RT

68

TR821

TB1,TB2

X63,X64,X66

21S4

T801

HEA

TER PROTECT

OR(OPTION P

AR

TS)

26H

DB61,DB65

C61,C62,C63

SYMBOL

NAME

SYMBOL

NAME

SYMBOL

NAME

DEFROST

 HEA

TER(OPTION P

AR

TS)

L61

IC802

IPM, HC930

H

F701,F801,F901

LED

LED

RT

65

RT

64

RT

62

RT

61

PTC64,PTC65

MF

MC

LEV

LED

1

1

22

1

2

(OPTION P

AR

TS)

YLW

RED

BLK

BLK

BLK

BLK

26H

BLK

BLK

2

1

H

BLK

CN722

3

1

X66

TO

 INDOOR UNIT

CONNECTING WIRES 208/230V 1 phase 60Hz

GROUND

FROM INDOOR UNIT CONNECTING WIRE

BLU

FROM INDOOR UNIT CONNECTING WIRES DC12-24V

POWER SUPPL

Y

208/230V 1 phase 60Hz

1

11

1

1

5

23

2

4

1

INVER

TER P

.C. BOARD

CN931

5

21S4

CN724

6

CN61

LDU

LDV

LDW

ORN

YL

W

BLU

BLK

WHT

RED

1

3

BLK

RED

WHT

U

W

MC

MF

LEV

MS

3~

MS

M

3~

V

1

3

IC802

V

U

IPM

W

N

P

3

1

HC930

T801

F801

TR821

DB65

DB61

LD66

LD70

C63

C62

C61

L61

CN932

CN644

CN642

RT

68

RT

64

L2

L1

TB1

TB2

S1

S2

S3

BRN

2

1

RED

BRN

BLU

CIRCUIT

 BREAKER

CN641

RT

61

RT

62

CN643

RT

65

3

X63

CN721

F901

6

LD61

LD62

LD-S

PTC65

LD-E1

BLK

PTC64

X64

F701 LD63

NOTES: 1. 

About the indoor side electric wiring refer to the indoor unit electric

   wiring diagram  for servicing.

2. Use copper conductors only

. (For field wiring).

~

+

+

++

+

~~

~

4

REACT

OR

DIODE MODULE

EXP

ANSION

VAL

VE COIL

COMPRESSOR

SMOOTHING CAP

ACIT

OR

FUSE (T3.15AL250V)

INTELLIGENT

 POWER DEVICE

INTELLIGENT

 POWER MODULE

FA

N MOTOR

CIRCUIT PROTECTION DEFROST THERMISTOR

DISCHARGE TEMP

.THERMISTOR

FIN TEMP

.THERMISTOR

AMBIENT TEMP

.THERMISTOR

OUTD

OOR HEA

T EXCHANGER

TEMP

. THERMISTOR.

TERMIN

AL BL

OCK

SWITCHING POWER TRANSISTOR

TRANSFORMER

RELA

Y

REVERSING

VAL

VE COIL

Содержание Mr.SLIM SUZ-KA09NA

Страница 1: ...ACTUATOR CONTROL 12 9 SERVICE FUNCTION 13 10 TROUBLESHOOTING 13 11 FUNCTION SETTING 29 12 DISASSEMBLY INSTRUCTIONS 32 HFC utilized R410A January 2010 R410A Outdoor unit Model names Service Ref SUZ KA09NA SUZ KA09NA TH SUZ KA12NA SUZ KA12NA TH SUZ KA15NA SUZ KA15NA TH SUZ KA18NA SUZ KA18NA TH NOTE This service manual describes service data of the outdoor units RoHS compliant products have G mark on...

Страница 2: ...rain hose Drain outlet Air inlet back and side SUZ KA18NA PART NAMES AND FUNCTIONS 2 SUZ KA09NA SUZ KA12NA SUZ KA15NA Heat pump type Outdoor unit SUZ SEZ KD15NA TH SEZ KD18NA TH Indoor unit Service Manual No Service Ref Heat pump without electric heater KA18NA TH KA15NA TH HWE08020 KA12NA TH KA09NA TH SEZ KD09NA TH SEZ KD12NA TH OUTDOOR UNIT ...

Страница 3: ...3 7 16 Weight Ib 66 77 80 119 External finish Munsell 3Y 7 8 1 1 Control voltage by built in transformer VDC 12 24 Refrigerant piping Not supplied Refrigerant pipe size Min wall thickness Liquid in 1 4 0 0315 Gas in 3 8 0 0315 1 2 0 0315 Connection method Indoor Flared Outdoor Flared Between the indoor outdoor units Height difference ft 40 50 Piping length ft 65 100 Refrigerant charge R410A 1 lb 1...

Страница 4: ...es of the unit 14 in or more 8 in or more 4 in or more 4 in or more Open two sides of left right or rear side SUZ KA18NA 20 9 32 14 3 16 Air in 11 25 32 2 19 32 Air in Air out 19 11 16 33 1 16 13 2 4 25 32 33 7 16 16 15 16 3 3 16 4 3 8 13 16 slot 1 11 32 1 9 16 Drain 3 holes ø1 5 16 3 0 3 5 2 9 16 Liquid 1 4 flared Gas 1 2 flared 3 9 16 8 11 32 Open as a rule 20 inch or more if the front and both ...

Страница 5: ...1 6 INVERTER P C BOARD 3 F901 BLU CN721 X63 2 1 1 RT65 CN643 RT62 RT61 CN641 4 1 CIRCUIT BREAKER BRN BLU BRN RED 1 2 S3 S2 S1 TB2 TB1 RT64 RT68 CN642 CN644 2 1 CN932 L61 C62 C63 LD70 LD66 DB61 DB65 TR821 F801 T801 1 3 P N W U V IC802 3 1 V W MS 3 MS MF 3 M LEV MC IPM U WHT RED BLK 3 1 RED WHT BLK BLU YLW ORN LDW LDV LDU CN61 6 CN724 1 21S4 1 1 2 2 1 OPTION PARTS YLW BLK BLK BLK BLK 1 H BLK CN722 3...

Страница 6: ... 60Hz TO INDOOR UNIT CONNECTING WIRES 208 230V 1 phase 60Hz From INDOOR UNIT CONNECTING WIRES DC12 24V LD63 F701 X64 PTC64 BLK LD E1 PTC65 LD S LD62 LD61 6 3 BLU CN721 2 1 1 RT65 CN643 RT62 RT61 CN641 4 1 CIRCUIT BREAKER BRN BLU BRN RED 1 2 S3 S2 S1 TB2 TB1 RT64 RT68 CN642 CN644 2 1 L61 T801 1 IC802 BLU YLW ORN 6 CN724 1 21S4 1 1 2 2 1 OPTION PARTS YLW BLK BLK BLK BLK 1 H BLK CN722 3 1 X63 X66 4 t...

Страница 7: ...T U W MC MF LEV MS 3 MS M 3 V 1 3 IC802 V U IPM W N P 3 1 HC930 T801 F801 TR821 DB65 DB61 LD66 LD70 C63 C62 C61 L61 CN932 CN644 CN642 RT68 RT64 L2 L1 TB1 TB2 S1 S2 S3 BRN 2 1 RED BRN BLU CIRCUIT BREAKER CN641 RT61 RT62 CN643 RT65 3 X63 CN721 F901 6 LD61 LD62 LD S PTC65 LD E1 BLK PTC64 X64 F701 LD63 NOTES 1 About the indoor side electric wiring refer to the indoor unit electric wiring diagram for s...

Страница 8: ...68 Service port Service port Muffler SUZ KA12NA SUZ KA15NA Outdoor heat exchanger Flared connection Defrost thermistor RT61 Discharge temperature thermistor RT62 Flared connection Stop valve with strainar Stop valve with service port Refrigerant flow in cooling Compressor 4 way valve Refrigerant flow in heating Refrigerant pipe ø3 8 KA12 Refrigerant pipe ø1 2 KA15 with heat insulator Refrigerant p...

Страница 9: ... 2 with heat insulator Refrigerant pipe ø1 4 with heat insulator LEV R V coil heating ON cooling OFF Muffler 100 Receiver Outdoor heat exchanger temperature thermistor RT68 Ambient temperature thermistor RT65 Strainer 100 Service port Service port Max Length A Max Height difference B Indoor unit Outdoor unit MAX REFRIGERANT PIPING LENGTH and MAX HEIGHT DIFFERENCE Model Refrigerant piping ft Piping...

Страница 10: ...0 1 62 4 86 8 10 11 34 12 96 SUZ KA12NA 2 lb 9 oz SUZ KA15NA Calculation X oz 1 62 5 oz ft Refrigerant piping length ft 25 Model Outdoor unit precharged Refrigerant piping length one way ft 25 30 40 50 60 70 80 90 100 SUZ KA18NA 3 lb 16 oz 0 1 08 3 24 5 40 7 56 9 72 11 88 14 04 16 20 Calculation X oz 1 08 5 oz ft Refrigerant piping length ft 25 NOTE Refrigerant piping exceeding 25 ft requires addi...

Страница 11: ...KA12NA SUZ KA15NA SUZ KA18NA Power supply V phase Hz 230 1 60 Input kW 0 61 0 98 0 85 1 09 1 08 1 43 1 29 1 63 Current A 2 80 4 33 3 64 4 65 4 45 5 96 5 38 6 91 Refrigerant circuit Condensing pressure PSIG 398 448 387 386 399 389 373 397 Suction pressure PSIG 135 97 135 104 133 96 142 100 Discharge temperature F 148 170 162 165 159 182 150 172 Condensing temperature F 116 125 114 114 116 115 112 1...

Страница 12: ... stopped running ON OFF Compressor Outdoor fan motor R V coil ON OFF ON OFF COOL 5 seconds HEAT 5 seconds 8 3 RELATION BETWEEN MAIN SENSOR AND ACTUATOR Sensor Purpose Actuator Compressor LEV Outdoor fan motor R V coil Indoor fan motor Discharge temperature thermistor Protection Indoor coil temperature thermistor Cooling Coil frost prevention Heating High pressure protec tion Defrost thermistor Hea...

Страница 13: ...wing 1 Check the power supply voltage 2 Check the indoor outdoor connecting wire for miswiring 2 Take care of the following during servicing 1 Before servicing the air conditioner be sure to turn OFF the main unit first with the remote controller and turn off the breaker 2 Be sure to turn OFF the power supply before removing the front panel the cabinet the top panel and the electronic control P C ...

Страница 14: ...ween indoor and outdoor units P8 Pipe temperature error E4 E5 Remote controller signal receiving error Fb Indoor unit control system error memory error etc E1 E2 Remote controller control board error E0 E3 Remote controller transmission error Output pattern B Errors detected by unit other than indoor unit outdoor unit etc Check code Symptom Remark E9 Indoor outdoor unit communication error Transmi...

Страница 15: ...AT mode Temperature of outdoor heat exchanger temperature thermistor exceeds 158 F 70 C in COOL mode Check refrigerant circuit and refrigerant amount Check stop valve Fin temperature P C board temperature 7 time flash 2 5 seconds OFF Temperature of fin temperature thermistor on the inverter P C board exceeds 167 176 F 75 80 C or temperature of P C board temperature thermistor on the inverter P C b...

Страница 16: ...p valve 11 8 time flash 2 5 seconds OFF Compressor syn chronous abnormal ity The waveform of compressor current is distorted Reconnect connector of compressor Refer to 10 5 How to check inverter compressor 12 10 time flash 2 5 seconds OFF Outdoor fan motor Outdoor fan has stopped 3 times in a row within 30 seconds after outdoor fan start up Refer to 10 5 Check of outdoor fan motor Refer to 10 5 Ch...

Страница 17: ...r to 10 6 Test point diagram and voltage 1 Inverter P C board for the chart of thermistor Compressor Measure the resistance between terminals with a tester Temperature 14 104 F 10 40 C Normal Ω KA09 KA12 KA15 18 U V U W V W 1 36 1 93 1 52 2 17 0 78 1 11 Outdoor fan motor Measure the resistance between lead wires with a tester Temperature 14 104 F 10 40 C Color of lead wire Normal Ω KA09 12 15 KA18...

Страница 18: ...tton and switch to the COOL or HEAT mode 3 Compressor starts at rated frequency in COOL mode or 58 Hz in HEAT mode 4 Indoor fan operates at High speed 5 To cancel test run operation press the ON OFF button on remote controller Measurement point at 3 points BLK U WHT V BLK U RED W WHT V RED W NOTE 1 Output voltage varies according to power supply voltage 2 Measure the voltage by analog type tester ...

Страница 19: ...rcuit check Contact of the compressor connector including CN61 Output voltage of inverter P C board and balance of them See 10 5 Direct current voltage between DB61 and on the inverter P C board Voltage between outdoor terminal block S1 S2 1 2 3 4 1 Heat the compressor with a drier for about 20 minutes Do not recover refrigerant gas while heating Heating part Connect the compressor and activate th...

Страница 20: ... In case CN721 is disconnected or R V coil is open voltage is generated between the terminal pins of the connector although no signal is being transmitted to R V coil Check if CN721 is connected Is there 208 230 VAC between CN721 and on the inverter P C board 3 minutes after the power supply is turned ON No Yes Replace the inverter P C board Replace the 4 way valve Unit operates COOL mode even if ...

Страница 21: ...utdoor fan motor normal Refer to 10 4 Check the connection between the connector CN931 and CN932 Disconnect CN932 from the inverter P C board and turn on the power supply Rotate the outdoor fan motor manually and measure the voltage of CN931 Between 1 and 5 Between 2 and 5 Between 3 and 5 Does the voltage between each terminal become 5 and 0 VDC repeatedly Does the outdoor fan motor rotate smoothl...

Страница 22: ...mote controller light up Does LED on the inverter P C board light up or flash Refer to 10 6 1 No Replace the inverter P C board Is there bus bar voltage 260 325 VDC between DB61 and DB61 on the inverter P C board Refer to 10 6 1 No Check the electric parts in main circuit Yes Yes No Disconnect the connector CN61 between compressor and intelligent power module Turn ON power supply and press the TES...

Страница 23: ...ch voltage between connector pins of CN724 on the inverter P C board 1 Pin Pin 2 Pin Pin 3 Pin Pin 4 Pin Pin Is there about 3 5 VAC between each NOTE Measure the voltage with an analog tester Properly fix the LEV coil to the expansion valve Replace the LEV coil Replace the expansion valve Is LEV coil properly fixed to the expansion valve Does the resistance of LEV coil have the characteristics Ref...

Страница 24: ...tion of the connectors CN931 CN932 of the outdoor fan motor If the connection is poor make it correct Operate the outdoor unit by starting TEST RUN Check the LED indication on the in verter P C board Does the LED flash 10 times Replace the inverter P C board Check the remedy following LED indication Refer to 10 3 Yes No Yes 10 time flash No ...

Страница 25: ...of the residual voltage of smoothing capacitor Yes 3 Be sure to check this within 3 minutes after turning ON After 3 minutes LED blinks 6 times Even when the inverter P C board or the outdoor electronic control P C board is normal LED blinks 6 times after 3 minutes Is the bus bar voltage of the inverter P C board or the outdoor electronic control P C board normal Refer to TEST POINT DIAGRAM AND VO...

Страница 26: ...ength or the installation condition combination of specific conditions such as antennas or wiring Check the followings before asking for service 1 Devices affected by the electromagnetic noise TV sets radios FM AM broadcast shortwave 2 Channel frequency broadcast station affected by the electromagnetic noise 3 Channel frequency broadcast station unaffected by the electromagnetic noise 4 Layout of ...

Страница 27: ...UZ KA15NA 10 6 TEST POINT DIAGRAM AND VOLTAGE Back side of unit Fin temperature thermistor RT64 CN642 Ambient temperature thermistor RT65 CN643 Discharge temperature thermistor RT62 CN641 Defrost thermistor RT61 CN641 LEV connector CN724 Bus bar voltage DB61 DC 260 325 V Front side of unit AC 208 230 V Smoothing capacitor C62 Output to drive compressor LDU LDV LDW Fuse F701 T3 15 AL 250 V Smoothin...

Страница 28: ...f unit Fin temperature thermistor RT64 CN642 Ambient temperature thermistor RT65 CN643 Discharge temperature thermistor RT62 CN641 Defrost thermistor RT61 CN641 LEV connector CN724 Bus bar voltage DB61 DC 260 325 V Front side of unit AC 208 230 V Smoothing capacitor C62 Output to drive compressor LDU LDV LDW Fuse F701 T3 15 AL 250 V Smoothing capacitor C61 Smoothing capacitor C63 Fuse F801 250 V 3...

Страница 29: ...g is applied to all the units in the same refrigerant system Check 2 Functions are available when setting the unit number to 01 SEZ KD NA Function Settings No Mode No Setting Initial setting Factory setting Filter sign 100h 1 2500h 07 2 No filter sign indicator 3 External static pressure 5 15 35 50Pa 0 02 0 06 0 14 0 20in WG 08 10 1 2 Extra low 3 Fan speed during the heating thermo OFF Stop 25 1 S...

Страница 30: ... setting Press Specified indoor unit FAN operation Change refrigerant address or unit No Switch to function setting mode Press and at the same time with stop the remote controller 11 1 1 Selecting functions using the wired remote controller First try to familiarize yourself with the flow of the function selection procedure In this section an example of setting the room temperature detection positi...

Страница 31: ...desired setting No Confirm the settings made at the steps through Press the button to flash the mode No and setting No and to start registration The mode No and setting No stop flashing to confirm the settings If the mode No or setting No shows and the temperature shows this seems to be a transmission error Check for noise source or interference around the transmission path To make additional sett...

Страница 32: ... panel Service panel Screws of the top panel Screw of the cabinet Screws of the top panel Hooks Screw of the service panel Screw of the conduit cover Conduit plate Conduit cover 1 Slide the sleeve and check if there is a locking lever or not 2 The terminal with this connector has the locking mechanism Slide the sleeve Pull the terminal while pushing the locking lever Hold the sleeve and pull out t...

Страница 33: ...llowing connectors Inverter P C board CN721 R V coil 3 Remove the R V coil Photo 5 4 Removing the discharge temperature thermistor defrost thermistor outdoor heat exchanger tempera ture thermistor and ambient temperature thermistor 1 Remove the cabinet and panels Refer to 1 2 Disconnect the lead wire to the reactor and the following connectors Inverter P C board CN641 Defrost thermistor and discha...

Страница 34: ...abinet and panels Refer to 1 2 Remove the inverter assembly Refer to 2 3 Recover gas from the refrigerant circuit NOTE Recover gas from the pipes until the pressure gauge shows 0 PSIG 4 Detach the welded part of the suction and the discharge pipe connected with compressor 5 Remove the nuts of compressor legs 6 Remove the compressor 7 Detach the welded part of pipes connected with 4 way valve Photo...

Страница 35: ... Remove the top panel 6 Remove the valve cover 7 Disconnect the power supply and indoor outdoor connect ing wire 8 Remove the screws of the cabinet 9 Remove the cabinet 10 Remove the screws of the back panel 11 Remove the back panel Photo 1 Photo 2 Screws of the cabinet Screws of the back panel Screw of the top panel Screws of the cabinet Screws of the cabinet Screw of the valve cover Screw of the...

Страница 36: ...e inverter assembly Photo 4 6 Remove the screw of the ground wire and screw of the T B support Photo 4 7 Remove the screw of the PB fixture 8 Remove the relay panel from the PB support 9 Remove the inverter P C board from the inverter assembly Photo 3 Photo 4 Inverter assembly Photo5 3 Removing R V coil 1 Remove the cabinet and panels Refer to 1 2 Disconnect the following connectors Inverter P C b...

Страница 37: ... Removing outdoor fan motor 1 Remove the top panel cabinet and service panel Refer to 1 2 Disconnect the following connectors Inverter P C board CN931 and CN932 Fan motor 3 Remove the propeller 4 Remove the screws fixing the fan motor 5 Remove the fan motor 6 Removing the compressor and 4 way valve 1 Remove the top panel cabinet and service panel Refer to 1 2 Remove the back panel Refer to 1 3 Rem...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...RUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN CCopyright 2010 MITSUBISHI ELECTRIC ENGINEERING CO LTD Distributed in Jan 2010 No OCH467 PDF 4 Made in Japan New publication effective Jan 2010 Specifications subject to change without notice ...

Отзывы: